Lupine Orthocord
LUPINE Loop PLUS Dual Suture (DS) Anchor w/ORTHOCORD PLA Absorbable Anchor, with two size 2 (5 metric) ORTHOCORD braided composite sutures, Violet and Blue 36 Inches (91cm). Size 2 (5…
LUPINE Loop PLUS Dual Suture (DS) Anchor w/ORTHOCORD PLA Absorbable Anchor, with two size 2 (5 metric) ORTHOCORD braided composite sutures, Violet and Blue 36 Inches (91cm). Size 2 (5 metric) ORTHOCORD eyelet loop.
Who Else Makes It
Concentrated in Shanghai (2), Jiangsu (2), Guangdong (1). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Sanbor Medical Xiamen, Inc. | Xiamen | Fujian | Contract manufacturer | 16 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
| Kingj Medical Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 7 |
| Hangzhou Sino-MIM Technology Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 6 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
Record
| Listed by | DePuy Mitek, Inc., United States |
|---|---|
| FDA product code | JDR |
| Device type | Staple, Fixation, Bone |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3030 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K062170 |
| Record published | 2015-09-01 |
| Record revised | 2025-02-17 (version 8) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Distribution end date | 2024-05-31 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 210709 | Withdrawn | |
| 210708 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| DynaBridge | Fusion Orthopedics, LLC | 156 |
| Arthrex® | Arthrex, Inc. | 80 |
| Staple, Fixation, Bone | Smith & Nephew, Inc. | 59 |
| Compression Staple System | Tornier Inc. | 36 |
| UNI-Clip | Newdeal Sas | 35 |
| Z-Staple | Z-Medical Gmbh & Co. KG | 34 |
| Orbitum Staple System | CPM Medical Consultants, LLC. | 32 |
| OSStaple | Biomedical Enterprises, Inc. | 30 |
| Acumed | Acumed LLC | 30 |
| Stealthfix Intraosseous Fixation System | Medartis Inc. | 29 |
| Staple, Fixation, Bone | Stryker GmbH | 29 |
| Step Boss | Biomedical Enterprises, Inc. | 27 |
Showing 12 of 319. All products under Staple, Fixation, Bone
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K041116 | 2004-05-28 |
| K041117 | 2004-05-28 |
| K041064 | 2004-05-13 |
| K041065 | 2004-05-07 |
Recalls Naming This Product
7 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| DePuy Mitek, Inc. | 510(k) number | 2023-04-13 | Class II | Use error | IFU Warning: Applying bending force and/or bending force with impaction to the BIOKNOTLESS Anchor Inserter may cause a fragment of the inserter tip to break off during use and be retained in the patient. broken BIOKNOTLESS Anchor inserter t | 805 units | |
| DePuy Mitek, Inc. | 510(k) number | 2023-04-13 | Class II | Use error | IFU Warning: Applying bending force and/or bending force with impaction to the BIOKNOTLESS Anchor Inserter may cause a fragment of the inserter tip to break off during use and be retained in the patient. broken BIOKNOTLESS Anchor inserter t | 540 units | |
| DePuy Mitek, Inc. | 510(k) number | 2023-04-13 | Class II | Use error | IFU Warning: Applying bending force and/or bending force with impaction to the BIOKNOTLESS Anchor Inserter may cause a fragment of the inserter tip to break off during use and be retained in the patient. broken BIOKNOTLESS Anchor inserter t | 2372 units | |
| DePuy Mitek, Inc. | 510(k) number | 2023-04-13 | Class II | Use error | IFU Warning: Applying bending force and/or bending force with impaction to the BIOKNOTLESS Anchor Inserter may cause a fragment of the inserter tip to break off during use and be retained in the patient. broken BIOKNOTLESS Anchor inserter t | 3328 units | |
| DePuy Mitek, Inc. | 510(k) number | 2023-04-13 | Class II | Use error | IFU Warning: Applying bending force and/or bending force with impaction to the BIOKNOTLESS Anchor Inserter may cause a fragment of the inserter tip to break off during use and be retained in the patient. broken BIOKNOTLESS Anchor inserter t | 1125 units | |
| DePuy Mitek, Inc. | 510(k) number | 2011-10-31 | Not classified | Employee error | Incorrect suture configuration | 299 units | 2015-08-05 |
| DePuy Mitek, Inc. | 510(k) number | 2011-10-31 | Not classified | Employee error | Incorrect suture configuration | 291 units | 2015-08-05 |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2008-04-29 | Not classified | Employee error | Lupine BR Anchor w/Orthocord was assembled with an incorrect suture configuration. The suture loop was not assembled at the distal end of the anchor. It was only threaded through the suture hole in the anchor. Risk associated with incorr | 105 units | 2008-10-02 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.