Leucadia Pedicle Screw System

POLYAXIAL REDUCTION SCREW, 6 x 50mm

Registry build 21.09.26
11manufacturers in China registered for this device type
18catalogue numbers in this listing
4510(k) clearances naming this product code
6recalls on this code

Who Else Makes It

Concentrated in Jiangsu (5), Shandong (2), Shanghai (1). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KWP
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Zibo Dante Co., Ltd. Zibo Shandong Contract manufacturer 17
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34
Double Medical Technology Inc. Xiamen Fujian Contract manufacturer 14
Zhejiang Decans Medical Devices Co., Ltd. Jiaxing Zhejiang Manufacturer 10

Record

Regulatory record for Leucadia Pedicle Screw System
Listed by Alphatec Spine, Inc., United States
FDA product code KWP
Device type Appliance, Fixation, Spinal Interlaminal
Device class Class 2
Regulation 21 CFR 888.3050
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K110588
Record published 2014-09-24
Record revised 2025-07-14 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Single use Yes
Prescription Prescription only
Label carries lot or batch number
Sizes Outer diameter 4.5 to 8 mm; length 25 to 100 mm; width 37 mm
Distribution end date 2017-11-10
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Leucadia Pedicle Screw System
Catalogue number Size Status
LC-PR0650 Outer Diameter 6 mm Withdrawn
LC-PS0535 Length 35 mm Withdrawn
CO-HSS1011 Withdrawn
LC-PR0565 Length 65 mm Withdrawn
LC-PS0860 Length 60 mm Withdrawn
LC-PS0660 Outer Diameter 6 mm Withdrawn
LC-PS0635 Length 35 mm Withdrawn
LC-CR5580 Outer Diameter 5.5 mm Withdrawn
LG-CC1001 Width 37 mm Withdrawn
LC-PS0565 Length 65 mm Withdrawn
LC-PS4525 Length 25 mm Withdrawn
LC-CR5540 Outer Diameter 5.5 mm Withdrawn
LC-PR0835 Length 35 mm Withdrawn
LC-CR5585 Length 85 mm Withdrawn
LC-PR0550 Outer Diameter 5 mm Withdrawn
LC-PS0765 Length 65 mm Withdrawn
LC-CR55100 Outer Diameter 5.5 mm Withdrawn
RD-PB5510 Length 100 mm Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Invictus Alphatec Spine, Inc. 5,422
ReLine Nuvasive, Inc. 4,439
CD Horizon® Spinal System Medtronic Sofamor Danek, Inc. 3,188
Creo Globus Medical, Inc. 1,992
Apex Spine System Spinecraft LLC 1,319
LnK Spinal Fixation System L&K Biomed Co., Ltd. 1,271
Perla ® TL Spineart SA 1,035
Astra Spine System Spinecraft LLC 1,003
LineSider Highridge Medical, LLC 948
Apex-DL Spine System Spinecraft LLC 909
Revere Globus Medical, Inc. 875
AccelFix Spinal Fixation System L&K Biomed Co., Ltd. 841

Showing 12 of 536. All products under Appliance, Fixation, Spinal Interlaminal

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K103205 2011-06-02
K100685 2010-06-18
K072081 2007-10-24
K052201 2005-11-10

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Leucadia Pedicle Screw System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Allez Spine, LLC 510(k) number 2008-08-21 Not classified Pending This action is being taken voluntarily as a result of a Warning Letter issued to AlIez Spine LLC by the Food & Drug Administration. The Company decided it could better address the FDA’s concerns regarding Current Good Manufacturing Practice 6472 units for all systems 2010-01-19

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2011-07-06 Class II Process control The rods were incorrectly laser etched as ILLICO Straight CP Tl Rods, 110mm, when they were in fact manufactured to 100mm in length. 7 2013-03-20
2010-12-09 Class II Error in labeling The recall was initiated because Alphatec Spine confirmed that the TI Standard Polyaxial Screw Assembly was laser marked with the incorrect length of 45 MM. 11 units 2012-11-09
2010-11-01 Not classified Device Design These lots were not manufactured correctly in that the instrument does not have the durability required to repeatedly perform over its full service life and, therefore, may experience breakage in the tips. 27 units 2012-01-31
2009-08-05 Not classified Process control Alphatec Spine discovered that the affected lots were not manufactured correctly in that the screw body portion of the assembly has only 22.5 degrees of angulation in the east-west plane instead of the designed 38-40 degrees. 163 Units 2010-06-07
2009-08-05 Not classified Process control Alphatec Spine discovered that the affected lots were not manufactured correctly in that the screw body portion of the assembly has only 22.5 degrees of angulation in the east-west plane instead of the designed 38-40 degrees. 158 units 2010-06-07
2008-11-03 Not classified Error in labeling Alphatec Spine recently discovered that this lot of screws has the incorrect length laser etched on one side of the screw body. As a result, they are conducting a voluntary recall of the Zodiac Titanium cannulated polyaxial screw 6.5 mm x 56 2009-12-08

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer