Active Articulation
2 catalogue numbers from 010000991, listed by Biomet Orthopedics, United States, under Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented. 14 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (7), Shanghai (3), Zhejiang (2). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Lincotek (Wuxi) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 7 |
| b-ONE Medical (Beijing) Co., Ltd. | Beijing | Beijing | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented
Record
| Listed by | Biomet Orthopedics, United States |
|---|---|
| FDA product code | KWY |
| Device type | Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3390 |
| 510(k) | K110555 |
| Record published | 2020-05-15 |
| Record revised | 2025-05-30 (version 8) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 010000991 | 22.2mm Head Size 36mm Bearing Size B | In distribution |
| 31-139273 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Resolve Modular Revision Hip Stem | United Orthopedic Corp. | 196 |
| Corin Bipolar Prosthesis | Corin Limited | 182 |
| Consensus® Hip System | Consensus Orthopedics, Inc. | 177 |
| Consensus Hip System | Shalby Advanced Technologies, Inc. | 177 |
| Instrument | Howmedica Osteonics Corp | 130 |
| Bencox Hip System | Corentec Co., Ltd. | 126 |
| United Hip System, U2 Bipolar Implant | United Orthopedic Corp. | 123 |
| MultiPolar® | Zimmer, Inc. | 100 |
| Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented | Zimmer, Inc. | 96 |
| Fitmore® Hip Stem | Zimmer, Inc. | 75 |
| Arcos® Modular Revision System | Biomet Orthopedics | 67 |
| Acumatch L-Series | Exactech, Inc. | 67 |
Showing 12 of 352. All products under Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Biomet, Inc. | 510(k) number | 2023-02-06 | Class II | Under Investigation by firm | The outer package labeling and product etch are a 40 mm Size D liner, however, the implant is a 38 mm Size C liner. | 12 units | |
| Biomet, Inc. | 510(k) number | 2016-12-19 | Class II | Under Investigation by firm | Product complaints indicated that the part and lot numbers on the packaging differed from the physical product inside the packaging. Risk of delay in surgery. | 36 | 2017-09-19 |
| Biomet, Inc. | 510(k) number | 2016-12-19 | Class II | Under Investigation by firm | Product complaints indicated that the part and lot numbers on the packaging differed from the physical product inside the packaging. Risk of delay in surgery. | 19 | 2017-09-19 |
| Biomet, Inc. | 510(k) number | 2013-04-26 | Class II | Labeling mix-ups | Biomet is recalling Active Articulation E1 Hip Bearing implants. Biomet has initiated this action following an investigation which identified that outer label indicates two conflicting O.D. sizes while the inner labels indicate an incorrec | 8 units | 2013-08-29 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.