Songer® Spinal Cable System

(1) Ø1.25mm Cable, Single Loop with Crimp, (1) Crimp, Flange, (1) Bar, Round

Registry build 21.09.26
5manufacturers in China registered for this device type
60catalogue numbers in this listing
13510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Shanghai (2), Zhejiang (2), Jiangsu (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JDQ
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38

Record

Regulatory record for Songer® Spinal Cable System
Listed by Pioneer Surgical Technology, Inc., United States
FDA product code JDQ
Device type Cerclage, Fixation
Device class Class 2
Regulation 21 CFR 888.3010
Establishment Contract manufacturer, Repacker / relabeller, Manufacturer
510(k) K935481
Record published 2016-06-25
Record revised 2026-02-09 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date
Distribution end date 2022-11-09
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Songer® Spinal Cable System
Catalogue number Size Status
400-201 In distribution
400-101 In distribution
400-114 In distribution
400-105 In distribution
400-100 In distribution
400-205 In distribution
400-104 In distribution
400-211 In distribution
400-115 In distribution
400-216 In distribution
400-207 In distribution
400-209 In distribution
400-213 In distribution
400-214 In distribution
400-218 In distribution
400-206 In distribution
400-204 In distribution
400-109 In distribution
400-200 In distribution
400-212 In distribution
400-107 In distribution
400-112 In distribution
400-210 In distribution
400-203 In distribution
400-219 In distribution
400-202 In distribution
400-113 In distribution
400-110 In distribution
400-106 In distribution
400-208 In distribution
400-111 In distribution
400-103 In distribution
400-102 In distribution
400-217 In distribution
400-108 In distribution
186.200S Withdrawn
401-540 Withdrawn
286.102S Withdrawn
00-INSTCASE Withdrawn
400-650 Withdrawn
686.302 Withdrawn
400-684 Withdrawn
286.101S Withdrawn
400-654 Withdrawn
286.100S Withdrawn
686.303 Withdrawn
186.201S Withdrawn
186.202S Withdrawn
686.304 Withdrawn
400-655 Withdrawn
986.1 Withdrawn
400-645 Withdrawn
400-651 Withdrawn
686.301 Withdrawn
400-646 Withdrawn
400-685 Withdrawn
686.303 Withdrawn
400-648 Withdrawn
400-649 Withdrawn
400-908 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Cerclage, Fixation Synthes Gmbh 102
Optilink Synthes Gmbh 61
DePuy Songer Spinal Cable System Pioneer Surgical Technology, Inc. 36
Tritium® Sternal Cable Plate System Pioneer Surgical Technology, Inc. 34
Dall-Miles Howmedica Osteonics Corp 22
Sternal Cable System Pioneer Surgical Technology, Inc. 20
Sternal Cable System A & E Medical Corporation 19
Compression Screw System Biomet Orthopedics 18
Accord Smith & Nephew, Inc. 15
Cable-Ready® Zimmer, Inc. 14
Arthrex® Arthrex, Inc. 10
Stitch Cerclage – Suture Tapes GM DOS Reis Industria E Comercio Ltda 10

Showing 12 of 56. All products under Cerclage, Fixation

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K261271 2026-07-16
K133785 2014-01-27
K002110 2000-10-06
K001709 2000-08-31
K993286 1999-11-23
K992616 1999-10-27
K980690 1998-05-22
K974016 1997-12-19
K961267 1996-06-27
K940729 1994-12-21
K941213 1994-04-19
K935481 1994-01-26
K922952 1993-02-23

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2015-05-29 Class II Labeling Change Control The box end label is incorrectly labeled as Titanium instead of Stainless Steel on one lot of implantable Songer Spinal Cable System, Single Cable, Crimp, Bar, Stainless Steel, Sterile, distributed by DePuy Spine Inc. 25 2016-03-17
2014-06-11 Class II Employee error Lack of Sterility Assurance 5 2014-10-22

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer