Rigidfix
RIGIDFIX FEMORAL ST CROSS PIN KIT (2) each ST Cross Pins, 3.3mm x 42mm Poly Lactic Acid (PLA), (2) each Sleeve Assemblies, and (1) each Interlocking Trocar
Who Else Makes It
Concentrated in Jiangsu (5), Shanghai (3), Zhejiang (2). 7 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
| Kingj Medical Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 7 |
| Aplus (Guangzhou) Medical Technology Company | Guangzhou | Guangdong | Contract manufacturer | 6 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
Record
| Listed by | Medos International Sàrl, Switzerland |
|---|---|
| FDA product code | HTY |
| Device type | Pin, Fixation, Smooth |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3040 |
| 510(k) | K974341 |
| Record published | 2015-09-01 |
| Record revised | 2025-04-11 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Handling environment temperature up to 26 °C; Handling environment temperature up to 80 °F; Storage environment temperature up to 26 °C; Storage environment temperature up to 80 °F |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 213023 | In distribution | |
| 213022 | In distribution | |
| 210133 | In distribution | |
| 213024 | In distribution | |
| 210127 | In distribution | |
| 213037 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Rondo’ | Citieffe SRL | 265 |
| HNM Medical | HNM Stainless, LLC. | 232 |
| Kmedic | Teleflex Medical LLC | 227 |
| gSource | Gsource, LLC. | 221 |
| MicroAire® | Microaire Surgical Instruments LLC | 213 |
| Orthomed | Ortho-MED, Inc. | 163 |
| mahe medical GmbH | Mahe Intl., Inc. | 160 |
| Pin, Fixation, Smooth | Key Surgical, LLC | 134 |
| Pin, Fixation, Smooth | Stryker GmbH | 134 |
| Aptus | Medartis Inc. | 134 |
| Key Surgical K-Wires and Steinmann Pins | Key Surgical, LLC | 126 |
| PedFlex Flexible Nailing System | Orthopediatrics, Corp | 119 |
Showing 12 of 682. All products under Pin, Fixation, Smooth
Recalls Naming This Product
5 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| DePuy Mitek, Inc. | 510(k) number | 2023-04-13 | Class II | Use error | IFU Warning: Applying bending force and/or bending force with impaction to the BIOKNOTLESS Anchor Inserter may cause a fragment of the inserter tip to break off during use and be retained in the patient. broken BIOKNOTLESS Anchor inserter t | 805 units |
| DePuy Mitek, Inc. | 510(k) number | 2023-04-13 | Class II | Use error | IFU Warning: Applying bending force and/or bending force with impaction to the BIOKNOTLESS Anchor Inserter may cause a fragment of the inserter tip to break off during use and be retained in the patient. broken BIOKNOTLESS Anchor inserter t | 540 units |
| DePuy Mitek, Inc. | 510(k) number | 2023-04-13 | Class II | Use error | IFU Warning: Applying bending force and/or bending force with impaction to the BIOKNOTLESS Anchor Inserter may cause a fragment of the inserter tip to break off during use and be retained in the patient. broken BIOKNOTLESS Anchor inserter t | 2372 units |
| DePuy Mitek, Inc. | 510(k) number | 2023-04-13 | Class II | Use error | IFU Warning: Applying bending force and/or bending force with impaction to the BIOKNOTLESS Anchor Inserter may cause a fragment of the inserter tip to break off during use and be retained in the patient. broken BIOKNOTLESS Anchor inserter t | 3328 units |
| DePuy Mitek, Inc. | 510(k) number | 2023-04-13 | Class II | Use error | IFU Warning: Applying bending force and/or bending force with impaction to the BIOKNOTLESS Anchor Inserter may cause a fragment of the inserter tip to break off during use and be retained in the patient. broken BIOKNOTLESS Anchor inserter t | 1125 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.