VariAx
X-RAY Template, Dist. LAT. Fibula Plate
Who Else Makes It
Concentrated in Jiangsu (6), Shanghai (4), Zhejiang (3). 13 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Turnxon Precision Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 17 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 10 |
| Hangzhou Sino-MIM Technology Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 6 |
| Suzhou AND Science & Technology Development Corp. | Zhangjiagang | Jiangsu | Contract manufacturer | 5 |
Showing 12 of 17. All 17 manufacturers in China registered for Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component
Record
| Listed by | Stryker GmbH, Switzerland |
|---|---|
| FDA product code | KTT |
| Device type | Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3030 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer |
| Record published | 2015-09-24 |
| Record revised | 2025-11-20 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number |
| Sizes | Length 77 to 300 mm; width 430 mm |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 40-20908 | Number of Screw Holes: 8.0 Holes | In distribution |
| 45-90001 | Length 300.0 mm | In distribution |
| 40-20904 | Length 89.0 mm | In distribution |
| 40-20909 | Length 149.0 mm | In distribution |
| 40-20905 | Length 101.0 mm | In distribution |
| 40-20903 | Length 77.0 mm | In distribution |
| 40-20906 | Number of Screw Holes: 6.0 Holes | In distribution |
| 40-20907 | Number of Screw Holes: 7.0 Holes | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Smart Correction | Wishbone Medical Inc. | 1,534 |
| Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component | Synthes Gmbh | 880 |
| LCP | Synthes Gmbh | 355 |
| Orthex External Fixation System | Orthopediatrics, Corp | 353 |
| Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component | Sterilmed, Inc. | 325 |
| CHS | Smith & Nephew, Inc. | 321 |
| Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component | Stryker Sustainability Solutions | 277 |
| Hoffmann | Stryker GmbH | 239 |
| Orthex | Orthopediatrics, Corp | 231 |
| Orthex | Vilex IN Tennessee, Inc. | 221 |
| Omega | Stryker GmbH | 212 |
| eZ-Fix | Orthopediatrics, Corp | 207 |
Showing 12 of 530. All products under Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K253202 | 2025-12-19 |
| K233741 | 2023-12-21 |
| K203568 | 2021-02-01 |
| K182968 | 2019-01-25 |
| K163656 | 2017-04-14 |
| K161753 | 2016-11-15 |
| K153377 | 2016-04-11 |
| K122284 | 2012-10-24 |
| K121252 | 2012-07-25 |
| K113327 | 2012-03-29 |
| K111786 | 2012-01-26 |
Recalls
15 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2026-07-01 | Class II | Device Design | Potential cracking of the Hoffmann II Carbon Connecting Rods following cleaning and sterilization. | 9,658 units | |
| 2026-07-01 | Class II | Device Design | Potential cracking of the Hoffmann II Carbon Connecting Rods following cleaning and sterilization. | 5,439 units | |
| 2026-07-01 | Class II | Device Design | Potential cracking of the Hoffmann II Carbon Connecting Rods following cleaning and sterilization. | 5,664 units | |
| 2026-07-01 | Class II | Device Design | Potential cracking of the Hoffmann II Carbon Connecting Rods following cleaning and sterilization. | 4,505 units | |
| 2026-07-01 | Class II | Device Design | Potential cracking of the Hoffmann II Carbon Connecting Rods following cleaning and sterilization. | 9,405 units | |
| 2026-07-01 | Class II | Device Design | Potential cracking of the Hoffmann II Carbon Connecting Rods following cleaning and sterilization. | 7,571 units | |
| 2026-07-01 | Class II | Device Design | Potential cracking of the Hoffmann II Carbon Connecting Rods following cleaning and sterilization. | 6,244 units | |
| 2024-05-09 | Class II | Process change control | The adjustment ring on the device may become loose resulting in the wire tension not being able to be set correctly. | 39 devices | |
| 2023-02-07 | Class II | Process change control | Stryker has identified a nonconformance in specific lots of Hoffmann LRF Bone Transport Struts. Specifically, the thread pitch is oversized at the distal end of the threaded rod, and as a result the distal ring fixation cannot be locked bet | 488 units | |
| 2018-08-28 | Class II | Under Investigation by firm | The press fit connection of the Angular Sleeve and pin of the U-Joint and Click Lock did not meet specification. A dimensional discrepancy of the bore hole of the Angular Sleeve may cause a reduced press fit of the pin. This can result in p | 1355 | 2021-02-04 |
| 2018-08-28 | Class II | Under Investigation by firm | The press fit connection of the Angular Sleeve and pin of the U-Joint and Click Lock did not meet specification. A dimensional discrepancy of the bore hole of the Angular Sleeve may cause a reduced press fit of the pin. This can result in p | 832 | 2021-02-04 |
| 2018-08-28 | Class II | Under Investigation by firm | The press fit connection of the Angular Sleeve and pin of the U-Joint and Click Lock did not meet specification. A dimensional discrepancy of the bore hole of the Angular Sleeve may cause a reduced press fit of the pin. This can result in p | 867 | 2021-02-04 |
| 2018-08-28 | Class II | Under Investigation by firm | The press fit connection of the Angular Sleeve and pin of the U-Joint and Click Lock did not meet specification. A dimensional discrepancy of the bore hole of the Angular Sleeve may cause a reduced press fit of the pin. This can result in p | 578 | 2021-02-04 |
| 2018-07-26 | Class II | Under Investigation by firm | When creating a correction plan with the Correct Axial First button selected and the No. of corrections per day set to more than 1 (e.g., 2, 3, or 4), the Hexapod Software computes an erroneously accelerated correction plan for the axial | 233 | 2020-05-26 |
| 2018-03-12 | Class II | Labeling mix-ups | The wrong parts were picked for packaging. The connecting Nuts were packed in the packaging labeled with Hinge coupling | 18 | 2020-05-21 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.