Expedium SFX
EXPEDIUM SFX CROSS CONNECTOR SYSTEM LATERAL CONNECTOR - F13 6.35 x 47mm
Who Else Makes It
Concentrated in Jiangsu (5), Shandong (2), Shanghai (1). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
| Double Medical Technology Inc. | Xiamen | Fujian | Contract manufacturer | 14 |
| Zhejiang Decans Medical Devices Co., Ltd. | Jiaxing | Zhejiang | Manufacturer | 10 |
Record
| Listed by | Depuy Spine, Inc., United States |
|---|---|
| FDA product code | KWP |
| Device type | Appliance, Fixation, Spinal Interlaminal |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3050 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K070300 |
| Record published | 2015-09-24 |
| Record revised | 2025-07-02 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number |
| Distribution end date | 2018-12-31 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 189407242 | In distribution | |
| 189403404 | In distribution | |
| 189401211 | In distribution | |
| 189401302 | In distribution | |
| 189401114 | In distribution | |
| 189401104 | In distribution | |
| 189401106 | In distribution | |
| 189401212 | In distribution | |
| 189403302 | In distribution | |
| 189403212 | In distribution | |
| 189403210 | In distribution | |
| 189402210 | Withdrawn | |
| 189404113 | Withdrawn | |
| 189404405 | Withdrawn | |
| 189404108 | Withdrawn | |
| 189408224 | Withdrawn | |
| 189408122 | Withdrawn | |
| 189404208 | Withdrawn | |
| 189402405 | Withdrawn | |
| 189404110 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Invictus | Alphatec Spine, Inc. | 5,422 |
| ReLine | Nuvasive, Inc. | 4,439 |
| CD Horizon® Spinal System | Medtronic Sofamor Danek, Inc. | 3,188 |
| Creo | Globus Medical, Inc. | 1,992 |
| Apex Spine System | Spinecraft LLC | 1,319 |
| LnK Spinal Fixation System | L&K Biomed Co., Ltd. | 1,271 |
| Perla ® TL | Spineart SA | 1,035 |
| Astra Spine System | Spinecraft LLC | 1,003 |
| LineSider | Highridge Medical, LLC | 948 |
| Apex-DL Spine System | Spinecraft LLC | 909 |
| Revere | Globus Medical, Inc. | 875 |
| AccelFix Spinal Fixation System | L&K Biomed Co., Ltd. | 841 |
Showing 12 of 536. All products under Appliance, Fixation, Spinal Interlaminal
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K110353 | 2011-04-07 |
| K070300 | 2007-04-10 |
| K052131 | 2005-09-28 |
| K042508 | 2004-10-07 |
| K041119 | 2004-07-19 |
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Depuy Spine, Inc. | 510(k) number | 2015-04-21 | Class II | Process design | Device does not mate as intended. | 183 devices | 2018-10-03 |
| Depuy Spine, Inc. | 510(k) number | 2009-02-11 | Not classified | Nonconforming Material/Component | Tip of Driver may break during use | 117 units | 2015-07-09 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.