Prosthesis Head Large
Prosthesis Head,
Who Else Makes It
Concentrated in Jiangsu (3), Shanghai (1), Zhejiang (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Record
| Listed by | Waldemar Link GmbH & Co. KG, Germany |
|---|---|
| FDA product code | JDG |
| Device type | Prosthesis, Hip, Femoral Component, Cemented, Metal |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3360 |
| Establishment | Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K953653 |
| Record published | 2015-11-01 |
| Record revised | 2020-04-06 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | expiry date, serial number |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 99-0711/58 | In distribution | |
| 99-0711/50 | In distribution | |
| 99-0710/54 | In distribution | |
| 99-0710/50 | In distribution | |
| 99-0711/54 | In distribution | |
| 99-0710/58 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| R3 | Smith & Nephew, Inc. | 554 |
| Emperion | Smith & Nephew, Inc. | 262 |
| Reflection | Smith & Nephew, Inc. | 253 |
| Spii Model Lubinus | Waldemar Link GmbH & Co. KG | 174 |
| Polar | Smith & Nephew, Inc. | 132 |
| Anthology | Smith & Nephew, Inc. | 129 |
| Echelon | Smith & Nephew, Inc. | 122 |
| Synergy | Smith & Nephew, Inc. | 102 |
| Prosthesis, Hip, Femoral Component, Cemented, Metal | Smith & Nephew, Inc. | 93 |
| Trigen | Smith & Nephew, Inc. | 66 |
| Prosthesis Head B | Waldemar Link GmbH & Co. KG | 62 |
| Corin Taper-Fit Total Hip System | Corin Limited | 55 |
Showing 12 of 71. All products under Prosthesis, Hip, Femoral Component, Cemented, Metal
Recalls Naming This Product
5 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Waldemar Link GmbH & Co. KG | 510(k) number | 2025-07-15 | Class II | Under Investigation by firm | Inconsistent size terminology and color coding used on labeling | 46 units |
| Waldemar Link GmbH & Co. KG | 510(k) number | 2024-02-06 | Class II | Under Investigation by firm | Due to two complaints, has come to our attention that additional guidance is required on the correct interpretation of the carton label Size and Type columns to avoid misinterpretation during surgery. | 382 units |
| Waldemar Link GmbH & Co. KG | 510(k) number | 2024-02-06 | Class II | Under Investigation by firm | Due to two complaints, has come to our attention that additional guidance is required on the correct interpretation of the carton label Size and Type columns to avoid misinterpretation during surgery. | 34 units |
| Waldemar Link GmbH & Co. KG | 510(k) number | 2024-02-06 | Class II | Under Investigation by firm | Due to two complaints, has come to our attention that additional guidance is required on the correct interpretation of the carton label Size and Type columns to avoid misinterpretation during surgery. | 153 Units |
| Waldemar Link GmbH & Co. KG | 510(k) number | 2024-02-06 | Class II | Under Investigation by firm | Due to two complaints, has come to our attention that additional guidance is required on the correct interpretation of the carton label Size and Type columns to avoid misinterpretation during surgery. | 0 units |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2025-07-15 | Class II | Under Investigation by firm | Inconsistent size terminology and color coding used on labeling | 17 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.