Ashcom™ Shoulder

5 catalogue numbers from 01.04441.006, listed by Zimmer, Inc., United States, under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented. 9 manufacturers in China are registered for this product code.

Registry build 21.09.26
9manufacturers in China registered for this device type
5catalogue numbers in this listing
7510(k) clearances naming this product code
20recalls on this code

Who Else Makes It

Concentrated in Jiangsu (5), Shanghai (3), Zhejiang (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KWS
Manufacturer City Province Registered as Device types
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
Stryker Trauson (Changzhou) Medical Technology Co., Ltd. Changzhou Jiangsu Contract manufacturer 3
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34

Record

Regulatory record for Ashcom™ Shoulder
Listed by Zimmer, Inc., United States
FDA product code KWS
Device type Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
Device class Class 2
Regulation 21 CFR 888.3660
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter
Record published 2017-07-27
Record revised 2021-07-14 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number, manufacturing date

Catalogue Numbers

Catalogue numbers for Ashcom™ Shoulder
Catalogue number Size Per pack Status
01.04441.006 In distribution
01.04441.009 In distribution
01.04441.008 In distribution
01.04441.001 2 In distribution
01.04441.004 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Equinoxe Exactech, Inc. 442
Reunion Stryker GmbH 321
DJO Surgical Encore Medical, L.P. 266
SMR Shoulder Limacorporate 209
Tornier Flex Shoulder System Tornier Inc. 187
Anatomical Shoulder™ Zimmer, Inc. 166
Arthrex® Arthrex, Inc. 154
Comprehensive Shoulder System Biomet Orthopedics 111
Flex Shoulder System Tornier Inc. 109
Aequalis™ PerFORM+ Tornier Inc. 108
Aequalis™ Ascend™ Flex Tornier Inc. 102
Anatomic Shoulder Prosthesis Medacta International SA 90

Showing 12 of 326. All products under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K193180 2020-02-24
K191814 2019-10-23
K160085 2016-03-08
K142403 2014-11-24
K062029 2006-10-31
K051623 2005-07-19
K870262 1987-04-03

Recalls

11 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2016-05-17 Class II Device Design In some cases it has been difficult or not possible to disassemble the adjusted Dome Centric from the AS Humeral Rasp after initial positioning of the AS Humeral Trial Head which resulted in the whole construct of the Dome Centric with the 177 2016-10-31
2012-09-04 Class II Error in labeling Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient 45 USA 2014-04-16
2012-09-04 Class II Error in labeling Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Wintetthur, Switzerland, after receiving four complaints of a discrepancy between product patient 228 2014-04-16
2012-09-04 Class II Error in labeling Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient 224 2014-04-16
2012-09-04 Class II Error in labeling Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Wintetthur, Switzerland, after receiving four complaints of a discrepancy between product patient 139 2014-04-16
2012-09-04 Class II Error in labeling Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient 66 2014-04-16
2012-09-04 Class II Error in labeling Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Wintetthur, Switzerland, after receiving four complaints of a discrepancy between product patient 26 2014-04-16
2012-09-04 Class II Error in labeling Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient 164 in USA 2014-04-16
2012-09-04 Class II Error in labeling Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient 74 2014-04-16
2012-09-04 Class II Error in labeling Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient 260 2014-04-16
2012-09-04 Class II Error in labeling Zimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product patient 54 2014-04-16
2007-06-25 Not classified Other The package actually contains a knee patellar implant. 10 2007-12-05
2005-08-23 Not classified Other The implant may fracture at the junction of the base and the trabecular metal keel if adequate support for the base has not been achieved by the host bone and/or bone cement. 2005-12-08
2005-08-23 Not classified Other The implant may fracture at the junction of the base and the trabecular metal keel if adequate support for the base has not been achieved by the host bone and/or bone cement. 2005-12-08
2005-08-23 Not classified Other The implant may fracture at the junction of the base and the trabecular metal keel if adequate support for the base has not been achieved by the host bone and/or bone cement. 2005-12-08
2005-08-23 Not classified Other The implant may fracture at the junction of the base and the trabecular metal keel if adequate support for the base has not been achieved by the host bone and/or bone cement. 2005-12-08
2005-08-23 Not classified Other The implant may fracture at the junction of the base and the trabecular metal keel if adequate support for the base has not been achieved by the host bone and/or bone cement. 2005-12-08
2005-08-23 Not classified Other The implant may fracture at the junction of the base and the trabecular metal keel if adequate support for the base has not been achieved by the host bone and/or bone cement. 2005-12-08
2005-08-23 Not classified Other The implant may fracture at the junction of the base and the trabecular metal keel if adequate support for the base has not been achieved by the host bone and/or bone cement. 2005-12-08
2005-08-23 Not classified Other The implant may fracture at the junction of the base and the trabecular metal keel if adequate support for the base has not been achieved by the host bone and/or bone cement. 2005-12-08

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.