Legion

Legion Hinge Guided Motion Tibial Insert 25MM Size 2-3 Right

Registry build 21.09.26
7manufacturers in China registered for this device type
222catalogue numbers in this listing
2510(k) clearances naming this product code
8recalls on this code

Who Else Makes It

Concentrated in Jiangsu (3), Shanghai (2), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KRO
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Record

Regulatory record for Legion
Listed by Smith & Nephew, Inc., United States
FDA product code KRO
Device type Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3510
Establishment Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K081111
Record published 2015-08-30
Record revised 2023-09-07 (version 7)

Specifications

Specifications
MRI safety MR Conditional
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date, serial number
Storage Special storage condition: : –

Catalogue Numbers

Catalogue numbers for Legion
Catalogue number Size Per pack Status
71423344 In distribution
71423328 In distribution
71421386 In distribution
XK000616-3 In distribution
71935255 In distribution
71422163 In distribution
71421902 In distribution
71422157 In distribution
71423325 In distribution
71421906 In distribution
XK000613-2 In distribution
71422159 In distribution
71935249 In distribution
XK000599-2 In distribution
XK000710-1 In distribution
E0017511-5 In distribution
71421364 In distribution
E0017511-1 In distribution
71935232 In distribution
71421363 In distribution
71421905 In distribution
71423364 In distribution
E0017511-7 In distribution
71423353 In distribution
E0015795-1 In distribution
E0016504-6 In distribution
XK000701-3 In distribution
E0017511-3 In distribution
71935245 In distribution
71422152 In distribution
71421389 In distribution
XK000629-3 In distribution
71421366 Size: 6 RIGHT In distribution
71421636 In distribution
XK000613-1 In distribution
XK000710-2 In distribution
XK000680-3 In distribution
E0015227-2 In distribution
71422154 In distribution
XK000726-3 In distribution
71422165 In distribution
XK000644-3 In distribution
XK000725-1 In distribution
XK000599-1 In distribution
71421305 In distribution
71422104 In distribution
XK000701-1 In distribution
71421937 6: 6 In distribution
71423349 In distribution
71422103 In distribution
71421303 In distribution
XK000681-2 In distribution
XK000710-3 In distribution
71421648 In distribution
71421372 2 LEFT: 2 LEFT In distribution
71421388 In distribution
71421631 In distribution
71421938 In distribution
71423351 In distribution
E0017511-4 In distribution
XK000663-1 In distribution
71423335 In distribution
E0015795-4 In distribution
XK000680-2 In distribution
XK000624-1 In distribution
71423347 In distribution
XK000633-1 In distribution
XK000642-3 In distribution
XK000726-1 In distribution
71935259 In distribution
71423338 In distribution
71423348 In distribution
71423358 In distribution
71935240 In distribution
71422101 In distribution
71423327 In distribution
XK000681-3 In distribution
71935241 In distribution
71935252 In distribution
71421365 In distribution
71423337 In distribution
XK000663-2 In distribution
XK000701-2 In distribution
XK000727-2 In distribution
71935246 In distribution
71421931 In distribution
71423341 In distribution
71421637 In distribution
71421307 In distribution
71423345 In distribution
71935231 In distribution
71935256 In distribution
71423355 In distribution
XK000725-3 In distribution
71421306 In distribution
XK000726-2 In distribution
E0016504-1 In distribution
71935234 In distribution
71421304 In distribution
XK000582-3 In distribution
71423372 In distribution
71423366 In distribution
71421933 6: 6 In distribution
E0016504-5 In distribution
E0016504-4 In distribution
71422166 In distribution
71422161 In distribution
71421632 In distribution
71421374 In distribution
71421367 In distribution
XK000662-1 In distribution
XK000616-2 In distribution
XK000642-1 In distribution
XK000616-1 In distribution
71423354 In distribution
71422158 In distribution
71422106 In distribution
XK000624-2 In distribution
71422107 In distribution
71421639 In distribution
71423329 In distribution
71423346 In distribution
71935233 In distribution
XK000663-3 In distribution
XK000629-2 In distribution
71935258 In distribution
71421385 In distribution
71935250 In distribution
XK000727-3 In distribution
71423336 In distribution
71935239 In distribution
71421903 In distribution
71423333 In distribution
E0015227-1 In distribution
71423359 In distribution
71422151 In distribution
71421904 In distribution
71423342 In distribution
XK000613-3 In distribution
71422167 In distribution
71422168 In distribution
E0016504-7 In distribution
71423371 In distribution
E0015391-1 In distribution
E0015391-3 In distribution
71422162 In distribution
71421377 In distribution
71421376 6 Left: 6 Left In distribution
E0016504-8 In distribution
71423352 In distribution
71421373 In distribution
XK000644-2 In distribution
71421375 In distribution
71935238 In distribution
E0015227-3 In distribution
E0015391-2 In distribution
71935237 In distribution
XK000636-1 In distribution
71421362 2 RIGHT: 2 RIGHT In distribution
71423365 In distribution
71421934 In distribution
XK000644-1 In distribution
XK000624-3 In distribution
E0015795-2 In distribution
71422105 In distribution
XK000681-4 In distribution
71423330 In distribution
71935242 In distribution
71422155 In distribution
71423368 In distribution
71421936 In distribution
E0015795-3 In distribution
71423363 In distribution
71423369 In distribution
71423332 In distribution
XK000727-1 In distribution
71423326 In distribution
71421638 In distribution
71423362 In distribution
XK000642-2 In distribution
71423331 In distribution
71423334 In distribution
E0015227-4 In distribution
XK000633-2 In distribution
71423357 In distribution
XK000681-1 In distribution
XK000725-2 In distribution
XK000629-1 In distribution
71423343 In distribution
71422102 In distribution
71423367 In distribution
71421935 In distribution
XK000582-1 In distribution
71421302 In distribution
71935243 In distribution
E0017511-2 In distribution
71423339 In distribution
71935253 In distribution
71422153 In distribution
71935247 In distribution
71421932 2 In distribution
71935251 In distribution
71935257 In distribution
71935235 In distribution
E0016504-2 In distribution
XK000599-3 In distribution
71421907 In distribution
71423361 In distribution
71423373 In distribution
71422164 In distribution
71423356 In distribution
E0016504-3 In distribution
E0015391-4 In distribution
71421387 In distribution
XK000582-2 In distribution
XK000680-1 In distribution
71935248 In distribution
E0017511-6 In distribution
XK000656-1 In distribution
71935244 In distribution
71422156 In distribution
E0017511-8 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Link Endo-Model EVO Knee System Waldemar Link GmbH & Co. KG 324
Endo-Model Modular Knee Prosthesis System Waldemar Link GmbH & Co. KG 291
LinkSymphoKnee Waldemar Link GmbH & Co. KG 263
Evolution Microport Orthopedics Inc. 223
OSS™ Orthopedic Salvage System Biomet Orthopedics 211
Ustar II Knee System United Orthopedic Corp. 185
“united” Ustar II Knee System United Orthopedic Corp. 162
Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer Zimmer, Inc. 157
Finn Knee System Biomet Orthopedics 138
NexGen Zimmer, Inc. 119
Triathlon Howmedica Osteonics Corp 106
Endo-Model SL Knee Prosthesis System Waldemar Link GmbH & Co. KG 94

Showing 12 of 109. All products under Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K151118 2015-07-28
K081111 2008-07-23

Recalls Naming This Product

7 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Legion
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Smith & Nephew, Inc. 510(k) number 2018-02-01 Class II Process control The screws package with devices within lot 14AAP6352A were 5 MM instead of 10MM and are too short to be used with the Legion HK Distal Wedge Size 5. 28 units 2018-10-22
Smith & Nephew, Inc. 510(k) number 2016-05-26 Class II Process control The surface inside of the femoral component, where cement is applied for adhesion, is below specification. 12 units 2019-08-16
Smith & Nephew, Inc. 510(k) number 2016-05-26 Class II Process control The surface inside of the femoral component, where cement is applied for adhesion, is below specification. 3 units 2019-08-16
Smith & Nephew, Inc. 510(k) number 2016-05-26 Class II Process control The surface inside of the femoral component, where cement is applied for adhesion, is below specification. 33 units 2019-08-16
Smith & Nephew, Inc. 510(k) number 2016-05-26 Class II Process control The surface inside of the femoral component, where cement is applied for adhesion, is below specification. 16 units 2019-08-16
Smith & Nephew, Inc. 510(k) number 2016-05-26 Class II Process control The surface inside of the femoral component, where cement is applied for adhesion, is below specification. 10 units 2019-08-16
Smith & Nephew, Inc. 510(k) number 2016-05-26 Class II Process control The surface inside of the femoral component, where cement is applied for adhesion, is below specification. 97 units 2019-08-16

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2004-06-21 Not classified Other The firm received confirmed reports of Genesis Uni Articular Inserts not locking into tibial base plates intraoperatively. 11,339 units were distributed 2006-02-15

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer