Mariner MCT

Constrained Rod, 100mm, Precontoured

Registry build 21.09.26
14manufacturers in China registered for this device type
10catalogue numbers in this listing
5510(k) clearances naming this product code

Who Else Makes It

Concentrated in Jiangsu (5), Shanghai (3), Zhejiang (2). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KWQ
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Zibo Dante Co., Ltd. Zibo Shandong Contract manufacturer 17
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34
Double Medical Technology Inc. Xiamen Fujian Contract manufacturer 14

Showing 12 of 14. All 14 manufacturers in China registered for Appliance, Fixation, Spinal Intervertebral Body

Record

Regulatory record for Mariner MCT
Listed by Seaspine Orthopedics Corporation, United States
FDA product code KWQ
Device type Appliance, Fixation, Spinal Intervertebral Body
Device class Class 2
Regulation 21 CFR 888.3060
Establishment Specification developer, Complaint-file establishment, Manufacturer
510(k) K222110
Record published 2025-12-29

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Single use Yes
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Mariner MCT
Catalogue number Size Status
MC1-200100 In distribution
MC1-150050 In distribution
MC1-175040 In distribution
MC1-200075 In distribution
MC1-200110 In distribution
MC1-145040 In distribution
MC1-200040 In distribution
MC1-160035 In distribution
MC1-165025 In distribution
MC1-175045 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
ReLine Nuvasive, Inc. 2,998
CD Horizon® Spinal System Medtronic Sofamor Danek, Inc. 2,568
Creo Globus Medical, Inc. 1,765
AccelFix Spinal Fixation System L&K Biomed Co., Ltd. 1,755
Ozark Cervical Plate System VB Spine LLC 1,460
Sirion Astura Medical 1,246
Apex Spine System Spinecraft LLC 1,187
AnyPlus Spinal Fixation System GS Medical Co., Ltd. 986
Astra Spine System Spinecraft LLC 970
Zavation Zavation 966
ACP Nuvasive, Inc. 918
Polaris™ 5.5 Spinal System Biomet Spine 877

Showing 12 of 855. All products under Appliance, Fixation, Spinal Intervertebral Body

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K212139 2021-09-01
K211903 2021-08-30
K202064 2020-08-26
K200885 2020-05-28
K173521 2018-01-24

Recalls Naming This Product

2 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Mariner MCT
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Seaspine Orthopedics Corporation 510(k) number 2024-02-28 Class II Nonconforming Material/Component Screw heads, of pedicle screw systems, have partial thread within the screw head that pose a risk of intraoperative cross-threading within the locking cap/screw head interface. 444 Screw Heads
Seaspine Orthopedics Corporation 510(k) number 2024-02-15 Class II Nonconforming Material/Component Screw heads, of pedicle screw systems, have thin lead-in thread that pose a risk of intraoperative cross-threading within the locking cap/screw head interface. 1579 Screw Heads

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker