Prosthesis, Elbow, Hemi-, Radial, Polymer

Offset Stem Inserter/Extractor FOR Radial Head Prosthesis

Registry build 21.09.26
3manufacturers in China registered for this device type
43catalogue numbers in this listing

Who Else Makes It

Concentrated in Shanghai (2), Jiangsu (1).

Chinese manufacturers registered for FDA product code KWI
Manufacturer City Province Registered as Device types
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34

Record

Regulatory record for Prosthesis, Elbow, Hemi-, Radial, Polymer
Listed by Synthes Gmbh, Switzerland
FDA product code KWI
Device type Prosthesis, Elbow, Hemi-, Radial, Polymer
Device class Class 2
Regulation 21 CFR 888.3170
Establishment Specification developer, Manufacturer, Exporter
510(k) K183618
Record published 2020-06-08
Record revised 2024-09-11 (version 9)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Prosthesis, Elbow, Hemi-, Radial, Polymer
Catalogue number Size Status
09.405.260S In distribution
09.405.586S In distribution
09.405.276S In distribution
03.402.717 In distribution
03.402.722 In distribution
09.405.253S In distribution
09.405.963S In distribution
03.402.719 In distribution
03.402.720 In distribution
09.405.583S In distribution
09.405.966S In distribution
09.405.566S In distribution
09.405.950S In distribution
03.402.740 In distribution
09.405.263S In distribution
09.405.960S In distribution
09.405.573S In distribution
03.402.718 In distribution
09.405.250S In distribution
09.405.280S In distribution
09.405.956S In distribution
09.405.563S In distribution
09.405.560S In distribution
03.402.723 In distribution
03.402.741 In distribution
03.402.725 In distribution
09.405.580S In distribution
09.405.273S In distribution
03.405.000S In distribution
09.405.976S In distribution
09.405.256S In distribution
03.402.721 In distribution
03.402.716 In distribution
09.405.953S In distribution
09.405.576S In distribution
09.405.973S In distribution
09.405.970S In distribution
09.405.286S In distribution
09.405.266S In distribution
09.405.270S In distribution
09.405.283S In distribution
03.402.724 In distribution
09.405.570S In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Acumed Acumed LLC 175
Align Skeletal Dynamics L.L.C. 97
Prosthesis, Elbow, Hemi-, Radial, Polymer Synthes (U.S.A.) LP 78
Evolve Wright Medical Technology, Inc. 75
Rhead Stryker GmbH 53
L2L™ Zimmer, Inc. 48
Explor Biomet Orthopedics 32
Avenger IN2BONES USA, LLC 32
BioPoly® Radial Head Implant Biopoly, LLC 30
Seitz Solution Radial Head Kapp Surgical Instrument, Inc. 27
Integra® Ascension Orthopedics, Inc. 23
Modular Radial Head (MRH) System Smith & Nephew, Inc. 22

Showing 12 of 28. All products under Prosthesis, Elbow, Hemi-, Radial, Polymer

Recalls Naming This Product

3 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Prosthesis, Elbow, Hemi-, Radial, Polymer
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Synthes (USA) Products LLC 510(k) number 2022-04-07 Class II Labeling Change Control DePuy Synthes Radial Head Replacement System Contraindications added to Electronic Instructions for Use (e-IFU): Absolute contraindications include: Infection, sepsis, osteomyelitis.
Synthes (USA) Products LLC 510(k) number 2016-12-29 Class II Under Investigation by firm There is the possibility that the radial stem may loosen post-operatively at the stem bone interface. 50,311 units 2018-02-06
Synthes USA (HQ), Inc. 510(k) number 2013-02-22 Class II Device Design The Trial Head may come loose from the implant stem during manipulation of the arm during surgery. To date, no adverse events have been reported related to this issue and this recall is not being initiated as a result of adverse events. 417 2015-08-31

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker