Aequalis Reversed II

55 catalogue numbers from DWE845, listed by Tornier Inc., United States, under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented. 9 manufacturers in China are registered for this product code.

Registry build 21.09.26
9manufacturers in China registered for this device type
55catalogue numbers in this listing
24510(k) clearances naming this product code
6recalls on this code

Who Else Makes It

Concentrated in Jiangsu (5), Shanghai (3), Zhejiang (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KWS
Manufacturer City Province Registered as Device types
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
Stryker Trauson (Changzhou) Medical Technology Co., Ltd. Changzhou Jiangsu Contract manufacturer 3
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34

Record

Regulatory record for Aequalis Reversed II
Listed by Tornier Inc., United States
FDA product code KWS
Device type Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
Device class Class 2
Regulation 21 CFR 888.3660
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter
Record published 2015-10-16
Record revised 2022-08-15 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries expiry date, manufacturing date, serial number
Sizes Outer diameter 25 to 42 mm; length 20 to 50 mm

Catalogue Numbers

Catalogue numbers for Aequalis Reversed II
Catalogue number Size Status
DWE845 Length 45 mm In distribution
DWD184 Outer Diameter 42 mm In distribution
DWE880 Outer Diameter 36 mm In distribution
DWE862 Eccentric: +2mm In distribution
DWD981 Outer Diameter 42 mm In distribution
DWE720 Length 20 mm In distribution
DWD183 Outer Diameter 42 mm In distribution
DWE871 Outer Diameter 42 mm In distribution
DWD195 Outer Diameter 42 mm In distribution
DWH919 Eccentric: +2mm In distribution
DWD990 Outer Diameter 36 mm In distribution
DWD180 Outer Diameter 36 mm In distribution
DWD194 Outer Diameter 42 mm In distribution
DWE735 Length 35 mm In distribution
DWE872 Outer Diameter 42 mm In distribution
DWE870 Outer Diameter 42 mm In distribution
DWE860 Outer Diameter 36 mm In distribution
DWH906 Eccentric: +2mm In distribution
DWD190 Outer Diameter 36 mm In distribution
DWE861 Outer Diameter 36 mm In distribution
DWE725 Length 25 mm In distribution
DWE892 Outer Diameter 42 mm In distribution
DWD170 Outer Diameter 25 mm In distribution
DWE730 Outer Diameter 25 mm In distribution
DWE825 Length 25 mm In distribution
DWH914 Outer Diameter 39 mm In distribution
DWD982 Outer Diameter 36 mm In distribution
DWD193 Outer Diameter 42 mm In distribution
DWD181 Outer Diameter 36 mm In distribution
DWD988 Outer Diameter 36 mm In distribution
DWE835 Outer Diameter 29 mm In distribution
DWE740 Length 40 mm In distribution
DWD983 Outer Diameter 42 mm In distribution
DWD987 Outer Diameter 42 mm In distribution
DWH911 Lateralized: +4mm In distribution
DWE820 Length 20 mm In distribution
DWD989 Outer Diameter 36 mm In distribution
DWD171 Outer Diameter 25 mm In distribution
DWD185 Outer Diameter 42 mm In distribution
DWD182 Outer Diameter 36 mm In distribution
DWE881 Lateralized: +4mm In distribution
DWE891 Lateralized: +4mm In distribution
DWD984 Outer Diameter 36 mm In distribution
DWD985 Outer Diameter 42 mm In distribution
DWD191 Outer Diameter 36 mm In distribution
DWD986 Outer Diameter 36 mm In distribution
DWE750 Length 50 mm In distribution
DWE850 Outer Diameter 29 mm In distribution
DWE882 Outer Diameter 36 mm In distribution
DWE830 Length 30 mm In distribution
DWE745 Outer Diameter 25 mm In distribution
DWD192 Outer Diameter 36 mm In distribution
DWE840 Outer Diameter 29 mm In distribution
DWE890 Outer Diameter 42 mm In distribution
DWD980 Outer Diameter 36 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Equinoxe Exactech, Inc. 442
Reunion Stryker GmbH 321
DJO Surgical Encore Medical, L.P. 266
SMR Shoulder Limacorporate 209
Tornier Flex Shoulder System Tornier Inc. 187
Anatomical Shoulder™ Zimmer, Inc. 166
Arthrex® Arthrex, Inc. 154
Comprehensive Shoulder System Biomet Orthopedics 111
Flex Shoulder System Tornier Inc. 109
Aequalis™ PerFORM+ Tornier Inc. 108
Aequalis™ Ascend™ Flex Tornier Inc. 102
Anatomic Shoulder Prosthesis Medacta International SA 90

Showing 12 of 326. All products under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K260721 2026-07-22
K191318 2019-06-14
K181420 2018-09-20
K160975 2016-06-10
K150583 2015-04-23
K121493 2012-06-20
K120794 2012-04-13
K113413 2012-03-09
K111902 2011-11-03
K110865 2011-04-27
K102924 2011-01-31
K103007 2010-11-09
K082120 2008-10-24
K081707 2008-07-17
K060209 2006-03-02
K043077 2004-12-17
K041339 2004-06-17
K032679 2003-12-15
K012212 2001-08-15
K003728 2000-12-20
K994393 2000-06-22
K994392 2000-03-10
K980244 1999-08-23
K952928 1995-09-27

Recalls

6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-03-05 Class II Labeling design Affected products were incorrectly labeled as Tornier HRS Max products. These parts are compatible with the Tornier HRS system only, and are incompatible with the Tornier HRS Max system. 233
2025-12-19 Class II Labeling mix-ups A specific lot of screws is incorrectly labeled. Screws are labeled as 5.0mmx18mm but actual screws are 5.00mmx14mm. If mismatch is detected during surgery, the issue may cause a minor delay in surgery. If not detected and incorrect screw i 427
2023-06-12 Class II Under Investigation by firm A comingle/swap resulted in the labeling and laser marking on the product to state it is a Aequalis Flex Revive Assembly Screw 0mm Standard (ARS655101) but it was a Aequalis Flex Revive Assembly Screw 0mm Short (ARS655118) & vice versa. 55 units
2023-06-12 Class II Under Investigation by firm A comingle/swap resulted in the labeling and laser marking on the product to state it is a Aequalis Flex Revive Assembly Screw 0mm Standard (ARS655101) but it was a Aequalis Flex Revive Assembly Screw 0mm Short (ARS655118) & vice versa. 55 units
2021-05-28 Class II Employee error Two lots have been swapped thus have the incorrect product in the package. The component may be of a different thickness. 20 2023-04-14
2016-09-19 Class II Component design/selection Tornier is conducting a recall on Aequalis Fx2 ( implant parts and instrument trays) due to reports of dislocations of the poly insert and the stem. 30 2018-05-31

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer