SuperCable® Grip and Plate System
Trochanteric Grip, 6-Hole Plate, Straight
Who Else Makes It
Concentrated in Jiangsu (6), Shanghai (4), Zhejiang (3). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Turnxon Precision Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 17 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 10 |
| Hangzhou Sino-MIM Technology Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 6 |
| Suzhou AND Science & Technology Development Corp. | Zhangjiagang | Jiangsu | Contract manufacturer | 5 |
Showing 12 of 17. All 17 manufacturers in China registered for Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component
Record
| Listed by | Kinamed, Inc., United States |
|---|---|
| FDA product code | KTT |
| Device type | Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3030 |
| Establishment | Contract manufacturer, Manufacturer |
| Record published | 2015-10-28 |
| Record revised | 2025-11-20 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Label carries | lot or batch number, expiry date, manufacturing date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 35-200-1010 | In distribution | |
| 35-220-3012 | In distribution | |
| 35-220-2012 | In distribution | |
| 35-200-1040 | In distribution | |
| 35-200-1030 | In distribution | |
| 35-220-3010 | In distribution | |
| 35-860-2065 | In distribution | |
| 35-860-1020 | In distribution | |
| 35-220-1010 | In distribution | |
| 35-200-1020 | In distribution | |
| 35-220-2010 | In distribution | |
| 35-860-2020 | In distribution | |
| 35-860-2030 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Smart Correction | Wishbone Medical Inc. | 1,534 |
| Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component | Synthes Gmbh | 880 |
| LCP | Synthes Gmbh | 355 |
| Orthex External Fixation System | Orthopediatrics, Corp | 353 |
| Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component | Sterilmed, Inc. | 325 |
| CHS | Smith & Nephew, Inc. | 321 |
| Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component | Stryker Sustainability Solutions | 277 |
| Hoffmann | Stryker GmbH | 239 |
| Orthex | Orthopediatrics, Corp | 231 |
| Orthex | Vilex IN Tennessee, Inc. | 221 |
| Omega | Stryker GmbH | 212 |
| eZ-Fix | Orthopediatrics, Corp | 207 |
Showing 12 of 530. All products under Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K072250 | 2007-11-09 |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2010-08-18 | Not classified | Nonconforming Material/Component | The recall was initiated due to inadequate mechanical strength of these screwdrivers’ hexagonal tip feature, causing it to strip during final tightening. | 8 units | 2011-10-25 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.