Ankle Suture Button
Ankle Suture Button for Use Within Plate Slot
9manufacturers in China registered for this device type
2catalogue numbers in this listing
Who Else Makes It
Concentrated in Jiangsu (4), Shanghai (3), Zhejiang (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
| Suzhou Endophix Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 17 |
Record
| Listed by | Tornier Inc., United States |
|---|---|
| FDA product code | HTN |
| Device type | Washer, Bolt Nut |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3030 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2015-10-16 |
| Record revised | 2025-11-20 (version 8) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Distribution end date | 2022-11-02 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| SYN-001-02 | Withdrawn | |
| SYN-001-01 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Washer, Bolt Nut | Zimmer, Inc. | 308 |
| MaxTorque™ | Tornier Inc. | 171 |
| Arthrex® | Arthrex, Inc. | 154 |
| Kyocera Medical Technologies, Inc. | Kyocera Medical Technologies, Inc. | 92 |
| Washer, Bolt Nut | Synthes Gmbh | 88 |
| A.l.p.s.® | Biomet Orthopedics | 67 |
| Variax | Stryker GmbH | 59 |
| Conmed | ConMed Corporation | 38 |
| Neoortho | Neoortho Produtos Ortopédicos S/A | 32 |
| Aptus | Medartis Inc. | 31 |
| AC Device | Lockdown Medical Limited | 31 |
| Evos | Smith & Nephew, Inc. | 28 |
Showing 12 of 304. All products under Washer, Bolt Nut