Zodiac Spinal Fixation System
Ti 4.0mm Standard Uniplanar Screw Assembly 4.0mm x 50mm
Who Else Makes It
Concentrated in Jiangsu (5), Shandong (2), Shanghai (1). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
| Double Medical Technology Inc. | Xiamen | Fujian | Contract manufacturer | 14 |
| Zhejiang Decans Medical Devices Co., Ltd. | Jiaxing | Zhejiang | Manufacturer | 10 |
Record
| Listed by | Alphatec Spine, Inc., United States |
|---|---|
| FDA product code | KWP |
| Device type | Appliance, Fixation, Spinal Interlaminal |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3050 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K051286 |
| Record published | 2015-08-31 |
| Record revised | 2025-07-14 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number |
| Sizes | Length 30 to 100 mm; outer diameter 4 to 8.5 mm |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 82085-90 | Length 90 mm | In distribution |
| 42075-80 | Outer Diameter 7.5 mm | In distribution |
| 82085-100 | Length 100 mm | In distribution |
| 62110-60 | Length 60 mm | In distribution |
| 82972-30 | Outer Diameter 6.35 mm | In distribution |
| 62085-100 | Outer Diameter 8.5 mm | In distribution |
| 82110-30 | Length 30 mm | In distribution |
| 62007-02 | In distribution | |
| 82085-95 | Length 95 mm | In distribution |
| 22040-50 | Outer Diameter 4 mm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Invictus | Alphatec Spine, Inc. | 5,422 |
| ReLine | Nuvasive, Inc. | 4,439 |
| CD Horizon® Spinal System | Medtronic Sofamor Danek, Inc. | 3,188 |
| Creo | Globus Medical, Inc. | 1,992 |
| Apex Spine System | Spinecraft LLC | 1,319 |
| LnK Spinal Fixation System | L&K Biomed Co., Ltd. | 1,271 |
| Perla ® TL | Spineart SA | 1,035 |
| Astra Spine System | Spinecraft LLC | 1,003 |
| LineSider | Highridge Medical, LLC | 948 |
| Apex-DL Spine System | Spinecraft LLC | 909 |
| Revere | Globus Medical, Inc. | 875 |
| AccelFix Spinal Fixation System | L&K Biomed Co., Ltd. | 841 |
Showing 12 of 536. All products under Appliance, Fixation, Spinal Interlaminal
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K103205 | 2011-06-02 |
| K100685 | 2010-06-18 |
| K072081 | 2007-10-24 |
| K052201 | 2005-11-10 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Alphatec Spine, Inc. | 510(k) number | 2010-12-09 | Class II | Error in labeling | The recall was initiated because Alphatec Spine confirmed that the TI Standard Polyaxial Screw Assembly was laser marked with the incorrect length of 45 MM. | 11 units | 2012-11-09 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2011-07-06 | Class II | Process control | The rods were incorrectly laser etched as ILLICO Straight CP Tl Rods, 110mm, when they were in fact manufactured to 100mm in length. | 7 | 2013-03-20 |
| 2010-11-01 | Not classified | Device Design | These lots were not manufactured correctly in that the instrument does not have the durability required to repeatedly perform over its full service life and, therefore, may experience breakage in the tips. | 27 units | 2012-01-31 |
| 2009-08-05 | Not classified | Process control | Alphatec Spine discovered that the affected lots were not manufactured correctly in that the screw body portion of the assembly has only 22.5 degrees of angulation in the east-west plane instead of the designed 38-40 degrees. | 163 Units | 2010-06-07 |
| 2009-08-05 | Not classified | Process control | Alphatec Spine discovered that the affected lots were not manufactured correctly in that the screw body portion of the assembly has only 22.5 degrees of angulation in the east-west plane instead of the designed 38-40 degrees. | 158 units | 2010-06-07 |
| 2008-11-03 | Not classified | Error in labeling | Alphatec Spine recently discovered that this lot of screws has the incorrect length laser etched on one side of the screw body. As a result, they are conducting a voluntary recall of the Zodiac Titanium cannulated polyaxial screw 6.5 mm x | 56 | 2009-12-08 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.