Instrument

Specialty Exeter Flexible Trial Plug

Registry build 21.09.26
5manufacturers in China registered for this device type
7catalogue numbers in this listing
6recalls on this code

Who Else Makes It

Concentrated in Jiangsu (3), Shanghai (1), Zhejiang (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JDG
Manufacturer City Province Registered as Device types
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Suzhou Ahno Medical Devices Co., Ltd. Suzhou Jiangsu Contract manufacturer 17
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Record

Regulatory record for Instrument
Listed by Howmedica Osteonics Corp, United States
FDA product code JDG
Device type Prosthesis, Hip, Femoral Component, Cemented, Metal
Device class Class 2
Regulation 21 CFR 888.3360
Establishment Contract manufacturer, Contract steriliser, Specification developer, Manufacturer
Record published 2018-05-03
Record revised 2021-11-03 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number
Sizes Length 125 to 150 mm
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Instrument
Catalogue number Size Status
0585-9-352 Offset: 37.5 Millimeter In distribution
I-H19660114 Diameter: 14.0 Millimeter In distribution
I-H19660116 Diameter: 16.0 Millimeter In distribution
0585-9-443 Offset: 44.0 Millimeter In distribution
0585-3-371 Size: 1 In distribution
I-H19660108 Diameter: 8.0 Millimeter In distribution
0585-9-562 Offset: 56.0 Millimeter In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
R3 Smith & Nephew, Inc. 554
Emperion Smith & Nephew, Inc. 262
Reflection Smith & Nephew, Inc. 253
Spii Model Lubinus Waldemar Link GmbH & Co. KG 174
Polar Smith & Nephew, Inc. 132
Anthology Smith & Nephew, Inc. 129
Echelon Smith & Nephew, Inc. 122
Synergy Smith & Nephew, Inc. 102
Prosthesis, Hip, Femoral Component, Cemented, Metal Smith & Nephew, Inc. 93
Trigen Smith & Nephew, Inc. 66
Prosthesis Head B Waldemar Link GmbH & Co. KG 62
Corin Taper-Fit Total Hip System Corin Limited 55

Showing 12 of 71. All products under Prosthesis, Hip, Femoral Component, Cemented, Metal

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2021-12-30 Class II Labeling mix-ups There is a potential label mix between certain lots of Exeter V40 Cemented Hip (125mm) Stem and Exeter V40 Cemented Hip (150mm) Stem. 59 devices 2024-03-14
2021-12-30 Class II Labeling mix-ups There is a potential label mix between certain lots of Exeter V40 Cemented Hip (125mm) Stem and Exeter V40 Cemented Hip (150mm) Stem. 58 devices 2024-03-14
2021-10-15 Class II Under Investigation by firm There is a potential for the outer white Tyvek lid to debond from the sealed package.
2021-10-15 Class II Under Investigation by firm XXX
2009-09-04 Not classified Process control Packaging mix up between the Taper V40 Femoral Head and the LFIT V40 Femoral Head. 7 units 2013-06-26
2009-09-04 Not classified Process control Packaging mix up between the Taper V40 Femoral Head and the LFIT V40 Femoral Head. 10 units 2013-06-26

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer