RipCord
RipCord Syndesmosis Button Kit
9manufacturers in China registered for this device type
3catalogue numbers in this listing
2510(k) clearances naming this product code
1recall
Who Else Makes It
Concentrated in Jiangsu (4), Shanghai (3), Zhejiang (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
| Suzhou Endophix Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 17 |
Record
| Listed by | Trimed, Inc., United States |
|---|---|
| FDA product code | HTN |
| Device type | Washer, Bolt Nut |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3030 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K251134 |
| Record published | 2022-06-08 |
| Record revised | 2024-08-15 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Ethylene Oxide |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date, manufacturing date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| STA001 | In distribution | |
| STA001K | In distribution | |
| STA002 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Washer, Bolt Nut | Zimmer, Inc. | 308 |
| MaxTorque™ | Tornier Inc. | 171 |
| Arthrex® | Arthrex, Inc. | 154 |
| Kyocera Medical Technologies, Inc. | Kyocera Medical Technologies, Inc. | 92 |
| Washer, Bolt Nut | Synthes Gmbh | 88 |
| A.l.p.s.® | Biomet Orthopedics | 67 |
| Variax | Stryker GmbH | 59 |
| Conmed | ConMed Corporation | 38 |
| Neoortho | Neoortho Produtos Ortopédicos S/A | 32 |
| Aptus | Medartis Inc. | 31 |
| AC Device | Lockdown Medical Limited | 31 |
| Evos | Smith & Nephew, Inc. | 28 |
Showing 12 of 304. All products under Washer, Bolt Nut
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K251134 | 2025-07-11 |
| K220650 | 2022-06-01 |
Recalls Naming This Product
1 recall names this product by its own identifier, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Trimed, Inc. | UDI-DI | 2022-12-22 | Class II | Under Investigation by firm | Overly aggressive tension on the pull suture, while passing the medial button through a bone/soft tissue tunnel across the fibula and tibia, can exceed its strength causing it to break. | 76 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.