Acumed
2.3mm X 20mm Non-Toggling Cortical Screw
Who Else Makes It
Concentrated in Jiangsu (15), Shanghai (5), Zhejiang (3). 19 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Sanbor Medical Xiamen, Inc. | Xiamen | Fujian | Contract manufacturer | 16 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
Showing 12 of 31. All 31 manufacturers in China registered for Screw, Fixation, Bone
Record
| Listed by | Acumed LLC, United States |
|---|---|
| FDA product code | HWC |
| Device type | Screw, Fixation, Bone |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3040 |
| Establishment | Specification developer, Repacker / relabeller, Manufacturer |
| 510(k) | K141383 |
| Record published | 2023-07-29 |
| Record revised | 2025-03-27 (version 8) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, manufacturing date |
| Storage | Storage environment temperature up to 120 °F |
| Sizes | Length 10 to 16 mm |
| Distribution end date | 2022-10-05 |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 3050-20028 | In distribution | |
| HCA-5140 | In distribution | |
| 3012-23005-S | In distribution | |
| 30-0544 | In distribution | |
| 3005-65090 | In distribution | |
| 30-0319-S | In distribution | |
| 30-0899 | In distribution | |
| FA-CO3560-S | In distribution | |
| 3005-50068 | In distribution | |
| CO-3180-S | In distribution | |
| 30-0259 | In distribution | |
| 30-0303-S | In distribution | |
| 80-0655 | In distribution | |
| 3006-40028-S | In distribution | |
| AT-1200 | In distribution | |
| 3007-50024 | In distribution | |
| COL-2360 | In distribution | |
| 3006-40030-S | In distribution | |
| FA-0160 | In distribution | |
| 3005-73070 | In distribution | |
| 3005-65060 | In distribution | |
| 80-1628 | In distribution | |
| 30-0508 | In distribution | |
| 3006-73055 | In distribution | |
| CA-4260 | In distribution | |
| 27-0220 | In distribution | |
| 3005-40034 | In distribution | |
| AM-0040 | In distribution | |
| 3013-27026 | In distribution | |
| AP-67120-S | In distribution | |
| 3011-43052 | In distribution | |
| 3005-45076 | In distribution | |
| 3007-35022 | In distribution | |
| CO-3280-S | In distribution | |
| 30-0261-S | In distribution | |
| 30-0306 | In distribution | |
| 3007-50032 | In distribution | |
| 30-0228 | In distribution | |
| 3015-40045-S | In distribution | |
| 3051-25026-S | In distribution | |
| 20-0455-S | In distribution | |
| CO-N2320 | In distribution | |
| FA-CO2750-S | In distribution | |
| 3013-35034 | In distribution | |
| 3005-50030 | In distribution | |
| 3006-30034 | In distribution | |
| 3007-73050 | In distribution | |
| 3006-73120-S | In distribution | |
| 20-0152 | In distribution | |
| AT2-C13-S | In distribution | |
| FA-CO2750 | In distribution | |
| HCA-L5345-S | In distribution | |
| COL-3140-S | In distribution | |
| LAG-4350-S | In distribution | |
| 3004-23022-S | In distribution | |
| 3005-30048 | In distribution | |
| 3004-23009 | In distribution | |
| 3004-23006 | In distribution | |
| FA-CO2755 | In distribution | |
| 30-0031 | In distribution | |
| 30-0292 | In distribution | |
| 3018-47050-S | In distribution | |
| 3053-40022-S | In distribution | |
| 3007-65120 | In distribution | |
| 30-0645 | In distribution | |
| 30-0901-S | In distribution | |
| 3006-73130 | In distribution | |
| CA-4350 | In distribution | |
| 20-0556-S | In distribution | |
| 30-0326-S | In distribution | |
| 3018-47032 | In distribution | |
| AI-0012-S | In distribution | |
| 3052-35060 | In distribution | |
| 30170008-S | In distribution | |
| 3006-73080 | In distribution | |
| 3011-43014 | In distribution | |
| 3013-27046 | In distribution | |
| 3005-73095 | In distribution | |
| 30-0878 | In distribution | |
| HCO3250-S | In distribution | |
| 30-2842 | In distribution | |
| HCA-5120 | In distribution | |
| 3053-40056 | In distribution | |
| 30-0353-S | In distribution | |
| 3007-35044 | In distribution | |
| 3007-45064 | In distribution | |
| CO-3260-S | In distribution | |
| 3053-40056-S | In distribution | |
| 3007-50026 | In distribution | |
| CO-N2346 | In distribution | |
| AI-0020-S | In distribution | |
| FA-CO2760-S | In distribution | |
| 20-0163 | In distribution | |
| 3017-10007-S | In distribution | |
| CO-3060-S | In distribution | |
| 30-0906-S | In distribution | |
| ATF-140 | In distribution | |
| FA-0140-S | In distribution | |
| 3007-45044 | In distribution | |
| 30-0293 | In distribution | |
| CO-3500 | In distribution | |
| HCA-5150 | In distribution | |
| 3007-65120-S | In distribution | |
| COL-3140 | In distribution | |
| 3005-65110-S | In distribution | |
| 30-0365-S | In distribution | |
| 20-0465-S | In distribution | |
| 3004-15010-S | In distribution | |
| 3051-25048-S | In distribution | |
| 30-0327-S | In distribution | |
| 3005-40020 | In distribution | |
| 30-0886-S | In distribution | |
| CA-4225-S | In distribution | |
| 30170011-S | In distribution | |
| 3040-23010-S | In distribution | |
| 30-0295-S | In distribution | |
| CO-3200-S | In distribution | |
| 3006-65140 | In distribution | |
| 3040-23012-S | In distribution | |
| AI-0026-S | In distribution | |
| AT2-S26-S | In distribution | |
| CO-T2344 | In distribution | |
| 3006-73045-S | In distribution | |
| 30100059 | In distribution | |
| 3004-15006-S | In distribution | |
| 3012-15009 | In distribution | |
| CO-T2308 | In distribution | |
| FA-4036-S | In distribution | |
| 3012-15013-S | In distribution | |
| 30-0514 | In distribution | |
| 30-2330-S | In distribution | |
| CO-N2324 | In distribution | |
| 3006-40024-S | In distribution | |
| 3005-65150-S | In distribution | |
| 3004-15010 | In distribution | |
| 20-0447 | In distribution | |
| 30-0356-S | In distribution | |
| 30-0239 | In distribution | |
| 30-0349-S | In distribution | |
| COL-2180 | In distribution | |
| 3005-40036-S | In distribution | |
| FA-CO2736 | In distribution | |
| CA-4220-S | In distribution | |
| 20-0572 | In distribution | |
| 30-0883-S | In distribution | |
| FA-CO2718 | In distribution | |
| COL-3500-S | In distribution | |
| 3004-15007 | In distribution | |
| 20-0451 | In distribution | |
| 30-0264 | In distribution | |
| CO-T2338 | In distribution | |
| 30-0606 | In distribution | |
| 30-0030-S | In distribution | |
| 3053-40020-S | In distribution | |
| 3006-40034 | In distribution | |
| CO-T2330-S | In distribution | |
| 3015-40026 | In distribution | |
| 20-0189-S | In distribution | |
| 3005-30050 | In distribution | |
| CO-T2328 | In distribution | |
| 3005-30044 | In distribution | |
| 3005-40044 | In distribution | |
| 30-0898-S | In distribution | |
| 3011-43042-S | In distribution | |
| 80-0614 | In distribution | |
| 3006-40038-S | In distribution | |
| COL-2280-S | In distribution | |
| 30-0131 | In distribution | |
| 30-0310 | In distribution | |
| CO-F2722-S | In distribution | |
| 3016-40018 | In distribution | |
| AT2-C28 | In distribution | |
| 30-0162 | In distribution | |
| 20-0168-S | In distribution | |
| 20-0463 | In distribution | |
| 3006-73090 | In distribution | |
| 20-0198 | In distribution | |
| 3006-73125 | In distribution | |
| CO-F2710-S | In distribution | |
| 3006-73045 | In distribution | |
| 30100009 | In distribution | |
| 3052-35050 | In distribution | |
| HCA-L5320-S | In distribution | |
| 30-0446-S | In distribution | |
| CO-2722 | In distribution | |
| 3011-43012-S | In distribution | |
| 3052-35028 | In distribution | |
| FA-CO2738 | In distribution | |
| 3005-40040-S | In distribution | |
| ATF-370-S | In distribution | |
| FA-CO3530 | In distribution | |
| HCA5475-S | In distribution | |
| 30-0315 | In distribution | |
| 3041-23013 | In distribution | |
| 3005-65075-S | In distribution | |
| 3005-73105 | In distribution | |
| 40-0146-S | In distribution | |
| 30-2338-S | In distribution | |
| CO-2720-S | In distribution | |
| 30-0363 | In distribution | |
| AT2-C24-S | In distribution | |
| CO-2720 | In distribution | |
| HCA-L5352-S | In distribution | |
| RBP1202 | In distribution | |
| FA-CO2726-S | In distribution | |
| 3051-25024 | In distribution | |
| CA-4160-S | In distribution | |
| 3006-40058-S | In distribution | |
| 3018-47034-S | In distribution | |
| 30-0324 | In distribution | |
| 3005-73075 | In distribution | |
| 3018-47012-S | In distribution | |
| MS-4500 | In distribution | |
| 30-0264-S | In distribution | |
| 3003-43052-S | In distribution | |
| CO-27275-S | In distribution | |
| LAG-5054-S | In distribution | |
| AP-0040 | In distribution | |
| CO-T2312 | In distribution | |
| LAG-4300-S | In distribution | |
| 3005-73035 | In distribution | |
| 3011-43058-S | In distribution | |
| 3005-73035-S | In distribution | |
| HCA5375-S | In distribution | |
| 80-0054 | In distribution | |
| CO-F2110-S | In distribution | |
| CO-S2110 | In distribution | |
| 30-0309-S | In distribution | |
| EXINN921525 | In distribution | |
| 3065-20028 | In distribution | |
| 3006-73110 | In distribution | |
| CO-27375 | In distribution | |
| 30-0231-S | In distribution | |
| CA-4180-S | In distribution | |
| 27-0120 | In distribution | |
| 3004-15016 | In distribution | |
| 3040-23012 | In distribution | |
| FA-CO2720-S | In distribution | |
| 3005-65075 | In distribution | |
| CO-3275 | In distribution | |
| 30-0304-S | In distribution | |
| FA-4030-S | In distribution | |
| FA-0260-S | In distribution | |
| FA-CO3518 | In distribution | |
| RBP1212 | In distribution | |
| 20-0462 | In distribution | |
| COL-2550 | In distribution | |
| 46-0005-S | In distribution | |
| ATM-160 | In distribution | |
| FA-0200 | In distribution |
Showing 250 of 300 catalogue numbers.
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Screw, Fixation, Bone | Synthes Gmbh | 3,975 |
| Aptus | Medartis Inc. | 3,623 |
| Arthrex® | Arthrex, Inc. | 2,781 |
| OsteoMed | Osteomed | 2,764 |
| Screw, Fixation, Bone | AAP Implantate AG | 2,176 |
| Screw, Fixation, Bone | Zimmer, Inc. | 1,993 |
| Arix System Bone Screw | Jeil Medical Corporation | 1,875 |
| Cannulated Screw System + | Tyber Medical | 1,814 |
| Cannulated Compression Headless Screw | Tyber Medical | 1,621 |
| Microware Bone Plates and Bone Screws | Microware Precision Co., Ltd. | 1,601 |
| Anthem | Globus Medical, Inc. | 1,538 |
| Volt | Synthes Gmbh | 1,444 |
Showing 12 of 5,775. All products under Screw, Fixation, Bone
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K230744 | 2023-06-09 |
| K221333 | 2022-12-29 |
| K123890 | 2013-03-18 |
| K111608 | 2011-08-29 |
| K033639 | 2004-01-15 |
Recalls Naming This Product
6 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Acumed LLC | UDI-DI | 2026-05-28 | Class II | Device Design | Due to manufacturing error, hexalobe screws used with wrist fixation system may break during use. | 5,272 units | |
| Acumed LLC | 510(k) number | 2022-03-09 | Class II | Device Design | Cannulated Screws 4.0mm x 10mm and 4.0mm x 12mm may not have sufficient axial pullout strength for the indicated use. Remote possibility of resulting in a mal or nonunion of the bone fragments, iatrogenic fracture, joint impingement or dam | 537 units | |
| Acumed LLC | 510(k) number | 2022-03-09 | Class II | Device Design | Cannulated Screws 4.0mm x 10mm and 4.0mm x 12mm may not have sufficient axial pullout strength for the indicated use. Remote possibility of resulting in a mal or nonunion of the bone fragments, iatrogenic fracture, joint impingement or dam | 506 unit | |
| Acumed LLC | 510(k) number | 2009-05-19 | Not classified | Employee error | Mix-up of parts – Product labeled cortical bone screw actually contains Acutract fixation screw | 83 | 2010-05-17 |
| Acumed LLC | 510(k) number | 2007-07-09 | Not classified | Packaging process control | Product mislabeled. The inner sticky labels for the patient identified the product incorrectly as a Cortical screw (non-locking). The product package was labeled correctly. | 400 screws | 2010-02-03 |
| Acumed LLC | 510(k) number | 2005-12-27 | Not classified | Process change control | Package of 3.5mm X 32.5mm cortical screw may contain 3.5mm X 22.5mm cortical screw. | 112 pieces | 2010-02-03 |
Recalls
4 of these are Class II. Class II means a temporary or reversible health consequence. 4 are recorded with the root cause “No Marketing Application”: the device was distributed without the premarket submission its class requires, a compliance finding rather than a defect. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2022-11-29 | Class II | No Marketing Application | Distribution without Pre-Market Clearance | Total 306,934 units (Acutrak 239,611 units and Mini Acutrak | |
| 2022-11-29 | Class II | No Marketing Application | Distribution without Pre-Market Clearance | 80,805 units | |
| 2022-11-29 | Class II | No Marketing Application | Distribution without Pre-Market Clearance | 7,498 units | |
| 2022-11-29 | Class II | No Marketing Application | Distribution without Pre-Market Clearance | 1,681,860 units (Acutrak 2 286,026; Micro Acutrak 2 524,566; | |
| 2009-08-21 | Not classified | Pending | Labeling may contain 2 lot numbers and 2 model numbers. It was observed that the box top label (30170060-S, W67391) does not match the two side labels (3010320-S, W67385). The part and patient labeling inside the box match the side labels | 125 | 2010-11-06 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 3 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 10 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 10 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 10 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 3 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 31 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 3 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 3 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 10 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 20 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 20 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 20 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 10 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 20 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 3 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 10 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 3 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 3 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 7 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 3 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 20 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 3 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 10 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 30 pcs | 2010-02-03 |
| 2008-02-14 | Not classified | Packaging process control | Product sterility may be compromised. | 3 pcs | 2010-02-03 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability.
Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.