Ringloc TRI-Spike HIP System
6 catalogue numbers from 101007, listed by Biomet Orthopedics, United States, under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented. 13 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (6), Shanghai (3), Zhejiang (2). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| b-ONE Medical (Beijing) Co., Ltd. | Beijing | Beijing | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Showing 12 of 13. All 13 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
Record
| Listed by | Biomet Orthopedics, United States |
|---|---|
| FDA product code | JDI |
| Device type | Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3350 |
| 510(k) | K030055 |
| Record published | 2015-10-24 |
| Record revised | 2025-05-30 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 101007 | 58 MM 25 LINER SIZE | In distribution |
| 101002 | 48 MM 22 LINER SIZE | In distribution |
| 101008 | 60 MM 25 LINER SIZE | In distribution |
| 101012 | 68 MM 27 LINER SIZE | In distribution |
| 101011 | 66 MM 27 LINER SIZE | In distribution |
| 101009 | 62 MM 26 LINER SIZE | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented | Zimmer, Inc. | 836 |
| R3 | Smith & Nephew, Inc. | 497 |
| UniSyn Hip System | Shalby Advanced Technologies, Inc. | 247 |
| UniSyn® Hip System | Consensus Orthopedics, Inc. | 247 |
| Reflection | Smith & Nephew, Inc. | 170 |
| Instrument | Howmedica Osteonics Corp | 167 |
| Echelon | Smith & Nephew, Inc. | 159 |
| B-P Total HIP System | Endotec, Inc. | 151 |
| ZCA® | Zimmer, Inc. | 149 |
| Omnifit | Howmedica Osteonics Corp | 149 |
| Ringloc HIP System | Biomet Orthopedics | 139 |
| Profemur | Microport Orthopedics Inc. | 113 |
Showing 12 of 444. All products under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K253515 | 2026-08-24 |
| K023085 | 2002-10-17 |
| K020076 | 2002-01-30 |
Recalls Naming This Product
3 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Biomet, Inc. | 510(k) number | 2019-08-21 | Class II | Environmental control | Elevated levels of bacterial endotoxin and residual debris remain on the devices due to cleaning issue. | 219988 units (total) | 2021-07-21 |
| Biomet, Inc. | 510(k) number | 2015-04-16 | Class III | Labeling mix-ups | Biomet hip joint, knee joint and shoulder joint replacement components device labeling contains incorrect GTIN (Global Trade Identification Number) codes. | 1315 | 2016-05-16 |
| Biomet, Inc. | 510(k) number | 2015-01-09 | Class II | Packaging process control | Biomet recalled the Mallory Head 4 Finned Acetabular Shell 50mm (Lot 364600) and Ringloc + Acetabular Shell Limited Hole Finned 52 mm (Lot 427840) following a mix up in packaging with the two. | 17 | 2015-10-22 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.