18 catalogue numbers from 192010, listed by Biomet Orthopedics, United States, under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented. 13 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (6), Shanghai (3), Zhejiang (2). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| b-ONE Medical (Beijing) Co., Ltd. | Beijing | Beijing | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Showing 12 of 13. All 13 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
Record
| Listed by | Biomet Orthopedics, United States |
|---|---|
| FDA product code | JDI |
| Device type | Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3350 |
| 510(k) | K070274 |
| Record published | 2015-10-24 |
| Record revised | 2025-05-30 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 192010 | 10 SIZE 130 MM TYPE I TAPER | In distribution |
| 192509 | 9 Size 125 mm Type I Taper | In distribution |
| 192520 | 20 SIZE 180 MM TYPE I TAPER | In distribution |
| 192514 | 14 Size 150 mm Type I Taper | In distribution |
| 192419 | 19 Size 175 mm Type I Taper | In distribution |
| 192416 | 16 Size 160 mm Type I Taper | In distribution |
| 192421 | 21 Size 185 mm Type I Taper | In distribution |
| 192016 | 16 Size 160 mm Type I Taper | In distribution |
| 192120 | 20 Size 180 mm Type I Taper | In distribution |
| 192519 | 19 Size 175 mm Type I Taper | In distribution |
| 110025751 | SIZE 15 TO 21 | In distribution |
| 192109 | 9 Size 125 mm Type I Taper | In distribution |
| 192114 | 14 SIZE 150 MM TYPE I TAPER | In distribution |
| 110025749 | Size 7-10 | In distribution |
| 192419 | 19 SIZE 175 MM TYPE I TAPER | In distribution |
| 192508 | 8 Size 120 mm Type I Taper | In distribution |
| 192515 | 15 Size 155 mm Type I Taper | In distribution |
| 192010 | 10 Size 130 mm Type I Taper | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented | Zimmer, Inc. | 836 |
| R3 | Smith & Nephew, Inc. | 497 |
| UniSyn Hip System | Shalby Advanced Technologies, Inc. | 247 |
| UniSyn® Hip System | Consensus Orthopedics, Inc. | 247 |
| Reflection | Smith & Nephew, Inc. | 170 |
| Instrument | Howmedica Osteonics Corp | 167 |
| Echelon | Smith & Nephew, Inc. | 159 |
| B-P Total HIP System | Endotec, Inc. | 151 |
| ZCA® | Zimmer, Inc. | 149 |
| Omnifit | Howmedica Osteonics Corp | 149 |
| Ringloc HIP System | Biomet Orthopedics | 139 |
| Profemur | Microport Orthopedics Inc. | 113 |
Showing 12 of 444. All products under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K253515 | 2026-08-24 |
| K023085 | 2002-10-17 |
| K020076 | 2002-01-30 |
Recalls Naming This Product
3 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Biomet, Inc. | 510(k) number | 2018-06-08 | Class II | Process control | Two lots of the Echo BI-Metric Hip Stem and ARCOS Modular Revision Hip Stem may have been comingled. Potential health consequences include extension of surgery time to find a replacement component. | 12 | 2020-04-14 |
| Biomet, Inc. | 510(k) number | 2017-06-05 | Class II | Labeling False and Misleading | Possibility that the patient label inside the product box was incorrectly labeled. The outer box label and actual product are correctly identified but the internal patient label could be incorrect. | 2018-03-06 | |
| Biomet, Inc. | 510(k) number | 2012-11-06 | Class II | Labeling Change Control | It was reported that the surgeon noticed that the Echo 11mm hip stem had an etching indicating it was 13mm stem. | 4 | 2013-08-28 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.