Mariner MIS
Mariner MIS Wayfinder Tray, Level 1
Who Else Makes It
Concentrated in Jiangsu (5), Shanghai (3), Zhejiang (2). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
| Double Medical Technology Inc. | Xiamen | Fujian | Contract manufacturer | 14 |
Showing 12 of 14. All 14 manufacturers in China registered for Appliance, Fixation, Spinal Intervertebral Body
Record
| Listed by | Seaspine Orthopedics Corporation, United States |
|---|---|
| FDA product code | KWQ |
| Device type | Appliance, Fixation, Spinal Intervertebral Body |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3060 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer |
| 510(k) | K191648 |
| Record published | 2024-03-06 |
| Record revised | 2025-10-24 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| MM1-116210 | In distribution | |
| MM1-166450 | In distribution | |
| MM3-100051 | In distribution | |
| MM2-101912 | In distribution | |
| MM3-000036 | In distribution | |
| MM1-176060 | In distribution | |
| MM3-000011 | In distribution | |
| MM2-001912 | In distribution | |
| MM2-000935 | In distribution | |
| MM1-125050 | In distribution | |
| MM1-146075 | In distribution | |
| MM1-175160 | In distribution | |
| MM2-000900 | In distribution | |
| MM1-125070 | In distribution | |
| MM1-116095 | In distribution | |
| MM1-125040 | In distribution | |
| MM1-115030 | In distribution | |
| MM1-145120 | In distribution | |
| MM1-166170 | In distribution | |
| MM1-166150 | In distribution | |
| MM1-175210 | In distribution | |
| MM3-000052 | In distribution | |
| MM1-176180 | In distribution | |
| MM1-156095 | In distribution | |
| MM1-166080 | In distribution | |
| MM1-165120 | In distribution | |
| MM3-000030 | In distribution | |
| MM1-125100 | In distribution | |
| MM1-176075 | In distribution | |
| MM2-001911 | In distribution | |
| MM1-125060 | In distribution | |
| MM1-165090 | In distribution | |
| MM1-175200 | In distribution | |
| MM1-116300 | In distribution | |
| MM1-175060 | In distribution | |
| MM2-100955 | In distribution | |
| MM1-115090 | In distribution | |
| MM1-155095 | In distribution | |
| MM2-100945 | In distribution | |
| MM3-000021 | In distribution | |
| MM1-146060 | In distribution | |
| MM1-165110 | In distribution | |
| MM1-115190 | In distribution | |
| MM1-115160 | In distribution | |
| MM1-115170 | In distribution | |
| MM1-166350 | In distribution | |
| MM1-165200 | In distribution | |
| MM1-126090 | In distribution | |
| MM1-165350 | In distribution | |
| MM1-116350 | In distribution | |
| MM1-146055 | In distribution | |
| MM1-156075 | In distribution | |
| MM1-175110 | In distribution | |
| MM1-126065 | In distribution | |
| MM1-176160 | In distribution | |
| MM1-176095 | In distribution | |
| MM1-175170 | In distribution | |
| MM1-116230 | In distribution | |
| MM1-145055 | In distribution | |
| MM1-166085 | In distribution | |
| MM1-175075 | In distribution | |
| MM1-176210 | In distribution | |
| MM3-000050 | In distribution | |
| MM1-146080 | In distribution | |
| MM2-000960 | In distribution | |
| MM1-116050 | In distribution | |
| MM2-100530 | In distribution | |
| MM1-175095 | In distribution | |
| MM1-155070 | In distribution | |
| MM1-145030 | In distribution | |
| MM1-176035 | In distribution | |
| MM1-166025 | In distribution | |
| MM1-115065 | In distribution | |
| MM1-145050 | In distribution | |
| MM1-165075 | In distribution | |
| MM1-155055 | In distribution | |
| MM1-176110 | In distribution | |
| MM1-156035 | In distribution | |
| MM1-176065 | In distribution | |
| MM1-115150 | In distribution | |
| MM1-175100 | In distribution | |
| MM2-000180 | In distribution | |
| MM1-116040 | In distribution | |
| MM1-175050 | In distribution | |
| MM1-165045 | In distribution | |
| MM1-116400 | In distribution | |
| MM1-116055 | In distribution | |
| MM1-165025 | In distribution | |
| MM1-115450 | In distribution | |
| MM2-100912 | In distribution | |
| MM1-176070 | In distribution | |
| MM2-100950 | In distribution | |
| MM1-146035 | In distribution | |
| MM1-115200 | In distribution | |
| MM1-155090 | In distribution | |
| MM1-155040 | In distribution | |
| MM2-000945 | In distribution | |
| MM1-166400 | In distribution | |
| MM1-126095 | In distribution | |
| MM1-115095 | In distribution | |
| MM1-165180 | In distribution | |
| MM1-176150 | In distribution | |
| MM1-166040 | In distribution | |
| MM1-155060 | In distribution | |
| MM1-125130 | In distribution | |
| MM1-165250 | In distribution | |
| MM1-156040 | In distribution | |
| MM2-100935 | In distribution | |
| MM2-000913 | In distribution | |
| MM1-155035 | In distribution | |
| MM1-166130 | In distribution | |
| MM3-000053 | In distribution | |
| MM1-166300 | In distribution | |
| MM1-166250 | In distribution | |
| MM1-116060 | In distribution | |
| MM1-165190 | In distribution | |
| MM2-000930 | In distribution | |
| MM1-155050 | In distribution | |
| MM2-100913 | In distribution | |
| MM1-175045 | In distribution | |
| MM1-165055 | In distribution | |
| MM2-101913 | In distribution | |
| MM1-116090 | In distribution | |
| MM3-000012 | In distribution | |
| MM1-115085 | In distribution | |
| MM1-176190 | In distribution | |
| MM1-126100 | In distribution | |
| MM2-102913 | In distribution | |
| MM1-125110 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| ReLine | Nuvasive, Inc. | 2,998 |
| CD Horizon® Spinal System | Medtronic Sofamor Danek, Inc. | 2,568 |
| Creo | Globus Medical, Inc. | 1,765 |
| AccelFix Spinal Fixation System | L&K Biomed Co., Ltd. | 1,755 |
| Ozark Cervical Plate System | VB Spine LLC | 1,460 |
| Sirion | Astura Medical | 1,246 |
| Apex Spine System | Spinecraft LLC | 1,187 |
| AnyPlus Spinal Fixation System | GS Medical Co., Ltd. | 986 |
| Astra Spine System | Spinecraft LLC | 970 |
| Zavation | Zavation | 966 |
| ACP | Nuvasive, Inc. | 918 |
| Polaris™ 5.5 Spinal System | Biomet Spine | 877 |
Showing 12 of 855. All products under Appliance, Fixation, Spinal Intervertebral Body
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K212139 | 2021-09-01 |
| K211903 | 2021-08-30 |
| K202064 | 2020-08-26 |
| K200885 | 2020-05-28 |
| K173521 | 2018-01-24 |
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Seaspine Orthopedics Corporation | 510(k) number | 2024-02-28 | Class II | Nonconforming Material/Component | Screw heads, of pedicle screw systems, have partial thread within the screw head that pose a risk of intraoperative cross-threading within the locking cap/screw head interface. | 444 Screw Heads |
| Seaspine Orthopedics Corporation | 510(k) number | 2024-02-15 | Class II | Nonconforming Material/Component | Screw heads, of pedicle screw systems, have thin lead-in thread that pose a risk of intraoperative cross-threading within the locking cap/screw head interface. | 1579 Screw Heads |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.