Prosthesis Head A

Modular Prosthesis Head,Ceramic - Biolox forte

Registry build 21.09.26
5manufacturers in China registered for this device type
2catalogue numbers in this listing
6recalls on this code

Who Else Makes It

Concentrated in Jiangsu (3), Shanghai (1), Zhejiang (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JDG
Manufacturer City Province Registered as Device types
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Suzhou Ahno Medical Devices Co., Ltd. Suzhou Jiangsu Contract manufacturer 17
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Record

Regulatory record for Prosthesis Head A
Listed by Waldemar Link GmbH & Co. KG, Germany
FDA product code JDG
Device type Prosthesis, Hip, Femoral Component, Cemented, Metal
Device class Class 2
Regulation 21 CFR 888.3360
Establishment Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K953653
Record published 2015-11-01
Record revised 2020-09-09 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries expiry date, serial number
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Prosthesis Head A
Catalogue number Size Status
128-936/01 In distribution
128-936/02 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
R3 Smith & Nephew, Inc. 554
Emperion Smith & Nephew, Inc. 262
Reflection Smith & Nephew, Inc. 253
Spii Model Lubinus Waldemar Link GmbH & Co. KG 174
Polar Smith & Nephew, Inc. 132
Anthology Smith & Nephew, Inc. 129
Echelon Smith & Nephew, Inc. 122
Synergy Smith & Nephew, Inc. 102
Prosthesis, Hip, Femoral Component, Cemented, Metal Smith & Nephew, Inc. 93
Trigen Smith & Nephew, Inc. 66
Prosthesis Head B Waldemar Link GmbH & Co. KG 62
Corin Taper-Fit Total Hip System Corin Limited 55

Showing 12 of 71. All products under Prosthesis, Hip, Femoral Component, Cemented, Metal

Recalls Naming This Product

5 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Prosthesis Head A
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Waldemar Link GmbH & Co. KG 510(k) number 2025-07-15 Class II Under Investigation by firm Inconsistent size terminology and color coding used on labeling 46 units
Waldemar Link GmbH & Co. KG 510(k) number 2024-02-06 Class II Under Investigation by firm Due to two complaints, has come to our attention that additional guidance is required on the correct interpretation of the carton label Size and Type columns to avoid misinterpretation during surgery. 382 units
Waldemar Link GmbH & Co. KG 510(k) number 2024-02-06 Class II Under Investigation by firm Due to two complaints, has come to our attention that additional guidance is required on the correct interpretation of the carton label Size and Type columns to avoid misinterpretation during surgery. 34 units
Waldemar Link GmbH & Co. KG 510(k) number 2024-02-06 Class II Under Investigation by firm Due to two complaints, has come to our attention that additional guidance is required on the correct interpretation of the carton label Size and Type columns to avoid misinterpretation during surgery. 153 Units
Waldemar Link GmbH & Co. KG 510(k) number 2024-02-06 Class II Under Investigation by firm Due to two complaints, has come to our attention that additional guidance is required on the correct interpretation of the carton label Size and Type columns to avoid misinterpretation during surgery. 0 units

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2025-07-15 Class II Under Investigation by firm Inconsistent size terminology and color coding used on labeling 17 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer