Expedium
EXPEDIUM SPINE SYSTEM SLOTTED CONNECTOR FOR POLYAXIAL BOLT, MINI OFFSET LEFT 5.5/6.35mm
Who Else Makes It
Concentrated in Jiangsu (5), Shandong (2), Shanghai (1). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
| Double Medical Technology Inc. | Xiamen | Fujian | Contract manufacturer | 14 |
| Zhejiang Decans Medical Devices Co., Ltd. | Jiaxing | Zhejiang | Manufacturer | 10 |
Record
| Listed by | Medos International Sàrl, Switzerland |
|---|---|
| FDA product code | KWP |
| Device type | Appliance, Fixation, Spinal Interlaminal |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3050 |
| 510(k) | K101993 |
| Record published | 2015-09-24 |
| Record revised | 2025-07-02 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Distribution end date | 2024-06-14 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 179771130 | In distribution | |
| 188167300 | In distribution | |
| 179712545 | In distribution | |
| 179712255 | In distribution | |
| 179902740 | In distribution | |
| 179970070 | In distribution | |
| 175460080 | In distribution | |
| 175465050 | In distribution | |
| 179712750S | In distribution | |
| 179912899 | In distribution | |
| 179771050 | In distribution | |
| 179712660 | In distribution | |
| 179902425 | In distribution | |
| 179988535 | In distribution | |
| 188155255 | In distribution | |
| 179902420 | In distribution | |
| 179788640 | In distribution | |
| 179932540 | In distribution | |
| 175460020 | In distribution | |
| 179722450 | In distribution | |
| 188163800 | In distribution | |
| 179706099 | In distribution | |
| 188161032 | In distribution | |
| 186162381S | In distribution | |
| 179712540S | In distribution | |
| 179988730 | In distribution | |
| 189680300 | In distribution | |
| 179712655S | In distribution | |
| 179992150 | In distribution | |
| 179988540 | In distribution | |
| 179794030 | In distribution | |
| 179912970 | In distribution | |
| 179722735 | In distribution | |
| 188198020 | In distribution | |
| 179712135 | In distribution | |
| 179766555 | In distribution | |
| 179762381 | In distribution | |
| 179912670 | In distribution | |
| 187722632 | In distribution | |
| 185430400 | In distribution | |
| 179912080 | In distribution | |
| 175422845 | In distribution | |
| 175450145 | In distribution | |
| 175453041 | In distribution | |
| 179952018 | In distribution | |
| 179940100 | In distribution | |
| 179702740 | In distribution | |
| 179998060 | In distribution | |
| 179788530 | In distribution | |
| 179932630 | In distribution | |
| 179932655 | In distribution | |
| 179712295 | In distribution | |
| 179712865 | In distribution | |
| 179762120S | In distribution | |
| 179952210 | In distribution | |
| 175412545 | In distribution | |
| 179715530 | In distribution | |
| 175462655 | In distribution | |
| 188165355 | In distribution | |
| 179952010 | In distribution | |
| 188193020 | In distribution | |
| 179912190 | In distribution | |
| 179732635 | In distribution | |
| 179932855 | In distribution | |
| 179722555 | In distribution | |
| 179902730 | In distribution | |
| 175412945 | In distribution | |
| 179942048 | In distribution | |
| 179712880 | In distribution | |
| 179902640 | In distribution | |
| 179788520 | In distribution | |
| 179902845 | In distribution | |
| 179732450 | In distribution | |
| 179771060 | In distribution | |
| 188182050 | In distribution | |
| 175450030 | In distribution | |
| 179797040 | In distribution | |
| 179722870 | In distribution | |
| 179788440 | In distribution | |
| 179997040 | In distribution | |
| 179902860 | In distribution | |
| 179732745 | In distribution | |
| 179784035 | In distribution | |
| 179998100 | In distribution | |
| 179972040 | In distribution | |
| 179997020 | In distribution | |
| 179752195 | In distribution | |
| 179702450 | In distribution | |
| 188167600 | In distribution | |
| 179788730 | In distribution | |
| 179752026 | In distribution | |
| 179702000 | In distribution | |
| 179732730 | In distribution | |
| 179722130 | In distribution | |
| 179712845 | In distribution | |
| 186262455 | In distribution | |
| 175417640 | In distribution | |
| 179912185 | In distribution | |
| 179788750 | In distribution | |
| 179912830 | In distribution | |
| 188115540 | In distribution | |
| 179712999 | In distribution | |
| 179722990 | In distribution | |
| 179702865 | In distribution | |
| 179771140 | In distribution | |
| 179992100 | In distribution | |
