Comprehensive

8 catalogue numbers from 405807, listed by Biomet Orthopedics, United States, under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented. 9 manufacturers in China are registered for this product code.

Registry build 21.09.26
9manufacturers in China registered for this device type
8catalogue numbers in this listing

Who Else Makes It

Concentrated in Jiangsu (5), Shanghai (3), Zhejiang (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KWS
Manufacturer City Province Registered as Device types
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
Stryker Trauson (Changzhou) Medical Technology Co., Ltd. Changzhou Jiangsu Contract manufacturer 3
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34

Record

Regulatory record for Comprehensive
Listed by Biomet Orthopedics, United States
FDA product code KWS
Device type Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
Device class Class 2
Regulation 21 CFR 888.3660
510(k) K120121
Record published 2016-10-27
Record revised 2026-02-09 (version 8)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date

Catalogue Numbers

Catalogue numbers for Comprehensive
Catalogue number Size Status
405807 MINI GLENOID BASEPLATE REAMER In distribution
405803 MINI GLENOID BASEPLATE PIN SIZER In distribution
SSI004997 Standard In distribution
405809 MINI GLENOID BASEPLATE IMPACTOR In distribution
SSI004999 In distribution
SSI004706 Medium In distribution
110003481 In distribution
SSI004992 Short Mini In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Equinoxe Exactech, Inc. 442
Reunion Stryker GmbH 321
DJO Surgical Encore Medical, L.P. 266
SMR Shoulder Limacorporate 209
Tornier Flex Shoulder System Tornier Inc. 187
Anatomical Shoulder™ Zimmer, Inc. 166
Arthrex® Arthrex, Inc. 154
Comprehensive Shoulder System Biomet Orthopedics 111
Flex Shoulder System Tornier Inc. 109
Aequalis™ PerFORM+ Tornier Inc. 108
Aequalis™ Ascend™ Flex Tornier Inc. 102
Anatomic Shoulder Prosthesis Medacta International SA 90

Showing 12 of 326. All products under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented

Recalls Naming This Product

10 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Comprehensive
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Biomet, Inc. 510(k) number 2021-01-15 Class II Labeling Change Control Zimmer Biomet is conducting a lot specific medical device recall for the Comprehensive Reverse Shoulder Central Screw, 25 MM Length. It has been determined through a complaint investigation that a 40 MM length central screw was packaged a 49 2023-03-09
Biomet, Inc. 510(k) number 2020-11-25 Class II Process control Specific lots of multiple sterile medical devices may have a breach in the sterile seal. A breach in the packaging seal could lead to loss of sterility of the device. 7428 2024-05-08
Biomet, Inc. 510(k) number 2020-09-02 Class II Packaging process control Product potentially being packaged without a taper adapter or baseplate. The package should contain one (1) baseplate and one (1) taper adapter, product may be packaged with two (2) baseplates and no (0) adapters or with no (0) baseplates a 3 units 2020-12-31
Biomet, Inc. 510(k) number 2020-02-25 Class II Packaging process control Package is intended to contain one (1) baseplate and one (1) taper adapter; however, devices may be packaged with two (2) baseplates and no (0) adapters. 21 units 2020-08-05
Biomet, Inc. 510(k) number 2018-12-21 Class II Packaging process control The product was potentially being packaged without a taper adapter. 52 2020-05-06
Biomet, Inc. 510(k) number 2017-04-26 Class II Under Investigation by firm Zimmer Biomet is conducting a voluntary recall for a single lot of the Modular Hybrid Glenoid Base Large for the Comprehensive Shoulder System after it was determined that two pieces from the lot were moved to finished goods and shipped des 16 2018-03-30
Biomet, Inc. 510(k) number 2017-02-17 Class II Process design Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components. 28,253 in total 2018-01-29
Biomet, Inc. 510(k) number 2015-01-07 Class II Process control The taper adaptor is missing from the packaging, which may result in a delay in surgery greater than 30 minutes. 11- 6 consumed, 5 with distributors 2015-10-22
Biomet, Inc. 510(k) number 2008-03-13 Not classified Device Design The glenoid implant may not seat fully on the face of the natural glenoid due to inadequate measurement tolerances (tolerance stack-up) in the design of the cutter. Use of the instrument may lead to incomplete seating of the glenoid implan 189 2008-10-15
Biomet, Inc. 510(k) number 0012-12-06 Class II Nonconforming Material/Component Biomet is recalling Part Number PT-113950 PT Hybrid Glenoid Post, following an investigation which identified that the male thread of the post may be oversized. This oversized condition can vary in degree and may lead to the following thre 1050 2013-11-08

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer