SiLo™ Spinal System
FAS FOR 5.5MM ROD, 5.0X30, TI
Who Else Makes It
Concentrated in Jiangsu (5), Shanghai (3), Zhejiang (2). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
| Double Medical Technology Inc. | Xiamen | Fujian | Contract manufacturer | 14 |
Showing 12 of 14. All 14 manufacturers in China registered for Appliance, Fixation, Spinal Intervertebral Body
Record
| Listed by | Medtronic Sofamor Danek, Inc., United States |
|---|---|
| FDA product code | KWQ |
| Device type | Appliance, Fixation, Spinal Intervertebral Body |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3060 |
| 510(k) | K042210 |
| Record published | 2015-08-04 |
| Record revised | 2025-07-02 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number |
| Sizes | Outer diameter 5 mm; length 30 mm |
| Distribution end date | 2018-10-08 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 8892230 | Outer Diameter 5.0 mm | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| ReLine | Nuvasive, Inc. | 2,998 |
| CD Horizon® Spinal System | Medtronic Sofamor Danek, Inc. | 2,568 |
| Creo | Globus Medical, Inc. | 1,765 |
| AccelFix Spinal Fixation System | L&K Biomed Co., Ltd. | 1,755 |
| Ozark Cervical Plate System | VB Spine LLC | 1,460 |
| Sirion | Astura Medical | 1,246 |
| Apex Spine System | Spinecraft LLC | 1,187 |
| AnyPlus Spinal Fixation System | GS Medical Co., Ltd. | 986 |
| Astra Spine System | Spinecraft LLC | 970 |
| Zavation | Zavation | 966 |
| ACP | Nuvasive, Inc. | 918 |
| Polaris™ 5.5 Spinal System | Biomet Spine | 877 |
Showing 12 of 855. All products under Appliance, Fixation, Spinal Intervertebral Body
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K140417 | 2014-07-09 |
| K081038 | 2008-08-15 |
| K063100 | 2007-02-23 |
| K061274 | 2006-05-25 |
| K050117 | 2005-02-17 |
| K043151 | 2005-02-01 |
| K031782 | 2005-02-01 |
| K042922 | 2004-11-19 |
| K042499 | 2004-10-07 |
| K042235 | 2004-09-17 |
| K042025 | 2004-08-25 |
| K041217 | 2004-05-28 |
| K040962 | 2004-05-14 |
| K032265 | 2003-08-11 |
| K030327 | 2003-02-26 |
| K021761 | 2002-09-17 |
| K021461 | 2002-07-22 |
| K021226 | 2002-05-13 |
| K013665 | 2002-01-29 |
| K994239 | 2000-06-19 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Medtronic Sofamor Danek Instrument Manufacturing | 510(k) number | 2006-12-18 | Not classified | Other | Due to a manufacturing error, the proximal end may deform causing the protrusions that engage the associated implant to break off of the instrument during use. | 58 units | 2007-07-16 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.