Minitac / Durabraid
Minitac TI 2.0 HS STR Anchr 2 Drbrd NDL
Who Else Makes It
Concentrated in Shanghai (2), Jiangsu (2), Guangdong (1). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Sanbor Medical Xiamen, Inc. | Xiamen | Fujian | Contract manufacturer | 16 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
| Kingj Medical Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 7 |
| Hangzhou Sino-MIM Technology Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 6 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
Record
| Listed by | Smith & Nephew, Inc., United States |
|---|---|
| FDA product code | JDR |
| Device type | Staple, Fixation, Bone |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3030 |
| Establishment | Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K000797 |
| Record published | 2015-08-30 |
| Record revised | 2023-09-07 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 7210295 | In distribution | |
| 7210303 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| DynaBridge | Fusion Orthopedics, LLC | 156 |
| Arthrex® | Arthrex, Inc. | 80 |
| Staple, Fixation, Bone | Smith & Nephew, Inc. | 59 |
| Compression Staple System | Tornier Inc. | 36 |
| UNI-Clip | Newdeal Sas | 35 |
| Z-Staple | Z-Medical Gmbh & Co. KG | 34 |
| Orbitum Staple System | CPM Medical Consultants, LLC. | 32 |
| OSStaple | Biomedical Enterprises, Inc. | 30 |
| Acumed | Acumed LLC | 30 |
| Stealthfix Intraosseous Fixation System | Medartis Inc. | 29 |
| Staple, Fixation, Bone | Stryker GmbH | 29 |
| Step Boss | Biomedical Enterprises, Inc. | 27 |
Showing 12 of 319. All products under Staple, Fixation, Bone
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K023417 | 2002-11-07 |
| K020948 | 2002-10-09 |
Recalls
9 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2013-08-06 | Class II | Packaging | Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. | 5873 US | 2016-04-20 |
| 2013-08-06 | Class II | Packaging | Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. | 6373 US | 2016-04-20 |
| 2013-08-06 | Class II | Packaging | Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. | 4946 US | 2016-04-20 |
| 2013-08-06 | Class II | Packaging | Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. | 17696 US | 2016-04-20 |
| 2013-08-06 | Class II | Packaging | Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. | 10296 US | 2016-04-20 |
| 2013-08-06 | Class II | Packaging | Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. | 18919 | 2016-04-20 |
| 2013-08-06 | Class II | Packaging | Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. | 25733 | 2016-04-20 |
| 2013-08-06 | Class II | Packaging | Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. | 4452 US | 2016-04-20 |
| 2013-08-06 | Class II | Packaging | Pinholes detected in a small number of primary pouches that may constitute a breach of the sterile barrier. | 22879 US | 2016-04-20 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.