Pass Tulip
CLOSED ILIAC CONNECTOR - 100 mm
Who Else Makes It
Concentrated in Jiangsu (5), Shandong (2), Shanghai (1). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
| Double Medical Technology Inc. | Xiamen | Fujian | Contract manufacturer | 14 |
| Zhejiang Decans Medical Devices Co., Ltd. | Jiaxing | Zhejiang | Manufacturer | 10 |
Record
| Listed by | Medicrea International, France |
|---|---|
| FDA product code | KWP |
| Device type | Appliance, Fixation, Spinal Interlaminal |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3050 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K182240 |
| Record published | 2018-11-07 |
| Record revised | 2025-07-02 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Distribution end date | 2023-01-10 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| B22066102 | Withdrawn | |
| B22066106 | Withdrawn | |
| B22066010 | Withdrawn | |
| B22066005 | Withdrawn | |
| B22066105 | Withdrawn | |
| B22066103 | Withdrawn | |
| B22066006 | Withdrawn | |
| B22066110 | Withdrawn | |
| B22066002 | Withdrawn | |
| B22066003 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Invictus | Alphatec Spine, Inc. | 5,422 |
| ReLine | Nuvasive, Inc. | 4,439 |
| CD Horizon® Spinal System | Medtronic Sofamor Danek, Inc. | 3,188 |
| Creo | Globus Medical, Inc. | 1,992 |
| Apex Spine System | Spinecraft LLC | 1,319 |
| LnK Spinal Fixation System | L&K Biomed Co., Ltd. | 1,271 |
| Perla ® TL | Spineart SA | 1,035 |
| Astra Spine System | Spinecraft LLC | 1,003 |
| LineSider | Highridge Medical, LLC | 948 |
| Apex-DL Spine System | Spinecraft LLC | 909 |
| Revere | Globus Medical, Inc. | 875 |
| AccelFix Spinal Fixation System | L&K Biomed Co., Ltd. | 841 |
Showing 12 of 536. All products under Appliance, Fixation, Spinal Interlaminal
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K121979 | 2013-03-21 |
| K062181 | 2007-01-16 |
| K032094 | 2003-11-14 |
Recalls
4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2020-01-28 | Class II | Process control | An internal component was assembled in the incorrect orientation, which may lead to the tulip head disengaging from the crew shank during or after screw insertion, or during the reduction step. | 3529 | 2023-03-17 |
| 2020-01-28 | Class II | Process control | An internal component was assembled in the incorrect orientation, which may lead to the tulip head disengaging from the crew shank during or after screw insertion, or during the reduction step. | 3529 | 2023-03-17 |
| 2019-09-16 | Class II | Process control | Conical Cannulated Screws may not accept 1.6mm K-Wire, it cannot enter the minimum tolerance axis threaded | 30 units | |
| 2019-09-16 | Class II | Process control | Conical Cannulated Screws may not accept 1.6mm K-Wire, it cannot enter the minimum tolerance axis threaded | 190 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.