Concentrated in Jiangsu (6), Shanghai (3), Zhejiang (2). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| b-ONE Medical (Beijing) Co., Ltd. | Beijing | Beijing | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Showing 12 of 13. All 13 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
Record
| Listed by | Exactech, Inc., United States |
|---|---|
| FDA product code | JDI |
| Device type | Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3350 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K182502 |
| Record published | 2019-03-25 |
| Record revised | 2026-02-09 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date, manufacturing date, serial number |
| Sizes | Lumen/inner diameter 22 to 40 mm; outer diameter 40 to 68 mm |
| Distribution end date | 2024-04-04 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 01-030-40-0636 | Neutral | In distribution |
| 01-030-42-0532 | Extended Coverage | In distribution |
| 01-030-42-0732 | Extended Coverage | In distribution |
| 01-030-42-0640 | Extended Coverage | In distribution |
| 01-030-01-0144 | Cluster Hole | In distribution |
| 01-030-01-0348 | Cluster Hole | In distribution |
| 01-030-40-0128 | Neutral | In distribution |
| 01-001-01-0004 | Right | In distribution |
| 01-030-40-0736 | Neutral | In distribution |
| 01-030-40-0640 | Neutral | In distribution |
| 01-030-01-0756 | Cluster Hole | In distribution |
| 01-030-42-0232 | Extended Coverage | In distribution |
| 01-030-42-0436 | Extended Coverage | In distribution |
| 01-030-40-0228 | Neutral | In distribution |
| 01-030-40-0436 | Neutral | In distribution |
| 01-030-40-0732 | Neutral | In distribution |
| 01-030-01-0862 | Cluster Hole | In distribution |
| 01-030-40-0122 | Neutral | In distribution |
| 01-030-42-0832 | Extended Coverage | In distribution |
| 01-030-42-0228 | Extended Coverage | In distribution |
| 01-030-42-0128 | Extended Coverage | In distribution |
| 01-030-01-0246 | Cluster Hole | In distribution |
| 01-030-40-0432 | Neutral | In distribution |
| 01-030-42-0632 | Extended Coverage | In distribution |
| 01-030-01-0868 | Cluster Hole | In distribution |
| 01-030-42-0636 | Extended Coverage | In distribution |
| 01-030-40-0022 | Neutral | In distribution |
| 01-030-40-0840 | Neutral | In distribution |
| 01-030-40-0740 | Neutral | In distribution |
| 01-030-40-0328 | Neutral | In distribution |
| 01-001-01-0005 | Left | In distribution |
| 01-030-01-0654 | Cluster Hole | In distribution |
| 01-030-40-0836 | Neutral | In distribution |
| 01-030-01-0142 | Outer Diameter 42 mm | In distribution |
| 01-030-40-0632 | Neutral | In distribution |
| 01-030-42-0840 | Extended Coverage | In distribution |
| 01-030-01-0760 | Cluster Hole | In distribution |
| 01-030-40-0532 | Neutral | In distribution |
| 01-030-40-0536 | Neutral | In distribution |
| 01-030-42-0836 | Extended Coverage | In distribution |
| 01-030-01-0866 | Cluster Hole | In distribution |
| 01-030-40-0832 | Neutral | In distribution |
| 01-030-01-0040 | Cluster Hole | In distribution |
| 01-030-42-0328 | Extended Coverage | In distribution |
| 01-030-01-0758 | Cluster Hole | In distribution |
| 01-030-42-0432 | Extended Coverage | In distribution |
| 01-030-42-0740 | Extended Coverage | In distribution |
| 01-030-01-0450 | Cluster Hole | In distribution |
| 01-030-40-0232 | Neutral | In distribution |
| 01-030-01-0552 | Cluster Hole | In distribution |
| 01-030-42-0332 | Extended Coverage | In distribution |
| 01-030-40-0332 | Neutral | In distribution |
| 01-030-01-0864 | Cluster Hole | In distribution |
| 01-030-42-0536 | Extended Coverage | In distribution |
| 01-030-42-0736 | Extended Coverage | In distribution |
| 01-030-40-0522 | Neutral | Withdrawn |
| 01-030-40-0628 | Neutral | Withdrawn |
| 01-030-42-0628 | Extended Coverage | Withdrawn |
| 01-030-40-0422 | Neutral | Withdrawn |
| 01-030-40-0722 | Neutral | Withdrawn |
| 01-030-40-0622 | Neutral | Withdrawn |
| 01-030-40-0822 | Neutral | Withdrawn |
| 01-030-40-0322 | Neutral | Withdrawn |
| 01-030-42-0428 | Extended Coverage | Withdrawn |
| 01-030-42-0828 | Extended Coverage | Withdrawn |
| 01-030-42-0728 | Extended Coverage | Withdrawn |
| 01-030-40-0728 | Neutral | Withdrawn |
| 01-030-40-0828 | Neutral | Withdrawn |
| 01-030-40-0528 | Neutral | Withdrawn |
| 01-030-42-0528 | Extended Coverage | Withdrawn |
| 01-030-40-0222 | Neutral | Withdrawn |
| 01-030-40-0428 | Neutral | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented | Zimmer, Inc. | 836 |
| R3 | Smith & Nephew, Inc. | 497 |
| UniSyn Hip System | Shalby Advanced Technologies, Inc. | 247 |
| UniSyn® Hip System | Consensus Orthopedics, Inc. | 247 |
| Reflection | Smith & Nephew, Inc. | 170 |
| Instrument | Howmedica Osteonics Corp | 167 |
| Echelon | Smith & Nephew, Inc. | 159 |
| B-P Total HIP System | Endotec, Inc. | 151 |
| ZCA® | Zimmer, Inc. | 149 |
| Omnifit | Howmedica Osteonics Corp | 149 |
| Ringloc HIP System | Biomet Orthopedics | 139 |
| Profemur | Microport Orthopedics Inc. | 113 |
Showing 12 of 444. All products under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K051335 | 2005-06-21 |
| K023646 | 2002-11-13 |
| K020291 | 2002-02-27 |
| K012493 | 2001-08-29 |
| K011218 | 2001-05-16 |
| K001335 | 2000-05-18 |
| K964262 | 1996-12-27 |
| K963313 | 1996-11-14 |
| K961304 | 1996-10-01 |
| K925201 | 1993-06-15 |
| K901297 | 1990-05-02 |
| K862234 | 1986-10-15 |
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Exactech, Inc. | 510(k) number | 2024-12-31 | Class II | Nonconforming Material/Component | Due to the lack of the Ethylene Vinyl Alcohol (EVOH) barrier layer. | 1446 |
| Exactech, Inc. | 510(k) number | 2023-11-21 | Class II | Packaging change control | Exactech has received 3 complaints for 4 devices related to a loss of vacuum in the inner-most vacuum bag. |
Recalls
3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2022-08-11 | Class II | Process control | Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear. | 7946 devices | |
| 2022-08-11 | Class II | Process control | Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear. | 4956 devices | |
| 2016-11-07 | Class II | Under Investigation by firm | Products were labeled with incorrect Global Trade Item Numbers. The GTIN on the label identifies the devices as another. | 79 units | 2019-08-05 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.