Kaneda SR

KANEDA SR ANTERIOR SYSTEM BLUNT TIP CLOSED SCREW 6.35 x 6.25 x 35mm

Registry build 21.09.26
14manufacturers in China registered for this device type
69catalogue numbers in this listing
10510(k) clearances naming this product code
8recalls on this code

Who Else Makes It

Concentrated in Jiangsu (5), Shanghai (3), Zhejiang (2). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KWQ
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Zibo Dante Co., Ltd. Zibo Shandong Contract manufacturer 17
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34
Double Medical Technology Inc. Xiamen Fujian Contract manufacturer 14

Showing 12 of 14. All 14 manufacturers in China registered for Appliance, Fixation, Spinal Intervertebral Body

Record

Regulatory record for Kaneda SR
Listed by Depuy Spine, Inc., United States
FDA product code KWQ
Device type Appliance, Fixation, Spinal Intervertebral Body
Device class Class 2
Regulation 21 CFR 888.3060
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K971248
Record published 2015-09-24
Record revised 2025-07-02 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Single use Yes
Prescription Prescription only
Label carries lot or batch number
Distribution end date 2018-06-20

Catalogue Numbers

Catalogue numbers for Kaneda SR
Catalogue number Size Status
32101525C In distribution
52012430 Withdrawn
52102425 Withdrawn
52002445 Withdrawn
52012445 Withdrawn
52113245 Withdrawn
52102445 Withdrawn
52103545 Withdrawn
52012450 Withdrawn
52113265 Withdrawn
52103230 Withdrawn
52113530 Withdrawn
52103540 Withdrawn
52113270 Withdrawn
52002825 Withdrawn
52111930 Withdrawn
52113555 Withdrawn
52103250 Withdrawn
52002850 Withdrawn
52102435 Withdrawn
52112435 Withdrawn
52113540 Withdrawn
52103245 Withdrawn
52102430 Withdrawn
52002425 Withdrawn
52101935 Withdrawn
52103555 Withdrawn
52002835 Withdrawn
52012830 Withdrawn
52002830 Withdrawn
52102455 Withdrawn
52113550 Withdrawn
52111940 Withdrawn
52012850 Withdrawn
52002430 Withdrawn
52102450 Withdrawn
52103535 Withdrawn
52012425 Withdrawn
52113240 Withdrawn
52112450 Withdrawn
52002440 Withdrawn
52112425 Withdrawn
52002840 Withdrawn
52113525 Withdrawn
52112430 Withdrawn
52012845 Withdrawn
52113545 Withdrawn
52002435 Withdrawn
52113535 Withdrawn
52111935 Withdrawn
52103255 Withdrawn
52012835 Withdrawn
52112440 Withdrawn
52103260 Withdrawn
52103240 Withdrawn
52113250 Withdrawn
52102835MB Withdrawn
52103550 Withdrawn
52113260 Withdrawn
52102440 Withdrawn
52112445 Withdrawn
52012840 Withdrawn
52012435 Withdrawn
52012440 Withdrawn
52112455 Withdrawn
52113255 Withdrawn
52113230 Withdrawn
52113235 Withdrawn
52002845 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
ReLine Nuvasive, Inc. 2,998
CD Horizon® Spinal System Medtronic Sofamor Danek, Inc. 2,568
Creo Globus Medical, Inc. 1,765
AccelFix Spinal Fixation System L&K Biomed Co., Ltd. 1,755
Ozark Cervical Plate System VB Spine LLC 1,460
Sirion Astura Medical 1,246
Apex Spine System Spinecraft LLC 1,187
AnyPlus Spinal Fixation System GS Medical Co., Ltd. 986
Astra Spine System Spinecraft LLC 970
Zavation Zavation 966
ACP Nuvasive, Inc. 918
Polaris™ 5.5 Spinal System Biomet Spine 877

Showing 12 of 855. All products under Appliance, Fixation, Spinal Intervertebral Body

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K100070 2010-02-04
K082273 2008-09-10
K080191 2008-04-02
K072546 2007-10-05
K070994 2007-05-09
K052546 2006-02-03
K052552 2005-10-13
K042544 2004-11-23
K041205 2004-08-17
K040655 2004-06-02

Recalls

8 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2016-10-12 Class II Under Investigation by firm SKYLINE Variable Ti screws may have contained SKYLINE Constrained Ti screws within the packaging. 1 unit 2017-09-18
2016-10-12 Class II Under Investigation by firm SKYLINE Variable Ti screws may have contained SKYLINE Constrained Ti screws within the packaging. 14 units 2017-09-18
2016-10-12 Class II Under Investigation by firm SKYLINE Variable Ti screws may have contained SKYLINE Constrained Ti screws within the packaging. 6 units 2017-09-18
2016-10-12 Class II Under Investigation by firm SKYLINE Variable Ti screws may have contained SKYLINE Constrained Ti screws within the packaging. 9 units 2017-09-18
2016-10-12 Class II Under Investigation by firm SKYLINE Variable Ti screws may have contained SKYLINE Constrained Ti screws within the packaging. 12 units 2017-09-18
2016-10-12 Class II Under Investigation by firm SKYLINE Variable Ti screws may have contained SKYLINE Constrained Ti screws within the packaging. 9 units 2017-09-18
2016-10-12 Class II Under Investigation by firm SKYLINE Variable Ti screws may have contained SKYLINE Constrained Ti screws within the packaging. 21 units 2017-09-18
2015-11-20 Class II Device Design Manufacturing error within the Torque Handle may prohibit some handles from being able to fully assemble with the tightener shaft. The design of the inspection gage does not account for the additional shift length 16 devices 2017-07-03

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer