Insert CC 28×44

Catalogue number 10063, listed by Biopro, Inc., United States, under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented. 13 manufacturers in China are registered for this product code.

Registry build 21.09.26
13manufacturers in China registered for this device type
1catalogue number
7510(k) clearances naming this product code
3recalls on this code

Who Else Makes It

Concentrated in Jiangsu (6), Shanghai (3), Zhejiang (2). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JDI
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Showing 12 of 13. All 13 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented

Record

Regulatory record for Insert CC 28X44
Listed by Biopro, Inc., United States
FDA product code JDI
Device type Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
Device class Class 2
Regulation 21 CFR 888.3350
Establishment Contract manufacturer, Repacker / relabeller, Manufacturer
510(k) K922500
Record published 2015-09-16
Record revised 2026-06-25 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Insert CC 28X44
Catalogue number Size Status
10063 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented Zimmer, Inc. 836
R3 Smith & Nephew, Inc. 497
UniSyn Hip System Shalby Advanced Technologies, Inc. 247
UniSyn® Hip System Consensus Orthopedics, Inc. 247
Reflection Smith & Nephew, Inc. 170
Instrument Howmedica Osteonics Corp 167
Echelon Smith & Nephew, Inc. 159
B-P Total HIP System Endotec, Inc. 151
ZCA® Zimmer, Inc. 149
Omnifit Howmedica Osteonics Corp 149
Ringloc HIP System Biomet Orthopedics 139
Profemur Microport Orthopedics Inc. 113

Showing 12 of 444. All products under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K090208 2009-05-22
K990821 1999-04-29
K910352 1991-06-13
K904207 1991-01-04
K882869 1988-10-14
K882146 1988-08-29
K872856 1987-08-17

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2025-09-09 Class II Package design/selection Potential packaging issue that could compromise the sterile barrier. Defect may result in loss of sterility of the device, presenting potential risk of infection if device is implanted. 147 total
2011-09-21 Not classified Packaging BioPro Femoral Head Outer Packaging was found lacking proper seal ,compromising sterility. 8 units 2013-02-15
2011-09-21 Not classified Packaging BioPro Femoral Head Outer Packaging was found lacking proper seal ,compromising sterility. 4 units 2013-02-15

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer