Glenoid IRI Leg (24mm)
The Glenoid IRI Leg (24mm) is a component of the Glenoid Intelligent Reusable Instrument (IRI). The Glenoid IRI Leg (24mm) is indicated for use as part of the Arthrex Glenoid Intelligent…
The Glenoid IRI Leg (24mm) is a component of the Glenoid Intelligent Reusable Instrument (IRI). The Glenoid IRI Leg (24mm) is indicated for use as part of the Arthrex Glenoid Intelligent Reusable Instrument System (IRIS) for Total Shoulder Arthroplasty (TSA).
Who Else Makes It
Concentrated in Jiangsu (5), Shanghai (3), Zhejiang (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 10 |
| Stryker Trauson (Changzhou) Medical Technology Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 3 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
Record
| Listed by | Custom Orthopaedic Solutions, Inc., United States |
|---|---|
| FDA product code | KWS |
| Device type | Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3660 |
| Record published | 2016-09-02 |
| Record revised | 2024-03-12 (version 7) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Prescription | Prescription only |
| Label carries | lot or batch number |
| Storage | Special storage condition: Store in a dry, dark, cool place |
| Sizes | Length 24 mm |
| Distribution end date | 2019-06-21 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| L | Length 24 mm | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Equinoxe | Exactech, Inc. | 442 |
| Reunion | Stryker GmbH | 321 |
| DJO Surgical | Encore Medical, L.P. | 266 |
| SMR Shoulder | Limacorporate | 209 |
| Tornier Flex Shoulder System | Tornier Inc. | 187 |
| Anatomical Shoulder™ | Zimmer, Inc. | 166 |
| Arthrex® | Arthrex, Inc. | 154 |
| Comprehensive Shoulder System | Biomet Orthopedics | 111 |
| Flex Shoulder System | Tornier Inc. | 109 |
| Aequalis™ PerFORM+ | Tornier Inc. | 108 |
| Aequalis™ Ascend™ Flex | Tornier Inc. | 102 |
| Anatomic Shoulder Prosthesis | Medacta International SA | 90 |
Showing 12 of 326. All products under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K162697 | 2017-02-10 |
| K153215 | 2016-02-19 |
| K151500 | 2015-10-05 |
| K142072 | 2014-11-24 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.