| 179752040 | In distribution | |
| 179912750 | In distribution | |
| 186162382S | In distribution | |
| 179712755 | In distribution | |
| 179712520 | In distribution | |
| 179788550 | In distribution | |
| 179702430 | In distribution | |
| 179771065 | In distribution | |
| 179798020 | In distribution | |
| 175465010 | In distribution | |
| 175465101 | In distribution | |
| 175452039 | In distribution | |
| 175452008 | In distribution | |
| 179712290 | In distribution | |
| 175422950 | In distribution | |
| 179783530 | In distribution | |
| 179963450 | In distribution | |
| 175462630 | In distribution | |
| 179788425 | In distribution | |
| 179784100 | In distribution | |
| 175462640 | In distribution | |
| 175450120 | In distribution | |
| 179762380S | In distribution | |
| 179702545 | In distribution | |
| 179752010 | In distribution | |
| 175465005 | In distribution | |
| 179970055 | In distribution | |
| 189662300 | In distribution | |
| 188169502 | In distribution | |
| 179722000 | In distribution | |
| 179712885 | In distribution | |
| 179762382S | In distribution | |
| 179794020 | In distribution | |
| 179784065 | In distribution | |
| 179788755 | In distribution | |
| 188174350 | In distribution | |
| 179792150 | In distribution | |
| 179988440 | In distribution | |
| 179912650 | In distribution | |
| 179752240 | In distribution | |
| 179792200 | In distribution | |
| 175443035 | In distribution | |
| 179732540 | In distribution | |
| 179722430 | In distribution | |
| 179722140 | In distribution | |
| 179712745S | In distribution | |
| 179990001 | In distribution | |
| 179912645 | In distribution | |
| 179932835 | In distribution | |
| 179912550 | In distribution | |
| 179912760 | In distribution | |
| 189697060 | In distribution | |
| 179942036 | In distribution | |
| 179722850 | In distribution | |
| 179722950 | In distribution | |
| 179712455 | In distribution | |
| 179988750 | In distribution | |
| 189640200 | In distribution | |
| 175412745 | In distribution | |
| 179712899 | In distribution | |
| 179784120 | In distribution | |
| 175422935 | In distribution | |
| 175462650 | In distribution | |
| 179702780 | In distribution | |
| 175450020 | In distribution | |
| 175460040 | In distribution | |
| 189661036 | In distribution | |
| 189688540 | Withdrawn | |
| 189612425 | Withdrawn | |
| 175443008 | Withdrawn | |
| 188188525 | Withdrawn | |
| 175465103 | Withdrawn | |
| 179993050 | Withdrawn | |
| 179902760 | Withdrawn | |
| 185462650 | Withdrawn | |
| 185462850 | Withdrawn | |
| 185422645 | Withdrawn | |
| 189632425 | Withdrawn | |
| 189652130 | Withdrawn | |
| 189619775 | Withdrawn | |
| 188188435 | Withdrawn | |
| 188188520 | Withdrawn | |
| 185422035 | Withdrawn | |
| 188119780 | Withdrawn | |
| 188152220 | Withdrawn | |
| 189622000 | Withdrawn | |
| 179902850 | Withdrawn | |
| 185430255 | Withdrawn | |
| 185462745 | Withdrawn | |
| 189662060 | Withdrawn | |
| 175430600 | Withdrawn | |
| 189652200 | Withdrawn | |
| 179942045 | Withdrawn | |
| 175432035 | Withdrawn | |
| 189652210 | Withdrawn | |
| 189612760 | Withdrawn | |
| 189618535 | Withdrawn | |
| 189602855 | Withdrawn | |
| 188142036 | Withdrawn | |
| 185452006 | Withdrawn | |
| 188122180 | Withdrawn | |
| 189640001 | Withdrawn | |
| 188116530 | Withdrawn | |
| 185422425 | Withdrawn | |
| 189662070 | Withdrawn | |
| 179912095 | Withdrawn | |
| 185462835 | Withdrawn | |
| 188122955 | Withdrawn | |
| 175412055 | Withdrawn | |
| 179799745 | Withdrawn | |
| 185417640 | Withdrawn | |
| 185417650 | Withdrawn | |
| 175432055 | Withdrawn | |
| 189612755 | Withdrawn | |
| 185450555 | Withdrawn | |
| 188145255 | Withdrawn | |
| 189612080 | Withdrawn | |
| 175443006 | Withdrawn | |
| 188122845 | Withdrawn | |
| 188152045 | Withdrawn | |
| 185422730 | Withdrawn | |
| 189612535 | Withdrawn | |
| 189612035 | Withdrawn | |
| 188152016 | Withdrawn | |
| 189652230 | Withdrawn | |
| 175412550 | Withdrawn | |
| 185432935 | Withdrawn | |
| 185426080 | Withdrawn | |
| 185422990 | Withdrawn | |
| 185462735 | Withdrawn | |
| 185432645 | Withdrawn | |
| 188122050 | Withdrawn | |
| 188112110 | Withdrawn | |
| 185422540 | Withdrawn | |
| 189688420 | Withdrawn | |
| 185455032 | Withdrawn | |
| 188192125 | Withdrawn | |
| 189652026 | Withdrawn | |
| 185443049 | Withdrawn | |
| 175432630 | Withdrawn | |
| 185462840 | Withdrawn | |
| 189692200 | Withdrawn | |
| 185450030 | Withdrawn | |
| 179799450 | Withdrawn |
Showing 250 of 289 catalogue numbers.
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Invictus | Alphatec Spine, Inc. | 5,422 |
| ReLine | Nuvasive, Inc. | 4,439 |
| CD Horizon® Spinal System | Medtronic Sofamor Danek, Inc. | 3,188 |
| Creo | Globus Medical, Inc. | 1,992 |
| Apex Spine System | Spinecraft LLC | 1,319 |
| LnK Spinal Fixation System | L&K Biomed Co., Ltd. | 1,271 |
| Perla ® TL | Spineart SA | 1,035 |
| Astra Spine System | Spinecraft LLC | 1,003 |
| LineSider | Highridge Medical, LLC | 948 |
| Apex-DL Spine System | Spinecraft LLC | 909 |
| Revere | Globus Medical, Inc. | 875 |
| AccelFix Spinal Fixation System | L&K Biomed Co., Ltd. | 841 |
Showing 12 of 536. All products under Appliance, Fixation, Spinal Interlaminal
Recalls Naming This Product
9 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Depuy Spine, Inc. | 510(k) number | 2015-04-21 | Class II | Process design | Device does not mate as intended. | 183 devices | 2018-10-03 |
| Depuy Spine, Inc. | 510(k) number | 2012-11-07 | Class II | Component change control | Polyaxial screws 8x 80 and larger may disassociate when inserting in the Ilium., VIPER large diameter long screws in high-torque circumstances, the screw shank has the potential to separate from the polyaxial head | 34 units | 2013-12-24 |
| Depuy Spine, Inc. | 510(k) number | 2012-11-07 | Class II | Component change control | Polyaxial screws 8x 80 and larger may disassociate when inserting in the Ilium., VIPER large diameter long screws in high-torque circumstances, the screw shank has the potential to separate from the polyaxial head | 36 units | 2013-12-24 |
| Depuy Spine, Inc. | 510(k) number | 2012-11-07 | Class II | Component change control | Polyaxial screws 8x 80 and larger may disassociate when inserting in the Ilium., VIPER large diameter long screws in high-torque circumstances, the screw shank has the potential to separate from the polyaxial head | 2013-12-24 | |
| Depuy Spine, Inc. | 510(k) number | 2012-11-07 | Class II | Component change control | Polyaxial screws 8x 80 and larger may disassociate when inserting in the Ilium., VIPER large diameter long screws in high-torque circumstances, the screw shank has the potential to separate from the polyaxial head | 24 units | 2013-12-24 |
| Depuy Spine, Inc. | 510(k) number | 2012-11-07 | Class II | Component change control | Polyaxial screws 8x 80 and larger may disassociate when inserting in the Ilium., VIPER large diameter long screws in high-torque circumstances, the screw shank has the potential to separate from the polyaxial head | 34 uits | 2013-12-24 |
| Depuy Spine, Inc. | 510(k) number | 2012-11-07 | Class II | Component change control | Polyaxial screws 8x 80 and larger may disassociate when inserting in the Ilium., VIPER large diameter long screws in high-torque circumstances, the screw shank has the potential to separate from the polyaxial head | 23 units | 2013-12-24 |
| Depuy Spine, Inc. | 510(k) number | 2012-11-07 | Class II | Component change control | Polyaxial screws 8x 80 and larger may disassociate when inserting in the Ilium., VIPER large diameter long screws in high-torque circumstances, the screw shank has the potential to separate from the polyaxial head | 6 units | 2013-12-24 |
| Depuy Spine, Inc. | 510(k) number | 2012-11-07 | Class II | Component change control | Polyaxial screws 8x 80 and larger may disassociate when inserting in the ilium. VIPER large diameter long screws in high-torque circumstances, the screw shank has the potential to separate from the polyaxial head. | 10 units | 2013-12-24 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.