Aequalis™ Fx2
24 catalogue numbers from DWH443B, listed by Tornier Inc., United States, under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented. 9 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (5), Shanghai (3), Zhejiang (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 10 |
| Stryker Trauson (Changzhou) Medical Technology Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 3 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
Record
| Listed by | Tornier Inc., United States |
|---|---|
| FDA product code | KWS |
| Device type | Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3660 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K141345 |
| Record published | 2015-10-16 |
| Record revised | 2018-09-07 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | expiry date, serial number |
| Sizes | Outer diameter 7 to 42 mm; angle 12.5 °; length 90 to 170 mm |
| Distribution end date | 2017-10-25 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| DWH443B | Angle 12.5 ° | Withdrawn |
| DWK206B | Angle 12.5 ° | Withdrawn |
| DWH426B | Outer Diameter 15 mm | Withdrawn |
| DWH446B | Angle 12.5 ° | Withdrawn |
| DWK122B | Length 130 mm | Withdrawn |
| DWH542B | Angle 12.5 ° | Withdrawn |
| DWH561B | Outer Diameter 42 mm | Withdrawn |
| DWH541B | Thickness +6 mm | Withdrawn |
| DWK272B | Angle 12.5 ° | Withdrawn |
| DWH565B | Angle 12.5 ° | Withdrawn |
| DWH464B | Thickness +6 mm | Withdrawn |
| DWH544B | Angle 12.5 ° | Withdrawn |
| DWH463B | Angle 12.5 ° | Withdrawn |
| DWH442B | Thickness +9 mm | Withdrawn |
| DWH412B | Length 130 mm | Withdrawn |
| DWK131B | Outer Diameter 7 mm | Withdrawn |
| DWH466B | Thickness +12 mm | Withdrawn |
| DWH461B | Angle 12.5 ° | Withdrawn |
| DWK226B | Outer Diameter 36 mm | Withdrawn |
| DWH416B | Length 130 mm | Withdrawn |
| DWH403B | Outer Diameter 9 mm | Withdrawn |
| DWH462B | Angle 12.5 ° | Withdrawn |
| DWK125B | Outer Diameter 13 mm | Withdrawn |
| DWK124B | Outer Diameter 11 mm | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Equinoxe | Exactech, Inc. | 442 |
| Reunion | Stryker GmbH | 321 |
| DJO Surgical | Encore Medical, L.P. | 266 |
| SMR Shoulder | Limacorporate | 209 |
| Tornier Flex Shoulder System | Tornier Inc. | 187 |
| Anatomical Shoulder™ | Zimmer, Inc. | 166 |
| Arthrex® | Arthrex, Inc. | 154 |
| Comprehensive Shoulder System | Biomet Orthopedics | 111 |
| Flex Shoulder System | Tornier Inc. | 109 |
| Aequalis™ PerFORM+ | Tornier Inc. | 108 |
| Aequalis™ Ascend™ Flex | Tornier Inc. | 102 |
| Anatomic Shoulder Prosthesis | Medacta International SA | 90 |
Showing 12 of 326. All products under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K260721 | 2026-07-22 |
| K191318 | 2019-06-14 |
| K181420 | 2018-09-20 |
| K160975 | 2016-06-10 |
| K150583 | 2015-04-23 |
| K121493 | 2012-06-20 |
| K120794 | 2012-04-13 |
| K113413 | 2012-03-09 |
| K111902 | 2011-11-03 |
| K110865 | 2011-04-27 |
| K102924 | 2011-01-31 |
| K103007 | 2010-11-09 |
| K082120 | 2008-10-24 |
| K081707 | 2008-07-17 |
| K060209 | 2006-03-02 |
| K043077 | 2004-12-17 |
| K041339 | 2004-06-17 |
| K032679 | 2003-12-15 |
| K012212 | 2001-08-15 |
| K003728 | 2000-12-20 |
| K994393 | 2000-06-22 |
| K994392 | 2000-03-10 |
| K980244 | 1999-08-23 |
| K952928 | 1995-09-27 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Tornier Inc. | 510(k) number | 2016-09-19 | Class II | Component design/selection | Tornier is conducting a recall on Aequalis Fx2 ( implant parts and instrument trays) due to reports of dislocations of the poly insert and the stem. | 30 | 2018-05-31 |
Recalls
5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2026-03-05 | Class II | Labeling design | Affected products were incorrectly labeled as Tornier HRS Max products. These parts are compatible with the Tornier HRS system only, and are incompatible with the Tornier HRS Max system. | 233 | |
| 2025-12-19 | Class II | Labeling mix-ups | A specific lot of screws is incorrectly labeled. Screws are labeled as 5.0mmx18mm but actual screws are 5.00mmx14mm. If mismatch is detected during surgery, the issue may cause a minor delay in surgery. If not detected and incorrect screw i | 427 | |
| 2023-06-12 | Class II | Under Investigation by firm | A comingle/swap resulted in the labeling and laser marking on the product to state it is a Aequalis Flex Revive Assembly Screw 0mm Standard (ARS655101) but it was a Aequalis Flex Revive Assembly Screw 0mm Short (ARS655118) & vice versa. | 55 units | |
| 2023-06-12 | Class II | Under Investigation by firm | A comingle/swap resulted in the labeling and laser marking on the product to state it is a Aequalis Flex Revive Assembly Screw 0mm Standard (ARS655101) but it was a Aequalis Flex Revive Assembly Screw 0mm Short (ARS655118) & vice versa. | 55 units | |
| 2021-05-28 | Class II | Employee error | Two lots have been swapped thus have the incorrect product in the package. The component may be of a different thickness. | 20 | 2023-04-14 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.