Eleos™
Eleos™ Segmental Stem, Canal Filling Straight, Slotted, Splined, 2/3 Plasma, 32MM Collar 14MM X 152MM
Who Else Makes It
Concentrated in Jiangsu (6), Shanghai (3), Zhejiang (2). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| b-ONE Medical (Beijing) Co., Ltd. | Beijing | Beijing | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Showing 12 of 13. All 13 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
Record
| Listed by | Onkos Surgical, Inc., United States |
|---|---|
| FDA product code | JDI |
| Device type | Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3350 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer |
| 510(k) | K161520 |
| Record published | 2017-04-03 |
| Record revised | 2020-04-06 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Radiation Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 26010003E | In distribution | |
| PF-2000R-02M | In distribution | |
| 25004013E | In distribution | |
| 2500CC17E | In distribution | |
| 25000001E | In distribution | |
| 25002113E | In distribution | |
| 25008013E | In distribution | |
| 2500CP14E | In distribution | |
| 25001216E | In distribution | |
| 25001050E | In distribution | |
| 25001070E | In distribution | |
| 25001210E | In distribution | |
| 26012805E | In distribution | |
| 25001060E | In distribution | |
| 26010002E | In distribution | |
| 2500SP12E | In distribution | |
| 25001090E | In distribution | |
| 2500SP18E | In distribution | |
| 25001040E | In distribution | |
| PF-2000L-02M | In distribution | |
| 25000071E | In distribution | |
| 25002205E | In distribution | |
| 25002202E | In distribution | |
| 25002114E | In distribution | |
| 2500BP18E | In distribution | |
| MS-050MM-02M | In distribution | |
| 2500BP12E | In distribution | |
| 25000091E | In distribution | |
| 2500BP14E | In distribution | |
| 2500CC11E | In distribution | |
| 25008015E | In distribution | |
| 25000051E | In distribution | |
| 25000041E | In distribution | |
| 2500CP12E | In distribution | |
| 25002111E | In distribution | |
| 2500R002E | In distribution | |
| SPSEB013E | In distribution | |
| 25000061E | In distribution | |
| 25004011E | In distribution | |
| 2500BP22E | In distribution | |
| 2500R003E | In distribution | |
| 2500BP20E | In distribution | |
| SPSE0005E | In distribution | |
| MS-040MM-02M | In distribution | |
| 25001212E | In distribution | |
| 2500R004E | In distribution | |
| MS-070MM-02M | In distribution | |
| 25001220E | In distribution | |
| 25002112E | In distribution | |
| SPSE0002E | In distribution | |
| SPSEB011E | In distribution | |
| 25004009E | In distribution | |
| 25001140E | In distribution | |
| MS-060MM-02M | In distribution | |
| 25000017E | In distribution | |
| 2500CP16E | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented | Zimmer, Inc. | 836 |
| R3 | Smith & Nephew, Inc. | 497 |
| UniSyn Hip System | Shalby Advanced Technologies, Inc. | 247 |
| UniSyn® Hip System | Consensus Orthopedics, Inc. | 247 |
| Reflection | Smith & Nephew, Inc. | 170 |
| Instrument | Howmedica Osteonics Corp | 167 |
| Echelon | Smith & Nephew, Inc. | 159 |
| B-P Total HIP System | Endotec, Inc. | 151 |
| ZCA® | Zimmer, Inc. | 149 |
| Omnifit | Howmedica Osteonics Corp | 149 |
| Ringloc HIP System | Biomet Orthopedics | 139 |
| Profemur | Microport Orthopedics Inc. | 113 |
Showing 12 of 444. All products under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K203815 | 2021-06-09 |
| K203588 | 2021-02-05 |
| K203090 | 2020-12-11 |
Recalls Naming This Product
11 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Onkos Surgical, Inc. | 510(k) number | 2025-07-11 | Class II | Under Investigation by firm | Unidentified substance of unknown impact was identified on devices during a retrospective evaluation. | 30 units | |
| Onkos Surgical, Inc. | 510(k) number | 2025-07-11 | Class II | Under Investigation by firm | Unidentified substance of unknown impact was identified on devices during a retrospective evaluation. | 15 units | |
| Onkos Surgical, Inc. | 510(k) number | 2025-07-11 | Class II | Under Investigation by firm | Unidentified substance of unknown impact was identified on devices during a retrospective evaluation. | 554 units | |
| Onkos Surgical, Inc. | 510(k) number | 2024-09-22 | Class II | Nonconforming Material/Component | Potential challenge with intraoperative assembly of the external taper of a single midsection with the internal taper of a mating proximal femur. | 24 units | |
| Onkos Surgical, Inc. | 510(k) number | 2023-09-01 | Class II | Packaging change control | Potential for breach of Tyvek seals. | 147 units | |
| Onkos Surgical, Inc. | 510(k) number | 2023-09-01 | Class II | Packaging change control | Potential for breach of Tyvek seals. | 120 units | |
| Onkos Surgical, Inc. | 510(k) number | 2023-09-01 | Class II | Packaging change control | Potential for breach of Tyvek seals. | 77 units | |
| Onkos Surgical, Inc. | 510(k) number | 2023-09-01 | Class II | Packaging change control | Potential for breach of Tyvek seals. | 99 units | |
| Onkos Surgical, Inc. | 510(k) number | 2017-05-23 | Class II | Process control | The device collar size was incorrectly labeled as 25 mm where it should be recorded as 32 mm | 4 units | 2018-06-27 |
| Onkos Surgical, Inc. | 510(k) number | 2017-05-23 | Class II | Process control | The device collar size was incorrectly labeled as 25 mm where it should be recorded as 32 mm | 4 units | 2018-06-27 |
| Onkos Surgical, Inc. | 510(k) number | 2017-05-23 | Class II | Process control | The device collar size was incorrectly labeled as 25 mm where it should be recorded as 32 mm | 4 units | 2018-06-27 |
Recalls
3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2023-12-22 | Class II | Labeling Change Control | Mislabeling of 13mm Modular Segmental Stem package (HC-13120-03M) which included an implant that was 15mm in diameter (HC-15120-03M) instead of being 13mm as stated on the package. The corresponding 15mm cemented stems were mislabeled as s | 23 units |
| 2023-12-22 | Class II | Labeling Change Control | Mislabeling of 13mm Modular Segmental Stem package (HC-13120-03M) which included an implant that was 15mm in diameter (HC-15120-03M) instead of being 13mm as stated on the package. The corresponding 15mm cemented stems were mislabeled as s | 23 units |
| 2023-09-01 | Class II | Packaging change control | Potential for breach of Tyvek seals. | 233 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.