AcuMatch

PILOT SHAFT, REAMER, CONICAL, 13mm x 165mm

Registry build 21.09.26
13manufacturers in China registered for this device type
9catalogue numbers in this listing
12510(k) clearances naming this product code
3recalls on this code

Who Else Makes It

Concentrated in Jiangsu (6), Shanghai (3), Zhejiang (2). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JDI
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Showing 12 of 13. All 13 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented

Record

Regulatory record for AcuMatch
Listed by Exactech, Inc., United States
FDA product code JDI
Device type Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
Device class Class 2
Regulation 21 CFR 888.3350
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K010120
Record published 2022-08-25
Record revised 2025-08-28 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number
Sizes Outer diameter 9 to 31 mm; length 135 to 165 mm
Distribution end date 2024-06-13

Catalogue Numbers

Catalogue numbers for AcuMatch
Catalogue number Size Status
113-05-01 SZ 1 In distribution
107-11-00 In distribution
151-05-29 Outer Diameter 29 mm Withdrawn
151-05-31 Outer Diameter 31 mm Withdrawn
151-06-09 Length 135 mm Withdrawn
151-06-13 Pilot Outer Diameter Withdrawn
151-05-25 Outer Diameter 25 mm Withdrawn
151-05-23 Outer Diameter 23 mm Withdrawn
153-01-00 12/14 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented Zimmer, Inc. 836
R3 Smith & Nephew, Inc. 497
UniSyn Hip System Shalby Advanced Technologies, Inc. 247
UniSyn® Hip System Consensus Orthopedics, Inc. 247
Reflection Smith & Nephew, Inc. 170
Instrument Howmedica Osteonics Corp 167
Echelon Smith & Nephew, Inc. 159
B-P Total HIP System Endotec, Inc. 151
ZCA® Zimmer, Inc. 149
Omnifit Howmedica Osteonics Corp 149
Ringloc HIP System Biomet Orthopedics 139
Profemur Microport Orthopedics Inc. 113

Showing 12 of 444. All products under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K051335 2005-06-21
K023646 2002-11-13
K020291 2002-02-27
K012493 2001-08-29
K011218 2001-05-16
K001335 2000-05-18
K964262 1996-12-27
K963313 1996-11-14
K961304 1996-10-01
K925201 1993-06-15
K901297 1990-05-02
K862234 1986-10-15

Recalls Naming This Product

3 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of AcuMatch
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Exactech, Inc. 510(k) number 2022-08-11 Class II Process control Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear. 132 devices
Exactech, Inc. 510(k) number 2007-11-01 Not classified Process control Mislabeled: A ten piece lot of 140-32-03, 12/14 BIOLOXforte Alumina Femoral Heads 32mm (1069020 – 1069029), from Ceramtec were incorrectly labeled as 140-28-03 12/14 BIOLOXforte Alumina Femoral Heads, 28mm 10 2012-05-06
Exactech, Inc. 510(k) number 2006-07-21 Not classified Other The packaging was mislabeled: Exterior and interior packaging on the device was labeled with catalog number 150-07-19 15mm x 200mm, however, the actual part inside the packaging was a 21mm x 200mm (catalog number 150-07-44) device. 6 2012-05-06

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2022-08-11 Class II Process control Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear. 7946 devices
2022-08-11 Class II Process control Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear. 4956 devices
2016-11-07 Class II Under Investigation by firm Products were labeled with incorrect Global Trade Item Numbers. The GTIN on the label identifies the devices as another. 79 units 2019-08-05

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer