Echo® Bi-Metric® Hip System
11 catalogue numbers from 192119, listed by Biomet Orthopedics, United States, under Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented. 14 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (7), Shanghai (3), Zhejiang (2). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Lincotek (Wuxi) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 7 |
| b-ONE Medical (Beijing) Co., Ltd. | Beijing | Beijing | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented
Record
| Listed by | Biomet Orthopedics, United States |
|---|---|
| FDA product code | KWY |
| Device type | Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3390 |
| 510(k) | K070274 |
| Record published | 2018-07-23 |
| Record revised | 2025-05-30 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 192119 | 19 Size 175 mm Type I Taper | In distribution |
| 192107 | 7 SIZE 115 MM TYPE I TAPER | In distribution |
| 192508 | 8 SIZE 120 MM TYPE I TAPER | In distribution |
| 192408 | 8 SIZE 120 MM TYPE I TAPER | In distribution |
| 192417 | 17 SIZE 165 MM TYPE I TAPER | In distribution |
| 192416 | 16 SIZE 160 MM TYPE I TAPER | In distribution |
| 110025753 | SIZE 11 TO 14 | In distribution |
| 192115 | 15 Size 155 mm Type I Taper | In distribution |
| 192513 | 13 SIZE 145 MM TYPE I TAPER | In distribution |
| 192408 | 8 Size 120 mm Type I Taper | In distribution |
| 192114 | 14 Size 150 mm Type I Taper | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Resolve Modular Revision Hip Stem | United Orthopedic Corp. | 196 |
| Corin Bipolar Prosthesis | Corin Limited | 182 |
| Consensus® Hip System | Consensus Orthopedics, Inc. | 177 |
| Consensus Hip System | Shalby Advanced Technologies, Inc. | 177 |
| Instrument | Howmedica Osteonics Corp | 130 |
| Bencox Hip System | Corentec Co., Ltd. | 126 |
| United Hip System, U2 Bipolar Implant | United Orthopedic Corp. | 123 |
| MultiPolar® | Zimmer, Inc. | 100 |
| Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented | Zimmer, Inc. | 96 |
| Fitmore® Hip Stem | Zimmer, Inc. | 75 |
| Arcos® Modular Revision System | Biomet Orthopedics | 67 |
| Acumatch L-Series | Exactech, Inc. | 67 |
Showing 12 of 352. All products under Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented
Recalls Naming This Product
3 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Biomet, Inc. | 510(k) number | 2018-06-08 | Class II | Process control | Two lots of the Echo BI-Metric Hip Stem and ARCOS Modular Revision Hip Stem may have been comingled. Potential health consequences include extension of surgery time to find a replacement component. | 12 | 2020-04-14 |
| Biomet, Inc. | 510(k) number | 2017-06-05 | Class II | Labeling False and Misleading | Possibility that the patient label inside the product box was incorrectly labeled. The outer box label and actual product are correctly identified but the internal patient label could be incorrect. | 2018-03-06 | |
| Biomet, Inc. | 510(k) number | 2012-11-06 | Class II | Labeling Change Control | It was reported that the surgeon noticed that the Echo 11mm hip stem had an etching indicating it was 13mm stem. | 4 | 2013-08-28 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.