Integral Centralizer HIP System

4 catalogue numbers from 11-162717, listed by Biomet Orthopedics, United States, under Prosthesis, Hip, Femoral Component, Cemented, Metal. 5 manufacturers in China are registered for this product code.

Registry build 21.09.26
5manufacturers in China registered for this device type
4catalogue numbers in this listing

Who Else Makes It

Concentrated in Jiangsu (3), Shanghai (1), Zhejiang (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JDG
Manufacturer City Province Registered as Device types
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Suzhou Ahno Medical Devices Co., Ltd. Suzhou Jiangsu Contract manufacturer 17
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Record

Regulatory record for Integral Centralizer HIP System
Listed by Biomet Orthopedics, United States
FDA product code JDG
Device type Prosthesis, Hip, Femoral Component, Cemented, Metal
Device class Class 2
Regulation 21 CFR 888.3360
510(k) K942479
Record published 2015-10-24
Record revised 2025-05-30 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for Integral Centralizer HIP System
Catalogue number Size Status
11-162717 17 SIZE 165 MM TYPE1 TAPER In distribution
11-162715 15 SIZE 155 MM TYPE1 TAPER In distribution
11-162709 9 SIZE 125 MM TYPE1 TAPER In distribution
12-162617 17 SIZE 165 MM TYPE1 TAPER In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
R3 Smith & Nephew, Inc. 554
Emperion Smith & Nephew, Inc. 262
Reflection Smith & Nephew, Inc. 253
Spii Model Lubinus Waldemar Link GmbH & Co. KG 174
Polar Smith & Nephew, Inc. 132
Anthology Smith & Nephew, Inc. 129
Echelon Smith & Nephew, Inc. 122
Synergy Smith & Nephew, Inc. 102
Prosthesis, Hip, Femoral Component, Cemented, Metal Smith & Nephew, Inc. 93
Trigen Smith & Nephew, Inc. 66
Prosthesis Head B Waldemar Link GmbH & Co. KG 62
Corin Taper-Fit Total Hip System Corin Limited 55

Showing 12 of 71. All products under Prosthesis, Hip, Femoral Component, Cemented, Metal

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Integral Centralizer HIP System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Biomet, Inc. 510(k) number 2015-11-17 Class II Labeling Change Control PMMA is listed as a material on the label but the product does not contain PMMA. 21 2016-07-05

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer