VerSys®
13 catalogue numbers from 7818-45, listed by Zimmer, Inc., United States, under Prosthesis, Hip, Hemi-, Femoral, Metal. 10 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (4), Shanghai (3), Zhejiang (2). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
Record
| Listed by | Zimmer, Inc., United States |
|---|---|
| FDA product code | KWL |
| Device type | Prosthesis, Hip, Hemi-, Femoral, Metal |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3360 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter |
| 510(k) | K955473 |
| Record published | 2015-09-17 |
| Record revised | 2020-06-10 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Sizes | Outer diameter 10 to 16 mm |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 7818-45 | 12/14 Taper, 45 mm Diameter | In distribution |
| 7818-41 | 12/14 Taper, 41 mm Diameter | In distribution |
| 7818-40 | 12/14 Taper, 40 mm Diameter | In distribution |
| 7859-13 | Outer Diameter 13 mm | In distribution |
| 7859-11 | Outer Diameter 11 mm | In distribution |
| 7818-52 | 12/14 Taper, 52 mm Diameter | In distribution |
| 7859-10 | Outer Diameter 10 mm | In distribution |
| 7818-60 | 12/14 Taper, 60 mm Diameter | In distribution |
| 7834-15 | 12/14 Neck Taper, Size 15, 140 mm Stem Length | In distribution |
| 7818-53 | 12/14 Taper, 53 mm Diameter | In distribution |
| 7859-16 | Outer Diameter 16 mm | In distribution |
| 7818-38 | 12/14 Taper, 38 mm Diameter | In distribution |
| 7818-42 | 12/14 Taper, 42 mm Diameter | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Ustar II Knee System | United Orthopedic Corp. | 115 |
| Consensus Hip System | Shalby Advanced Technologies, Inc. | 95 |
| Consensus® Hip System | Consensus Orthopedics, Inc. | 95 |
| Instrument | Howmedica Osteonics Corp | 94 |
| UHR | Howmedica Osteonics Corp | 75 |
| Austin Moore | Howmedica Osteonics Corp | 67 |
| B-P Total HIP System | Endotec, Inc. | 66 |
| CS2 Acetabular Cup System | Consensus Orthopedics, Inc. | 64 |
| DJO Surgical | Encore Medical, L.P. | 62 |
| Restoration | Howmedica Osteonics Corp | 56 |
| Optimom Modular Heads | Corin Limited | 49 |
| Corin Unipolar Modular Head | Corin Limited | 36 |
Showing 12 of 167. All products under Prosthesis, Hip, Hemi-, Femoral, Metal
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K823051 | 1982-12-03 |
| K811416 | 1981-08-12 |
Recalls Naming This Product
5 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Zimmer Manufacturing B.V. | 510(k) number | 2016-01-11 | Class II | Packaging | As a result of the insufficient sealer calibration data for product packaged in firm’s Building II between August 2010 and April 2013. The affected products are sterile. | 2,239 | 2017-04-13 |
| Zimmer Manufacturing B.V. | 510(k) number | 2016-01-11 | Class II | Packaging | As a result of the insufficient sealer calibration data for product packaged in firm’s Building II between August 2010 and April 2013. The affected products are sterile. | 5013 | 2017-04-13 |
| Zimmer Manufacturing B.V. | 510(k) number | 2016-01-11 | Class II | Packaging | As a result of the insufficient sealer calibration data for product packaged in firm’s Building II between August 2010 and April 2013. The affected products are sterile. | 2388 | 2017-04-13 |
| Zimmer, Inc. | 510(k) number | 2014-07-22 | Class II | Package design/selection | Zimmer is recalling sterile-packaged implants and instruments packaged in six different package configurations due to packaging design verification test failures. Specifically, multiple test samples from each of the six configurations faile | 972,125 units | 2015-09-15 |
| Zimmer, Inc. | 510(k) number | 2013-10-11 | Class II | Packaging | Zimmer recently conducted a review of all historic packaging validations at its Zimmer Manufacturing B.V. (ZMBV) facility in Ponce, Puerto Rico. Based on this review, it was determined that the packaging operations conducted in the Building | 7,044,680 total | 2017-04-14 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.