Trabecular Metal Ankle
Catalogue number SSI004659, listed by Zimmer, Inc., United States, under Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer. 1 manufacturer in China is registered for this product code.
Who Else Makes It
Registered in Jiangsu. One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 10 |
Record
| Listed by | Zimmer, Inc., United States |
|---|---|
| FDA product code | HSN |
| Device type | Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3110 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter |
| 510(k) | K120906 |
| Record published | 2018-08-28 |
| Record revised | 2023-05-03 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Prescription | Prescription only |
| Label carries | serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| SSI004659 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Apex 3D Total Ankle Replacement System | Paragon 28 | 658 |
| Vantage | Exactech, Inc. | 362 |
| Cadence™ | Ascension Orthopedics, Inc. | 248 |
| Cadence Total Ankle System | Smith & Nephew, Inc. | 246 |
| Inbone | Wright Medical Technology, Inc. | 236 |
| Hintermann Series H2 | DT Medtech LLC | 225 |
| Infinity | Wright Medical Technology, Inc. | 220 |
| Incompass Total Ankle System | Wright Medical Technology, Inc. | 213 |
| Invision | Wright Medical Technology, Inc. | 186 |
| Kinos Axiom Instrumentation | restor3d, inc. | 169 |
| Quantum | In2Bones SAS | 157 |
| Hintermann Series H2 | Vilex LLC | 153 |
Showing 12 of 53. All products under Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K120906 | 2012-08-24 |
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Zimmer, Inc. | 510(k) number | 2019-10-10 | Class II | Packaging change control | Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). | 5,459,583 total devices | 2020-05-19 |
| Zimmer, Inc. | 510(k) number | 2013-11-12 | Class II | Manufacturing material removal | As part of routine manufacturing process monitoring by Zimmer, it was discovered that the Tibial Base and Talar Components from the Total Ankle system have the potential of containing elevated levels of manufacturing materials residue on th | 269 units (US) 110 units (outside US) | 2014-10-15 |
| Zimmer, Inc. | 510(k) number | 2013-11-12 | Class II | Manufacturing material removal | As part of routine manufacturing process monitoring by Zimmer, it was discovered that the Tibial Base and Talar Components from the Total Ankle system have the potential of containing elevated levels of manufacturing materials residue on th | 265 units (US) 114 units (outside US) | 2014-10-15 |
| Zimmer, Inc. | 510(k) number | 2013-11-12 | Class II | Manufacturing material removal | As part of routine manufacturing process monitoring by Zimmer, it was discovered that the Tibial Base and Talar Components from the Total Ankle system have the potential of containing elevated levels of manufacturing materials residue on th | 390 units (US) 129 units (outside of US) | 2014-10-15 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.