Instrument

Specialty Reunion RSA Baseplate Centering Guide Assy

Registry build 21.09.26
9manufacturers in China registered for this device type
6catalogue numbers in this listing
4510(k) clearances naming this product code
5recalls on this code

Who Else Makes It

Concentrated in Jiangsu (5), Shanghai (3), Zhejiang (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KWS
Manufacturer City Province Registered as Device types
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
Stryker Trauson (Changzhou) Medical Technology Co., Ltd. Changzhou Jiangsu Contract manufacturer 3
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34

Record

Regulatory record for Instrument
Listed by Howmedica Osteonics Corp, United States
FDA product code KWS
Device type Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
Device class Class 2
Regulation 21 CFR 888.3660
Establishment Contract manufacturer, Contract steriliser, Specification developer, Manufacturer
Premarket notification Exempt
Record published 2016-09-24
Record revised 2023-08-09 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Instrument
Catalogue number Size Status
I-U0252GR32 Diameter: 32.0 Millimeter In distribution
I-U0257GR28 Diameter: 28.0 Millimeter In distribution
I-U0252GR36 Diameter: 36.0 Millimeter In distribution
I-U0262CG0L Side: LEFT In distribution
I-U0252GR40 Diameter: 40.0 Millimeter In distribution
I-U0262CG0R Side: RIGHT In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Equinoxe Exactech, Inc. 442
Reunion Stryker GmbH 321
DJO Surgical Encore Medical, L.P. 266
SMR Shoulder Limacorporate 209
Tornier Flex Shoulder System Tornier Inc. 187
Anatomical Shoulder™ Zimmer, Inc. 166
Arthrex® Arthrex, Inc. 154
Comprehensive Shoulder System Biomet Orthopedics 111
Flex Shoulder System Tornier Inc. 109
Aequalis™ PerFORM+ Tornier Inc. 108
Aequalis™ Ascend™ Flex Tornier Inc. 102
Anatomic Shoulder Prosthesis Medacta International SA 90

Showing 12 of 326. All products under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K103835 2011-05-05
K103104 2010-11-22
K062113 2006-10-03
K990598 1999-03-15

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-07-30 Not classified Process change control Affected devices were manufactured with Ultra High Molecular Weight Polyethylene (UHMWPE) raw material aged in excess of five years. Product has the potential for elevated levels of oxidation, which may result in increased wear, leading to 12,156 US
2015-05-12 Class II Process control A package labeled as Part #5901-S-4818, Lot MAC7C14, standard humeral head trial, contained part # 5901-E-4818 Lot MAC7C14, offset humeral head trial. 21 units 2016-10-05
2008-11-13 Not classified Packaging Stryker Orthopaedics became aware of a visual defect in certain blister packages of certain devices. 322 total units – all types 2010-01-20
2007-11-15 Not classified Process control Delamination: Loosening of the titanium plasma coating on the product was observed on twelve non-distributed units. 915 units 2010-01-25
2007-05-09 Not classified Process control The plasma spray may delaminate from the proximal portion of the humeral stem. 232 units 2008-03-07

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer