Ringloc BI-Polar HIP System

Catalogue number 11-165220, listed by Biomet Orthopedics, United States, under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented. 13 manufacturers in China are registered for this product code.

Registry build 21.09.26
13manufacturers in China registered for this device type
1catalogue number
3510(k) clearances naming this product code

Who Else Makes It

Concentrated in Jiangsu (6), Shanghai (3), Zhejiang (2). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JDI
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Showing 12 of 13. All 13 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented

Record

Regulatory record for Ringloc BI-Polar HIP System
Listed by Biomet Orthopedics, United States
FDA product code JDI
Device type Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
Device class Class 2
Regulation 21 CFR 888.3350
510(k) K051569
Record published 2015-10-24
Record revised 2025-05-30 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for Ringloc BI-Polar HIP System
Catalogue number Size Status
11-165220 48MM OUTER Ø 28MM INNER Ø In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented Zimmer, Inc. 836
R3 Smith & Nephew, Inc. 497
UniSyn Hip System Shalby Advanced Technologies, Inc. 247
UniSyn® Hip System Consensus Orthopedics, Inc. 247
Reflection Smith & Nephew, Inc. 170
Instrument Howmedica Osteonics Corp 167
Echelon Smith & Nephew, Inc. 159
B-P Total HIP System Endotec, Inc. 151
ZCA® Zimmer, Inc. 149
Omnifit Howmedica Osteonics Corp 149
Ringloc HIP System Biomet Orthopedics 139
Profemur Microport Orthopedics Inc. 113

Showing 12 of 444. All products under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K253515 2026-08-24
K023085 2002-10-17
K020076 2002-01-30

Recalls Naming This Product

4 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Ringloc BI-Polar HIP System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Biomet, Inc. 510(k) number 2024-05-17 Class II Labeling mix-ups 41 mm acetabular outer heads were potentially assembled with a 42 mm locking ring, may lead to joint instability leading requiring surgical intervention 12 units
Biomet, Inc. 510(k) number 2020-11-25 Class II Process control Specific lots of multiple sterile medical devices may have a breach in the sterile seal. A breach in the packaging seal could lead to loss of sterility of the device. 7428 2024-05-08
Biomet, Inc. 510(k) number 2020-09-03 Class II Process control Zimmer Biomet is conducting a medical device recall for three lots of the RingLoc Bi-Polar Hip system Acetabular Cup. The affected lots were gamma sterilized twice. Sufficient data does not exist to support the functionality, shelf life, or 48 devices 2022-12-20
Biomet, Inc. 510(k) number 2017-02-17 Class II Process design Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components. 28,253 in total 2018-01-29

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer