EasyFuse™
15 catalogue numbers from FFS21825, listed by Wright Medical Technology, Inc., United States, under Staple, Fixation, Bone. 7 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Shanghai (2), Jiangsu (2), Guangdong (1). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Sanbor Medical Xiamen, Inc. | Xiamen | Fujian | Contract manufacturer | 16 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
| Kingj Medical Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 7 |
| Hangzhou Sino-MIM Technology Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 6 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
Record
| Listed by | Wright Medical Technology, Inc., United States |
|---|---|
| FDA product code | JDR |
| Device type | Staple, Fixation, Bone |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3030 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K203832 |
| Record published | 2021-10-14 |
| Record revised | 2021-11-23 (version 2) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Sizes | Length 12 to 25 mm; width 15 to 30 mm |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| FFS21825 | Length 25 mm | In distribution |
| FFS22020 | Width 20 mm | In distribution |
| FFS4MTPS | Small | In distribution |
| FFS22015 | Width 20 mm | In distribution |
| FFS43020 | Length 20 mm | In distribution |
| FFS21512 | Length 12 mm | In distribution |
| FFS22520 | Length 20 mm | In distribution |
| FFS21520 | Width 15 mm | In distribution |
| FFS21820 | Length 20 mm | In distribution |
| FFS4MTPL | Large | In distribution |
| FFS42520 | Width 25 mm | In distribution |
| FFS22525 | Width 25 mm | In distribution |
| FFS22025 | Width 20 mm | In distribution |
| FFS21515 | Length 15 mm | In distribution |
| FFS21815 | Length 15 mm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| DynaBridge | Fusion Orthopedics, LLC | 156 |
| Arthrex® | Arthrex, Inc. | 80 |
| Staple, Fixation, Bone | Smith & Nephew, Inc. | 59 |
| Compression Staple System | Tornier Inc. | 36 |
| UNI-Clip | Newdeal Sas | 35 |
| Z-Staple | Z-Medical Gmbh & Co. KG | 34 |
| Orbitum Staple System | CPM Medical Consultants, LLC. | 32 |
| OSStaple | Biomedical Enterprises, Inc. | 30 |
| Acumed | Acumed LLC | 30 |
| Stealthfix Intraosseous Fixation System | Medartis Inc. | 29 |
| Staple, Fixation, Bone | Stryker GmbH | 29 |
| Step Boss | Biomedical Enterprises, Inc. | 27 |
Showing 12 of 319. All products under Staple, Fixation, Bone
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K203832 | 2021-05-07 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Wright Medical Technology, Inc. | 510(k) number | 2022-03-10 | Class II | Device Design | The drill and adjustable drill guide can jam/bind intraoperatively resulting in the drill guide breaking. | 176 packs | 2026-04-01 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.