Surgical Instruments
Retractor Base
1manufacturer
1catalogue number
Who Else Makes It
Registered in Jiangsu. One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 10 |
Record
| Listed by | Smith & Nephew, Inc., United States |
|---|---|
| FDA product code | HSN |
| Device type | Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3110 |
| Establishment | Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K151459 |
| Record published | 2023-06-17 |
| Record revised | 2023-09-07 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Prescription | Prescription only |
| Label carries | lot or batch number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| CSA-925-01 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Apex 3D Total Ankle Replacement System | Paragon 28 | 658 |
| Vantage | Exactech, Inc. | 362 |
| Cadence™ | Ascension Orthopedics, Inc. | 248 |
| Cadence Total Ankle System | Smith & Nephew, Inc. | 246 |
| Inbone | Wright Medical Technology, Inc. | 236 |
| Hintermann Series H2 | DT Medtech LLC | 225 |
| Infinity | Wright Medical Technology, Inc. | 220 |
| Incompass Total Ankle System | Wright Medical Technology, Inc. | 213 |
| Invision | Wright Medical Technology, Inc. | 186 |
| Kinos Axiom Instrumentation | restor3d, inc. | 169 |
| Quantum | In2Bones SAS | 157 |
| Hintermann Series H2 | Vilex LLC | 153 |
Showing 12 of 53. All products under Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Integra Lifesciences Corporation | 510(k) number | 2017-01-20 | Class II | Use error | Posterior tibial fractures have been reported. | 944 units | 2017-03-30 |
| Integra Lifesciences Corporation | 510(k) number | 2016-04-29 | Class II | Labeling mix-ups | As a result of an internal review of all labeling for the Cadence System, it was determined that the outer package label for the Size 5 Left Tibial Tray Implant reflects the material composition incorrectly. The labeling incorrectly reflec | 12 units | 2016-10-19 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.