DJO Surgical

HIP, Stem, CLP, Revision, SIZE#11, Implant, Polished Neck

Registry build 21.09.26
14manufacturers in China registered for this device type
30catalogue numbers in this listing
18recalls on this code

Who Else Makes It

Concentrated in Jiangsu (7), Shanghai (3), Zhejiang (2). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KWY
Manufacturer City Province Registered as Device types
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
Lincotek (Wuxi) Co., Ltd. Wuxi Jiangsu Contract manufacturer 7
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70

Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented

Record

Regulatory record for DJO Surgical
Listed by Encore Medical, L.P., United States
FDA product code KWY
Device type Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented
Device class Class 2
Regulation 21 CFR 888.3390
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer
510(k) K953510
Record published 2017-08-07
Record revised 2020-09-09 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Latex Labelled latex-free
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for DJO Surgical
Catalogue number Size Status
412-02-049 In distribution
412-02-044 In distribution
412-02-042 In distribution
425-92-017 In distribution
425-92-005 In distribution
425-93-011 In distribution
425-92-013 In distribution
412-02-046 In distribution
412-02-047 In distribution
412-02-053 In distribution
412-02-064 In distribution
425-93-021 In distribution
412-02-060 In distribution
412-02-052 In distribution
412-02-043 In distribution
412-02-056 In distribution
412-02-062 In distribution
425-93-012 In distribution
425-91-004 In distribution
425-93-009 In distribution
412-02-040 In distribution
425-92-007 In distribution
412-02-050 In distribution
412-02-051 In distribution
425-93-014 In distribution
412-02-054 In distribution
426-12-110 In distribution
412-02-045 In distribution
412-02-048 In distribution
412-02-058 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Resolve Modular Revision Hip Stem United Orthopedic Corp. 196
Corin Bipolar Prosthesis Corin Limited 182
Consensus® Hip System Consensus Orthopedics, Inc. 177
Consensus Hip System Shalby Advanced Technologies, Inc. 177
Instrument Howmedica Osteonics Corp 130
Bencox Hip System Corentec Co., Ltd. 126
United Hip System, U2 Bipolar Implant United Orthopedic Corp. 123
MultiPolar® Zimmer, Inc. 100
Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented Zimmer, Inc. 96
Fitmore® Hip Stem Zimmer, Inc. 75
Arcos® Modular Revision System Biomet Orthopedics 67
Acumatch L-Series Exactech, Inc. 67

Showing 12 of 352. All products under Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented

Recalls Naming This Product

19 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of DJO Surgical
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Encore Medical, L.P. 510(k) number 2023-08-04 Class II Nonconforming Material/Component Orthopedic device components were not subjected to final sterilization before shipment, which if implanted may lead to varying degrees of infection, which may require treatment, prolonged monitoring, and may lead to revision surgery 0
Encore Medical, L.P. 510(k) number 2007-08-02 Not classified Packaging change control Device mislabeled. Hip prosthesis components validated for 5 years were labeled as having a 6 year expiration date. 76 units. 2008-01-09
Encore Medical, L.P. 510(k) number 2007-08-02 Not classified Packaging change control Device mislabeled. Hip prosthesis components validated for 5 years were labeled as having a 6 year expiration date. 111 units. 2008-01-09
Encore Medical, L.P. 510(k) number 2007-08-02 Not classified Packaging change control Device mislabeled. Hip prosthesis components validated for 5 years were labeled as having a 6 year expiration date. 382 units. 2008-01-09
Encore Medical, L.P. 510(k) number 2007-08-02 Not classified Packaging change control Device mislabeled. Hip prosthesis components validated for 5 years were labeled as having a 6 year expiration date. 479 units. 2008-01-09
Encore Medical, L.P. 510(k) number 2007-08-02 Not classified Packaging change control Device mislabeled. Hip prosthesis components validated for 5 years were labeled as having a 6 year expiration date. 776 units. 2008-01-09
Encore Medical, L.P. 510(k) number 2007-08-02 Not classified Packaging change control Device mislabeled; hip prosthesis components validated for 5 years were labeled as having a 6 year expiration date. 632 units. 2008-01-09
Encore Medical, L.P. 510(k) number 2007-08-02 Not classified Packaging change control Device mislabeled; hip prosthesis components validated for 5 years were labeled as having a 6 year expiration date. 605 units. 2008-01-09
Encore Medical, L.P. 510(k) number 2007-08-02 Not classified Packaging change control Device mislabeled; hip prosthesis components validated for 5 years were labeled as having a 6 year expiration date. 478 units. 2008-01-09
Encore Medical, L.P. 510(k) number 2007-08-02 Not classified Packaging change control Device mislabeled; hip prosthesis components validated for 5 years were labeled as having a 6 year expiration date. 377 units. 2008-01-09
Encore Medical, L.P. 510(k) number 2007-08-02 Not classified Packaging change control Device mislabeled; hip prosthesis components validated for 5 years were labeled as having a 6 year expiration date. 304 units. 2008-01-09
Encore Medical, L.P. 510(k) number 2007-08-02 Not classified Packaging change control Device mislabeled; hip prosthesis components validated for 5 years were labeled as having a 6 year expiration date. 225 units. 2008-01-09
Encore Medical, L.P. 510(k) number 2007-08-02 Not classified Packaging change control Device mislabeled; hip prosthesis components validated for 5 years were labeled as having a 6 year expiration date. 185 units. 2008-01-09
Encore Medical, L.P. 510(k) number 2007-08-02 Not classified Packaging change control Device mislabeled; hip prosthesis components validated for 5 years were labeled as having a 6 year expiration date. 171 units. 2008-01-09
Encore Medical, L.P. 510(k) number 2007-08-02 Not classified Packaging change control Device mislabeled; hip prosthesis components validated for 5 years were labeled as having a 6 year expiration date. 137 units. 2008-01-09
Encore Medical, L.P. 510(k) number 2007-08-02 Not classified Packaging change control Device mislabeled; hip prosthesis components validated for 5 years were labeled as having a 6 year expiration date. 137 units. 2008-01-09
Encore Medical, L.P. 510(k) number 2007-08-02 Not classified Packaging change control Device mislabeled; hip prosthesis components validated for 5 years were labeled as having a 6 year expiration date. 86 units. 2008-01-09
Encore Medical, L.P. 510(k) number 2007-08-02 Not classified Packaging change control Device mislabeled; hip prosthesis components validated for 5 years were labeled as having a 6 year expiration date. 2008-01-09
Encore Medical, L.P. 510(k) number 2007-08-02 Not classified Packaging change control Device mislabeled; hip prosthesis components validated for 5 years were labeled as having a 6 year expiration date. 13 units. 2008-01-09

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer