Taperloc Complete Primary Femoral

13 catalogue numbers from 51-100130, listed by Biomet Orthopedics, United States, under Prosthesis, Hip, Hemi-, Femoral, Metal. 10 manufacturers in China are registered for this product code.

Registry build 21.09.26
10manufacturers in China registered for this device type
13catalogue numbers in this listing

Who Else Makes It

Concentrated in Jiangsu (4), Shanghai (3), Zhejiang (2). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KWL
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34

Record

Regulatory record for Taperloc Complete Primary Femoral
Listed by Biomet Orthopedics, United States
FDA product code KWL
Device type Prosthesis, Hip, Hemi-, Femoral, Metal
Device class Class 2
Regulation 21 CFR 888.3360
510(k) K101086
Record published 2018-12-19
Record revised 2025-05-30 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for Taperloc Complete Primary Femoral
Catalogue number Size Status
51-100130 13X146MM STANDARD OFFSET TYPE 1 TAPER In distribution
51-100050 5X130MM STANDARD OFFSET TYPE 1 TAPER In distribution
51-100240 24X167MM STANDARD OFFSET TYPE 1 TAPER In distribution
51-100080 8X136MM STANDARD OFFSET TYPE 1 TAPER In distribution
51-104090 9X137MM HIGH OFFSET TYPE 1 TAPER In distribution
51-104200 20X160MM HIGH OFFSET TYPE 1 TAPER In distribution
51-103140 14X148MM STANDARD OFFSET TYPE 1 TAPER In distribution
51-100150 15X150MM STANDARD OFFSET TYPE 1 TAPER In distribution
51-100120 12X144MM STANDARD OFFSET TYPE 1 TAPER In distribution
51-103120 12X144MM STANDARD OFFSET TYPE 1 TAPER In distribution
51-103160 16X152MM STANDARD OFFSET TYPE 1 TAPER In distribution
51-103130 13X146MM STANDARD OFFSET TYPE 1 TAPER In distribution
51-100090 9X137MM STANDARD OFFSET TYPE 1 TAPER In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Ustar II Knee System United Orthopedic Corp. 115
Consensus Hip System Shalby Advanced Technologies, Inc. 95
Consensus® Hip System Consensus Orthopedics, Inc. 95
Instrument Howmedica Osteonics Corp 94
UHR Howmedica Osteonics Corp 75
Austin Moore Howmedica Osteonics Corp 67
B-P Total HIP System Endotec, Inc. 66
CS2 Acetabular Cup System Consensus Orthopedics, Inc. 64
DJO Surgical Encore Medical, L.P. 62
Restoration Howmedica Osteonics Corp 56
Optimom Modular Heads Corin Limited 49
Corin Unipolar Modular Head Corin Limited 36

Showing 12 of 167. All products under Prosthesis, Hip, Hemi-, Femoral, Metal

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker