ZUK

ZUK All-Poly Tibia Size 3 14mm Right Medial/Left Lateral

Registry build 21.09.26
6manufacturers in China registered for this device type
161catalogue numbers in this listing
13510(k) clearances naming this product code
40recalls on this code

Who Else Makes It

Concentrated in Zhejiang (2), Jiangsu (2), Shanghai (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HSX
Manufacturer City Province Registered as Device types
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Turnxon Precision Co., Ltd. Dongguan Guangdong Contract manufacturer 17
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74

Record

Regulatory record for ZUK
Listed by Smith & Nephew, Inc., United States
FDA product code HSX
Device type Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3520
Establishment Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K033363
Record published 2016-02-15
Record revised 2023-09-07 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for ZUK
Catalogue number Size Status
00584205214 In distribution
00584200401 In distribution
00584201102 In distribution
00584205210 In distribution
00584209209 In distribution
00584202108 In distribution
00584202510 In distribution
00584209609 In distribution
00584209109 In distribution
00584204214 In distribution
00584205108 In distribution
00584208108 In distribution
00584207214 In distribution
00584201302 In distribution
00584202110 In distribution
00584202109 In distribution
00584209208 In distribution
00584206212 In distribution
00584202111 In distribution
00584202311 In distribution
00584202609 In distribution
00584209114 In distribution
00584206208 In distribution
00584200602 In distribution
00584209510 In distribution
00584208112 In distribution
00584209214 In distribution
00584205110 In distribution
00584202308 In distribution
00584209514 In distribution
00584203210 In distribution
E0015411-2 In distribution
00584202310 In distribution
00584200302 In distribution
00584207112 In distribution
E0015411-1 In distribution
00584201701 In distribution
E0015899-5 In distribution
00584202211 In distribution
00584202410 In distribution
00584209412 In distribution
00584209111 In distribution
00584209211 In distribution
00584208210 In distribution
E0015411-8 In distribution
E0015411-5 In distribution
00584200101 In distribution
E0015899-8 In distribution
E0015899-7 In distribution
00584200201 In distribution
00584209610 In distribution
00584201702 In distribution
00584202612 In distribution
00584200301 In distribution
00584200502 In distribution
00584202112 In distribution
00584202408 In distribution
00584207208 In distribution
00584209409 In distribution
00584208212 In distribution
00584202309 In distribution
00584209212 In distribution
00584204212 In distribution
00584201402 In distribution
00584209611 In distribution
00584202312 In distribution
00584202212 In distribution
00584201601 In distribution
00584201401 In distribution
00584202611 In distribution
00584202114 In distribution
00584203214 In distribution
00584202414 In distribution
00584207210 In distribution
00584203212 In distribution
00584209509 In distribution
00584209612 In distribution
00584203112 In distribution
00584205208 In distribution
00584209309 In distribution
00584204114 In distribution
00584201202 In distribution
00584204208 In distribution
00584200202 In distribution
00584209311 In distribution
00584205212 In distribution
00584203108 In distribution
00584202214 In distribution
00584207114 In distribution
00584204110 In distribution
00584209210 In distribution
00584202511 In distribution
00584202610 In distribution
00584203114 In distribution
E0015411-6 In distribution
00584202411 In distribution
00584208214 In distribution
00584203208 In distribution
00584209314 In distribution
00584209310 In distribution
00584203110 In distribution
00584209511 In distribution
00584209508 In distribution
00584208110 In distribution
XK000724-1 In distribution
00584201501 In distribution
00584206114 In distribution
00584205112 In distribution
E0015411-7 In distribution
E0015899-4 In distribution
00584209312 In distribution
00584209408 In distribution
00584202608 In distribution
XK000724-2 In distribution
00584202209 In distribution
00584202210 In distribution
00584208114 In distribution
00584206112 In distribution
00584206214 In distribution
00584204112 In distribution
00584209112 In distribution
00584200601 In distribution
E0015899-6 In distribution
00584205114 In distribution
00584201602 In distribution
00584202412 In distribution
E0015899-3 In distribution
00584200501 In distribution
00584206210 In distribution
00584204108 In distribution
00584202614 In distribution
00584207108 In distribution
00584202208 In distribution
00584202409 In distribution
00584209512 In distribution
00584209414 In distribution
00584209308 In distribution
E0015411-3 In distribution
00584202509 In distribution
00584200102 In distribution
00584201502 In distribution
00584207212 In distribution
00584206108 In distribution
00584209608 In distribution
00584209614 In distribution
00584209108 In distribution
00584202512 In distribution
00584207110 In distribution
00584209410 In distribution
00584209110 In distribution
00584200402 In distribution
00584202514 In distribution
00584201101 In distribution
00584206110 In distribution
00584202314 In distribution
00584201301 In distribution
00584201201 In distribution
00584204210 In distribution
00584209411 In distribution
00584208208 In distribution
00584202508 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Journey Smith & Nephew, Inc. 517
Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer Ortho Development Corp. 303
BKS® Uni Ortho Development Corp. 240
LinkSymphoKnee Waldemar Link GmbH & Co. KG 210
Moto Partial Knee System Medacta International SA 205
Arthrex® Arthrex, Inc. 199
Stride Smith & Nephew, Inc. 190
Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer Zimmer, Inc. 175
Tahoe Uni Knee System Shalby Advanced Technologies, Inc. 134
Moto Partial Knee System – Medial Medacta International SA 132
Journey II Smith & Nephew, Inc. 119
Genesis Smith & Nephew, Inc. 118

