Tornier Perform® Reversed Augmented Glenoid
6 catalogue numbers from DWJ502, listed by Tornier Inc., United States, under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented. 9 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (5), Shanghai (3), Zhejiang (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 10 |
| Stryker Trauson (Changzhou) Medical Technology Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 3 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
Record
| Listed by | Tornier Inc., United States |
|---|---|
| FDA product code | KWS |
| Device type | Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3660 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2022-05-10 |
| Record revised | 2025-04-10 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | expiry date, manufacturing date, serial number |
| Sizes | Outer diameter 25 to 29 mm; angle 15 to 35 ° |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| DWJ502 | Outer Diameter 25 mm | In distribution |
| DWJ515 | Angle 15 ° | In distribution |
| DWJ514 | Angle 35 ° | In distribution |
| DWJ504 | Outer Diameter 25 mm | In distribution |
| DWJ503 | Outer Diameter 25 mm | In distribution |
| DWJ513 | Outer Diameter 29 mm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Equinoxe | Exactech, Inc. | 442 |
| Reunion | Stryker GmbH | 321 |
| DJO Surgical | Encore Medical, L.P. | 266 |
| SMR Shoulder | Limacorporate | 209 |
| Tornier Flex Shoulder System | Tornier Inc. | 187 |
| Anatomical Shoulder™ | Zimmer, Inc. | 166 |
| Arthrex® | Arthrex, Inc. | 154 |
| Comprehensive Shoulder System | Biomet Orthopedics | 111 |
| Flex Shoulder System | Tornier Inc. | 109 |
| Aequalis™ PerFORM+ | Tornier Inc. | 108 |
| Aequalis™ Ascend™ Flex | Tornier Inc. | 102 |
| Anatomic Shoulder Prosthesis | Medacta International SA | 90 |
Showing 12 of 326. All products under Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K260721 | 2026-07-22 |
| K191318 | 2019-06-14 |
| K181420 | 2018-09-20 |
| K160975 | 2016-06-10 |
| K150583 | 2015-04-23 |
| K121493 | 2012-06-20 |
| K120794 | 2012-04-13 |
| K113413 | 2012-03-09 |
| K111902 | 2011-11-03 |
| K110865 | 2011-04-27 |
| K102924 | 2011-01-31 |
| K103007 | 2010-11-09 |
| K082120 | 2008-10-24 |
| K081707 | 2008-07-17 |
| K060209 | 2006-03-02 |
| K043077 | 2004-12-17 |
| K041339 | 2004-06-17 |
| K032679 | 2003-12-15 |
| K012212 | 2001-08-15 |
| K003728 | 2000-12-20 |
| K994393 | 2000-06-22 |
| K994392 | 2000-03-10 |
| K980244 | 1999-08-23 |
| K952928 | 1995-09-27 |
Recalls Naming This Product
1 recall names this product by its own identifier, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Tornier Inc. | UDI-DI | 2023-09-15 | Class II | Process change control | One lot of Tournier Perform Reversed Lateralized Baseplates were found to have been manufactured with 6mm spacers instead of 3mm spacers. This nonconformance prevents the central screw from being able to thread into the baseplate. | 30 units |
Recalls
6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2026-03-05 | Class II | Labeling design | Affected products were incorrectly labeled as Tornier HRS Max products. These parts are compatible with the Tornier HRS system only, and are incompatible with the Tornier HRS Max system. | 233 | |
| 2025-12-19 | Class II | Labeling mix-ups | A specific lot of screws is incorrectly labeled. Screws are labeled as 5.0mmx18mm but actual screws are 5.00mmx14mm. If mismatch is detected during surgery, the issue may cause a minor delay in surgery. If not detected and incorrect screw i | 427 | |
| 2023-06-12 | Class II | Under Investigation by firm | A comingle/swap resulted in the labeling and laser marking on the product to state it is a Aequalis Flex Revive Assembly Screw 0mm Standard (ARS655101) but it was a Aequalis Flex Revive Assembly Screw 0mm Short (ARS655118) & vice versa. | 55 units | |
| 2023-06-12 | Class II | Under Investigation by firm | A comingle/swap resulted in the labeling and laser marking on the product to state it is a Aequalis Flex Revive Assembly Screw 0mm Standard (ARS655101) but it was a Aequalis Flex Revive Assembly Screw 0mm Short (ARS655118) & vice versa. | 55 units | |
| 2021-05-28 | Class II | Employee error | Two lots have been swapped thus have the incorrect product in the package. The component may be of a different thickness. | 20 | 2023-04-14 |
| 2016-09-19 | Class II | Component design/selection | Tornier is conducting a recall on Aequalis Fx2 ( implant parts and instrument trays) due to reports of dislocations of the poly insert and the stem. | 30 | 2018-05-31 |