Triathlon

23 catalogue numbers from 5630-G-422-E, listed by Howmedica Osteonics Corp, United States, under Prosthesis, Knee, Patello/Femoral, Semi-Constrained, Cemented, Metal/Polymer. 7 manufacturers in China are registered for this product code.

Registry build 21.09.26
7manufacturers in China registered for this device type
23catalogue numbers in this listing
4510(k) clearances naming this product code

Who Else Makes It

Concentrated in Jiangsu (3), Shanghai (2), Zhejiang (2). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KRR
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70

Record

Regulatory record for Triathlon
Listed by Howmedica Osteonics Corp, United States
FDA product code KRR
Device type Prosthesis, Knee, Patello/Femoral, Semi-Constrained, Cemented, Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3540
Establishment Contract manufacturer, Contract steriliser, Specification developer, Manufacturer
510(k) K071881
Record published 2019-01-22
Record revised 2025-04-04 (version 6)

Specifications

Specifications
MRI safety MR Conditional
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Triathlon
Catalogue number Size Status
5630-G-422-E Side: Right Medial/Left Lateral In distribution
5630-G-408 Side: Left Medial/Right Lateral In distribution
5630-G-208-E Thickness: 8.0 Millimeter In distribution
5630-G-510-E Side: Left Medial/Right Lateral In distribution
5630-G-328 Size: 3 In distribution
5630-G-310 Side: Left Medial/Right Lateral In distribution
5630-G-208 Side: Left Medial/Right Lateral In distribution
5630-G-628 Side: Right Medial/Left Lateral In distribution
5630-G-309 Side: Left Medial/Right Lateral In distribution
5630-G-312 Size: 3 In distribution
5630-G-229-E Thickness: 9.0 Millimeter In distribution
5630-G-108-E Size: 1 In distribution
5630-G-520 Side: Right Medial/Left Lateral In distribution
5550-L-278 Type: Symetric In distribution
5630-G-412 Size: 4 In distribution
5630-G-310-E Thickness: 10.0 Millimeter In distribution
5620-B-302 Size: 3 In distribution
5630-G-222 Size: 2 In distribution
5630-G-422 Size: 4 In distribution
5610-F-301 Size: 3 In distribution
5630-G-129-E Size: 1 In distribution
5610-F-402 Size: 4 In distribution
5620-B-201 Size: 2 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Arthrex® Arthrex, Inc. 103
Restoris Mako Surgical Corp. 76
Prelude Patello-Femoral System Biomet Orthopedics 61
Prelude PF Biomet Orthopedics 59
KneeTec PFJ Corin Limited 49
HemiCAP® Arthrosurface, Inc. 48
Instrument Howmedica Osteonics Corp 48
Prelude PF Biomet Sports Medicine 21
WaveKahuna™ Arthrosurface, Inc. 16
HemiCAPWAVE® Arthrosurface, Inc. 16
Sigma Depuy (Ireland) 16
Restoris Esyntial Mako Surgical Corp. 14

Showing 12 of 47. All products under Prosthesis, Knee, Patello/Femoral, Semi-Constrained, Cemented, Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K051948 2005-10-21
K041160 2004-05-27
K020841 2002-04-11
K010100 2001-04-06

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Triathlon
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Howmedica Osteonics Corp 510(k) number 2008-11-25 Not classified Labeling mix-ups Label mix-up: Stryker Orthopaedics became aware of a lot for lot mix up between Triathlon PKR Insert X3 #1 LM/RL 8mm, 5630-G-108 lot code NXDMEE and Triathlon PKR Insert X3 #1 RM/LL- 12 mm 5630-G-122 lot code M8JMEE. 8 mm – 1 unit; 12 mm – 8 units. 2010-08-30

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer