C-Taper Head
7 catalogue numbers from 06-3299, listed by Howmedica Osteonics Corp, United States, under Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented. 14 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (7), Shanghai (3), Zhejiang (2). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Lincotek (Wuxi) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 7 |
| b-ONE Medical (Beijing) Co., Ltd. | Beijing | Beijing | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented
Record
| Listed by | Howmedica Osteonics Corp, United States |
|---|---|
| FDA product code | KWY |
| Device type | Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3390 |
| Establishment | Contract manufacturer, Contract steriliser, Specification developer, Manufacturer |
| 510(k) | K910988 |
| Record published | 2015-09-24 |
| Record revised | 2024-05-30 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 06-3299 | Diameter: 32.0 Millimeter | In distribution |
| 6001-2600 | Offset: 0.0 Millimeter | In distribution |
| 06-2605 | Diameter: 26.0 Millimeter | In distribution |
| 6001-2800 | Offset: 0.0 Millimeter | In distribution |
| 06-3210 | Diameter: 32.0 Millimeter | In distribution |
| 06-2210 | Diameter: 22.0 Millimeter | In distribution |
| 6001-3299 | Offset: -5.0 Millimeter | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Resolve Modular Revision Hip Stem | United Orthopedic Corp. | 196 |
| Corin Bipolar Prosthesis | Corin Limited | 182 |
| Consensus® Hip System | Consensus Orthopedics, Inc. | 177 |
| Consensus Hip System | Shalby Advanced Technologies, Inc. | 177 |
| Instrument | Howmedica Osteonics Corp | 130 |
| Bencox Hip System | Corentec Co., Ltd. | 126 |
| United Hip System, U2 Bipolar Implant | United Orthopedic Corp. | 123 |
| MultiPolar® | Zimmer, Inc. | 100 |
| Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented | Zimmer, Inc. | 96 |
| Fitmore® Hip Stem | Zimmer, Inc. | 75 |
| Arcos® Modular Revision System | Biomet Orthopedics | 67 |
| Acumatch L-Series | Exactech, Inc. | 67 |
Showing 12 of 352. All products under Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Howmedica Osteonics Corp | 510(k) number | 2009-06-18 | Not classified | Process control | Sterilization issue: During post-sterilization inspection of the outer blister packaging of the affected lots, it was determined that the outer blister did not meet the required minimum seal width. | 13 total, both products. | 2012-08-27 |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2005-11-08 | Not classified | Employee error | Mislabeled boxes — Scorpio PS Right Femoral Component No Posts contained a Scorpio PS Left Femoral Component with Posts and vice versa. | 8 units | 2010-05-13 |