Showing 12 of 171. All products under Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K242711 2024-10-30
K211512 2021-09-16
K191211 2019-07-25
K190085 2019-02-11
K160738 2016-06-15
K152315 2015-10-28
K113038 2012-01-05
K102069 2010-10-05
K100197 2010-02-19
K081351 2008-07-24
K073175 2007-12-20
K061779 2006-08-04
K061011 2006-07-11

Recalls Naming This Product

3 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of ZUK
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Zimmer, Inc. 510(k) number 2017-11-29 Class II Packaging The LDPE bag packaging for various highly polished hip and knee implants may adhere to the highly polished surface, leaving residue or material from the LDPE bag on the implant after it is removed from the bag. 13,227 in total 2020-04-02
Zimmer, Inc. 510(k) number 2016-01-11 Class II Process control LDPE bag containing the implant adheres to the highly polished implant surface. 32537 2017-05-23
Zimmer, Inc. 510(k) number 2013-08-30 Class II Package design/selection The low density polyethylene (LDPE) bag used to package implants adheres to the highly polished surface of the devices. 32537 2014-09-25

Recalls

7 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2023-05-02 Class II Under Investigation by firm Recent complaint data indicates that the revision rate may be trending higher than corresponding similar devices in global joint replacement registries. The data identifies a potential signal that the performance is an outlier versus the st 1596 units
2023-05-02 Class II Under Investigation by firm Recent complaint data indicates that the revision rate may be trending higher than corresponding similar devices in global joint replacement registries. The data identifies a potential signal that the performance is an outlier versus the st 7531 units
2023-05-02 Class II Under Investigation by firm Recent complaint data indicates that the revision rate may be trending higher than corresponding similar
devices in global joint replacement registries. The data identifies a potential signal that the performance is an outlier versus the st
1994 units
2023-05-02 Class II Under Investigation by firm Recent complaint data indicates that the revision rate may be trending higher than corresponding similar devices in global joint replacement registries. The data identifies a potential signal that the performance is an outlier versus the st 2146 units
2023-03-27 Class II Under Investigation by firm A mispack occurred during the manufacturing process, resulting in the box incorrectly containing JOURNEY II UNI Tibia Insert Medical Size 1-2 12MM instead of the JOURNEY II UNI Tibia Insert Medial Size 7-8 8MM. 12 units
2020-01-28 Class II Process design The spike rail was manufactured with an oversized thru-hole which could potentially cause the dowel pin to fall out and the device to disassemble. 195 units 2023-12-11
2020-01-28 Class II Process design The spike rail was manufactured with an oversized thru-hole which could potentially cause the dowel pin to fall out and the device to disassemble. 200 units 2023-12-11
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 58 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 859 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 904 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 941 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 1421 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 353 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 1150 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 71 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 1004 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 704 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 56 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 628 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 849 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 817 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 60 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 57 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 960 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 838 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 379 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 863 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 895 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 734 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 89 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 1064 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 813 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 721 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 97 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 1283 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 69 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 952 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 713 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 1324 units 2011-03-25
2009-01-23 Not classified Device Design The firm has received complaints of the base plates breaking in situ. If a breakage occurs, the broken baseplate must be revised and/or changed. If left unrevised a broken base could lead to instability and premature wear of the construct. 1015 units 2011-03-25

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer