AOS Cannulated Cancellous Screw, 36mm Thread 7.0mm X 55mm
22 catalogue numbers from 8041-055, listed by Advanced Orthopaedic Solutions, Inc., United States, under Washer, Bolt Nut. 9 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (4), Shanghai (3), Zhejiang (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
| Suzhou Endophix Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 17 |
Record
| Listed by | Advanced Orthopaedic Solutions, Inc., United States |
|---|---|
| FDA product code | HTN |
| Device type | Washer, Bolt Nut |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3030 |
| Record published | 2015-11-02 |
| Record revised | 2025-12-31 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Distribution end date | 2025-12-01 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 8041-055 | Withdrawn | |
| 8041-130 | Withdrawn | |
| 8041-095 | Withdrawn | |
| 8041-085 | Withdrawn | |
| 8041-140 | Withdrawn | |
| 8041-150 | Withdrawn | |
| 8041-050 | Withdrawn | |
| 8041-070 | Withdrawn | |
| 8041-120 | Withdrawn | |
| 8041-100 | Withdrawn | |
| 8041-105 | Withdrawn | |
| 8041-060 | Withdrawn | |
| 8041-075 | Withdrawn | |
| 8041-135 | Withdrawn | |
| 8041-145 | Withdrawn | |
| 8041-125 | Withdrawn | |
| 8041-115 | Withdrawn | |
| 8041-090 | Withdrawn | |
| 8041-065 | Withdrawn | |
| 8041-045 | Withdrawn | |
| 8041-110 | Withdrawn | |
| 8041-080 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Washer, Bolt Nut | Zimmer, Inc. | 308 |
| MaxTorque™ | Tornier Inc. | 171 |
| Arthrex® | Arthrex, Inc. | 154 |
| Kyocera Medical Technologies, Inc. | Kyocera Medical Technologies, Inc. | 92 |
| Washer, Bolt Nut | Synthes Gmbh | 88 |
| A.l.p.s.® | Biomet Orthopedics | 67 |
| Variax | Stryker GmbH | 59 |
| Conmed | ConMed Corporation | 38 |
| Neoortho | Neoortho Produtos Ortopédicos S/A | 32 |
| Aptus | Medartis Inc. | 31 |
| AC Device | Lockdown Medical Limited | 31 |
| Evos | Smith & Nephew, Inc. | 28 |
Showing 12 of 304. All products under Washer, Bolt Nut
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.